REPORT No.SZ21020185W03
2.9.3. Test Result
According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than
amplitudes measured with the quasi-peak (or average) detector, the measurement data from a
spectrum analyzer peak detector will represent the worst-case results, if the peak measured value
complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak
measurement (or average).
The measurement results are obtained as below:
E [dBμV/m] =U
R
+ A
T
+ A
Factor
[dB]; A
T
=L
Cable loss
[dB]-G
preamp
[dB]
A
T
: Total correction Factor except Antenna
U
R
: Receiver Reading
G
preamp
: Preamplifier Gain
A
Factor
: Antenna Factor at 3m
During the test, the total correction Factor A
T
and A
Factor
were built in test software.
Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis
test condition was recorded in this test report.
Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result
which was 20dB lower than the limit was not recorded.
Note3: For the frequency, which started from 18GHz to 40GHz, was pre-scanned and the result
which was 20dB lower than the limit was not recorded.