Installation Manual

Redpine Signals, Inc. Proprietary and Confidential Page 11
User
Manual
Version 2.0.0
<start/stop>: Parameter to start or stop logging the statistics. Enter 0 to
start logging and 1 to stop logging.
<channel_width>: Operating bandwidth of the channel.
2.2.3 Examples
# ./receive stats 6 0 0
The above command starts the receive utility and logs statistics with the
following parameters.
Filename stats
Channel number – 6
Channel Width – 20MHz
The test utility displays the following information:
Total number of packets received with correct CRC.
Total number of packets received with incorrect CRC.
Total number of False CCA’s received.
# ./receive stats 6 1 0
The above command will stop the receive application