REDRING ACTIVE 350S SMART TECHNOLOGY ELECTRIC SHOWER Installation and User Guide IMPORTANT: This booklet should be left with the user after installation and demonstration
CONTENTS Section Page Introduction _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 Important Safety Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 How to use your Active 350S Shower (Detailed) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 How your Active 350S Shower Works _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 How to maintain your Active 350S Shower _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5 What to do if thin
HOW TO USE YOUR ACTIVE 350S SHOWER (DETAILED) 1. Ensure the electricity and water are turned on to the unit. 2. Your shower has 3 power settings selected by turning outer knob “A”. The most popular is “ (high)”. There are also options for a “ or “ (medium)” (cold)” shower (see notes 8 and 9). For this example turn outer knob “A” to “ and set inner knob “B” to “12 o’clock”. (high) ” 3. The water will flow and the neon light will glow brightly. 4.
HOW YOUR ACTIVE 350S SHOWER WORKS 1. Water is heated instantaneously as it flows over the heating elements in the copper cylinder (diagram 2). 2. The heaters are only switched on when sufficient water is flowing. This is done automatically with a switch which works on water pressure and is indicated by the neon light illuminating depending on the power selected by outer knob “A”. 3. The water is turned on and off by the solenoid valve built into the shower.
HOW TO MAINTAIN YOUR ACTIVE 350S SHOWER It is recommended that the shower unit and hose etc. be cleaned using a soft cloth and that the use of abrasive or solvent cleaning fluid be avoided. We recommend that before any cleaning, the isolating switch be turned off, thus avoiding accidentally switching on the shower.
WHAT TO DO IF THINGS GO WRONG (2) PROFESSIONAL SERVICE If the previous “Self Help” checks fail to restore the performance, you should seek professional help. The person who installed the shower is probably the best one to repair it and is certainly the person to contact if you have had a problem in the guarantee period. The following additional checklist is provided for the benefit of the qualified service person.
HOW TO INSTALL YOUR ACTIVE 350S SHOWER WARNING: ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A SUITABLY QUALIFIED PERSON. WARNING: DO NOT INSTALL THIS SHOWER WHERE IT MAY BE SUBJECTED TO FREEZING CONDITIONS We recommend that the installation is done in the following sequence. a. Fixing the shower to the wall b. Plumbing c. Electrical connections a. FIXING THE SHOWER TO THE WALL 1.
7. If you have not yet done so, remove the front cover assembly by undoing the retaining screws at the top and bottom of the unit and lifting the cover off. Your shower is provided with 2 fixing positions in the backplate (see diagram 4). The top-fixing hole is a “key-hole” slot (another key-hole is provided for alternate fixing), and should be marked and drilled first. Tighten top screw with head protruding about 10mm from the wall and hook the backplate over the screw head.
c) ELECTRICAL WARNING: THIS SHOWER MUST BE EARTHED. The electrical installation must be in accordance with the current BS.7671 (IEE Wiring Regulations) and “Part P” of the Building Regulations and/or local regulations 1. The SHOWER is designed for a single phase AC electrical supply. Please check the rating plate on the unit to see what details apply to your unit. AS A GUIDE ONLY (* Only applies if external earth impedance is less than 0.35 Ohms) Rating 7.2 / 6.6kW 240 / 230V . 8.5 / 7.8kW 240 / 230V 9.
5. Re-Fit the front cover (see diagram 9) a. Ensure outer knob “A” is aligned fully anti-clockwise to the “ (stop)” position. b. Ensure inner knob “B” is aligned fully to the “ (medium)” position. c. In the main body of the shower, turn the “Drive Spider” fully anti-clockwise until it stops. d. In the main body of the shower, turn the “Drive Gite” until it is at “3 o’clock”. e.
: GUARANTEE AND CONTACT DETAILS Full details of terms and conditions are available on request from:- APPLIED ENERGY PRODUCTS LIMITED MORLEY WAY, PETERBOROUGH PE2 9JJ TEL: +44 (0) 1733 456789 FAX: +44 (0) 1733 310606 Website: www.redring.co.
HOW TO USE YOUR ACTIVE 350S SHOWER (SUMMARY) 1. Ensure the electricity and water are turned on to the unit. 2. Turn outer knob “A” clockwise to the “Power Select” position of your choice. The water will flow, and the neon indicator light will glow. = High Power = Medium Power = Cold Shower 3. Turn inner knob “B” a small amount until you reach the desired showering temperature. Turn anti-clockwise (follow blue arrows) for cooler. Turn clockwise (follow red arrows) for warmer. 4.