Product Manual
Series L 3000 Spring Driven Cord Reels
www.reelcraft.com
Page 3
Replacing the Output Electrical Cord/Work
Device
WARNING: Use extreme caution, reel under tension. Avoid
releasing latch mechanism.
1. Pull output electrical cord from reel until fully extended,
then latch.
2. Remove output electrical bumper stop (7).
3. Disconnect output electrical cord / work device (12) at ter-
minal strip (10).
4. Remove strain relief (8). Remove output electrical cord /
work device.
5. Install replacement electrical cord / work device by revers-
ing steps 2 through 4.
6. Release latch and rewind electrical cord on reel.
7. Replace access cover (1).
Replacing the Input Electrical Cord
1. Remove wire nuts (15) securing input electrical cord to
collector assembly (13).
2. Remove 90 degree elbow (9).
3. Remove input electrical cord.
4. Remove 11” of outer jacket from replacement input electri-
cal cord (input electrical cord wires must protrude a mini-
mum of 6” from center of collector assembly).
5. Install replacement input electrical cord by reversing steps
1 through 3.
6. Replace access cover (1).
Replacing the Brush Holder/Brushes
1. At terminal strip (10), remove wires connecting brushes
(11) to terminal strip.
2. Remove lock nuts (3) securing brush holder (6) to reel.
Relocate cable clamp temporarily and remove brush holder.
3. Remove brushes (4) from brush holder (6).
4. Install replacement brush holder / brushes by reversing
steps 1 through 3. Upon completion of installation, adjust
brush-to-ring alignment by loosening nuts (5) and sliding
finger assembly (2).
Replacing the Collector Assembly
1. Remove wire nuts (15) securing input electrical cord to
collector assembly.
2. At terminal strip (10), disconnect wires (11) connecting
brushes (4) to terminal strip.
3. Remove lock nuts (3) securing brush holder (6) to reel.
Relocate cable clamp temporarily and remove brush holder.
4. Remove snap ring (14).
5. Remove collector assembly (13).
6. Install replacement collector assembly by reversing steps 1
through 5. Upon completion of installation, adjust brush-
to-ring alignment by loosening nuts (5) and sliding finger
assembly (2).
7. Replace access cover (1).
10
11
12
13
14
15
7
1
2
3
4
5
6
8
9