Residential DIY Applications

Recommended Products:
Double Reflective/Bubble Insulation - BP48025 (48”x 25’)
Installation Instructions:
Make sure all metal joints, seams and penetrations are sealed.
In order to obtain the R-6-0, a 3/4” air space (spacer strip) is required between the Reflectix
®
Reflective/Bubble/Bubble/Reflective product and the duct surface. A spacer strip can be created by
cutting Reflectix
®
into 2” wide strips and double wrapping (the strips) around the circumference of the
duct every 24”.
Verify the circumference of the duct at the mid-point of a spacer strip.
Cut the Reflectix
®
product to this length plus 2”.
Wrap the product around the duct and securely tape the linear and circumference seams (overlapping
1”- 2”) with a UL 181 Tape (goal is an air-tight, snug seam seal).
Do not leave any exposed duct or space where air can enter between the duct and the Reflectix
®
.
1. Reflectix
®
Insulation
2. Reflectix
®
Insulation
Spacer Strips
3. UL 181 Tape
4. Duct
Tools Required:
Safety Glasses
Tape Measure
Utility Knife/Scissors