Pro Residential, Post Frame and Metal Building Applications

Recommended Products:
Reflective/Bubble/Bubble/Reflective - Roll: BP24025 (24”x 25’)
Staple Tab, Reflective/Bubble/Bubble/Reflective - Roll: ST16025 (16”x 25’)
Installation Instructions: (There are 2 methods with varying levels of benefit)
1. Product Installed in the Back of the Knee Wall Cavity - R-16 and a Radiant Reflector (with R-13 Fiberglass
Batt)
Construct Knee Wall per Building Code.
Prior to installing fiberglass batts, measure the inside height of the knee wall cavity.
Precut the Reflectix
®
to this measured length minus 1/2”.
Start at the inside top of the first cavity.
If utilizing the Reflective/Bubble/Bubble/Reflective product, staple the tab of the product to the side
(back corner) of the stud and continue downward stapling every 3” to 4” - Repeat on opposite stud -
The plane created by the product should be parallel to the back side faces of the studs - There should
be a continuous 1/2” air gap across the bottom of the cavity.
Install Fiberglass Batt per Manufacturer’s Instructions.
1. Reflectix
®
Insulation
2. R-13 Fiberglass Batt
3. Vapor Barrier
(Polyethylene)
if Code Required
4. Interior Panel
(Sheetrock)
Tools Required:
Safety Glasses
Staple Gun
Tape Measure
Utility Knife/Scissors
Knee Wall| (R-16, R-19)
Reflectix
®
Installation Instructions
4
1
2
3