Pro Residential, Post Frame and Metal Building Applications
Recommended Products:
Staple Tab, Reflective/Bubble/Bubble/Reflective - Roll: ST16025 (16”x 25’)
Installation Instructions: (There are 3 “levels of benefit” options)
1. R-3.7 (1”x 2” nominal furring)
• Attach 1”x 2” (nominal) furring strips vertically at an interval of 16” on center to the masonry wall
(with an adhesive or fastener that is specified for this application).
• Cut the Reflectix
®
Reflective/Bubble/Bubble/Reflective, Staple Tab product (using scissors or a utility
knife) into lengths equal to the height of the wall (floor to ceiling).
• Staple the product to the face of the furring strip - product seams should split on a furring strip.
• One air space is created between the Reflectix
®
and the masonry wall.
• Finish with interior panel (or sheetrock) of choice.
2. R-4.2 (2”x 2” nominal furring)
• Same as above except utilize 2”x 2” (nominal) furring.
1. Reflectix
®
Insulation
2. 1”x 2” (nominal)
Furring Strip
3. Concrete Block Wall
Tools Required:
Safety Glasses
Staple Gun
Tape Measure
Utility Knife/Scissors
Wall - Masonry| (R-3.7, R-4.2, R-6.1)
Reflectix
®
Installation Instructions
1
3
2