Installation Guide

Recommended Products:
Reflective/Bubble/Bubble/Reflective - Roll: BP24025 (24”x 25’)
Staple Tab, Reflective/Bubble/Bubble/Reflective - Roll: ST16025 (16”x 25’), ST24025 (24”x 25’)
Installation Instructions:
Install R-19, un-faced, per manufacturer’s specifications.
Place one corner edge of the Reflectix
®
in an upper corner of the stud cavity. Staple the product to the
side of the stud (creating a 3/4” tab on the product and compressing into the fiberglass (3/4” as well)).
The edge of the product should be flush with the forward corner of the stud.
Proceed “down” stapling to the side of the stud every 2”- 3”.
Repeat procedure on opposite stud.
The Goal: Create a continuous 3/4” air space between the product and the interior panel.
Finish wall interior.
1. Reflectix
®
Insulation
2. 2”x 6” Stud
3. Un-faced Fiberglass
4. Exterior Panel
Tools Required:
Safety Glasses
Staple Gun
Tape Measure
Utility Knife/Scissors
DIY Wall - Exterior 2”x 6”| (Total R-21)
(R-3.9 and a Vapor/Moisture Barrier for the Reflectix
®
)
Reflectix
®
Installation Instructions
1
2
3
4