Pro Residential, Post Frame and Metal Building Applications

Recommended Products:
Staple Tab, Reflective/Bubble/Bubble/Reflective - Roll: ST48100 (48”x 100’)
Below the Purlins
Metal Interior • R-11 Heat Flow Down (and a Radiant Barrier) | R-5.1 Heat Flow Up
Open Interior • R-9.0* Heat Flow Down (and a Radiant Barrier) | R-4.4* Heat Flow Up
Above the Purlins
Metal Interior • R-6.8 Heat Flow Down (and a Radiant Barrier) | R-6.0 Heat Flow Up
Open Interior • R-6.4* Heat Flow Down (and a Radiant Barrier) | R-4.3* Heat Flow Up
Please Note: In addition to the stated R-value, this application also provides a Radiant Barrier.
As a result, a 96% reduction of the radiant energy that ordinarily would be transmitted to the interior of the building is blocked.
Installation Instructions: (There are 2 options)
1. Metal Roof with Product below Purlin (first illustration)
After the trusses are set, run two purlins to make sure the trusses stay true.
Attach the Reflective/Bubble, Staple Tab product to the first truss with at least 5/16” staples.
1. Reflectix
®
Insulation
2. Exterior Roof Panel
3. Purlin
4. Truss
(Note: Applicable for both
diagrams)
Tools Required:
Safety Glasses
Tape Measure
Utility Knife
Staple Gun
Post and Frame Building / Roof / New
Reflectix
®
Installation Instructions
2
1
3
4
1
2
3
4