Pro Residential, Post Frame and Metal Building Applications

Recommended Products:
Staple Tab, Reflective/Bubble/Bubble/Reflective - Roll: ST48100 (48”x 100’)
Metal Interior with a 3/4” Thermal Break • R-8.2* Heat Flow Horizontal
Open Interior with a 3/4” Thermal Break • R-6.0* Heat Flow Horizontal
Metal Interior with a Nominal 3/4” Drape in Product (No Thermal Break) • R-5.9* Heat Flow Horizontal
Open Interior with a Nominal 3/4” Drape in Product (No Thermal Break) • R-4.7* Heat Flow Horizontal
Installation Instructions: (There are 2 options)
1. Installed with 3/4” Thermal Breaks
Install Reflectix
®
Reflective/Bubble/Bubble/Reflective, Staple Tab product vertically, using 1/2” self
tapping screws. This will secure the insulation to the exterior of the C or Z girts.
Tape the seams with a Reflectix
®
Foil Tape (goal is an air-tight, snug seam seal).
Install a 3/4” thermal break and attach corrugated metal exterior finish.
If an interior finish is applied, install the interior panels to the interior face of the girts.
1. Reflectix
®
Insulation
2. Exterior Wall Panel
3. 3/4” Thermal Break
4. Girt
5. Red Metal (Structural
Frame)
Tools Required:
Safety Glasses
Tape Measure
Utility Knife
Screw Gun
Staple Gun
Metal Building / Wall / New
Reflectix
®
Installation Instructions
2
1
3
5
4
4
5
1
2