Quick Start Guide

The tonearm external phono leads must be connected to
a suitable phono stage.
Connect as follows: Red=right channel Black=left channel.
Depending on the type of cartridge you have chosen, you
will require the appropriate moving magnet MM or
moving coil MC stage. If your amplifier does not have an
integrated phono stage you will require an external stage
(sold separately).
Connection to the amplifier
Cartridge alignment protractor
1. Place quick start guide over record spindle.
2. Place needle gently on cross.
3. Move cartridge in headshell until the cartridge and
headshell are parallel with the printed lines.
4. Ensure cartridge is squarely fitted in headshell and then
evenly tighten hardware.
Firstly, ensure the cartridge fixings are orientated correctly
according to the cartridge makers specification. Use the
cartridge alignment protractor to accurately calibrate the
position of the cartridge. Ensure that the tracking force
dial (A) and bias adjustment slider (B) are both set to zero.
Place the balance weight (C) on to the balance weight
shaft. With the stylus guard removed, position the
cartridge above the lead-in groove of an LP. Whilst
supporting the headshell, carefully push the weight further
up the shaft until the stylus is “floating” just 1mm clear of
the record.
The recommended tracking force can now be applied
using the tracking force dial. Always use a force which
corresponds to the upper limit of the cartridge makers
recommended range. Finally, push the bias adjustment
slider to the same number as the tracking force control.
Cartridge mounting and setting up
the RB330 tonearm
Manual speed change
You can change playing speed by simply removing the
glass platter and moving the belt between either the
33 ⅓rpm or 45rpm wheel of the drive pulley.
3