HEALTHY WATER SYSTEM Model No. W15120 Use & Care Guide WARNING: TO PREVENT PERSONAL INJURY OR PROPERTY DAMAGE, READ AND FOLLOW THE INSTRUCTIONS AND WARNINGS IN THIS USE AND CARE GUIDE.
Congratulations on your decision to purchase the AquaVié™ Healthy Water System. We appreciate your confidence and believe that you will find this system easy to use and cost efficient for your household’s water needs. The AquaVié™ Healthy Water System will provide cleaner, good tasting water balanced with calcium and magnesium which are key to protecting your health. Water produced by the AquaVié™ Healthy Water System will quench your thirst with a natural approach.
Table of Contents Important Safeguards ................................................... 1 Specifications.................................................................2 Prepare Your AquaVié™ Healthy Water System Clean the Water Bottle ........................................... 3 Sanitize the Water Bottle ........................................ 3 Prepare the Mineral Dispenser ............................ 3-4 Instructions For Making AquaVié™ Water ...................
IMPORTANT SAFEGUARDS Use electricity safely and wisely. Observe safety precautions when using your AquaVié™ Healthy Water System, including the following: • Read all instructions before using. • Do not run the AquaVié™ unit without water in the boiling chamber. Permanent damage to the boiling chamber could occur. • Make sure the cap is removed on the water bottle and that the water bottle is properly placed on the base of the AquaVié™ unit chassis before starting the AquaVié™ Healthy Water System.
Keep your AquaVié™ Healthy Water System unit clean and replace the mineral dispenser as recommended for ultimate performance. Do not attempt to repair the AquaVié™ unit yourself. If servicing should become necessary, please contact Regal Ware, Inc. at 866-365-5339. SPECIFICATIONS The AquaVié™ system is designed and intended for household use only. The AquaVié™ Healthy Water System conforms to the WQA S-400 standard for the stated performance claims.
Water Bottle Cap Mineral Dispenser Boiling Chamber Cap Baffle Cooling Vents Flat Gasket Dispensing Valve Cord O-Ring Water Bottle Boiling Chamber { { { Securing Nut AquaVié Chassis HOW TO PREPARE YOUR AquaVié™ HEALTHY WATER SYSTEM UNIT Before using your AquaVié™ Healthy Water System unit for the first time, please follow the steps below. CLEAN THE WATER BOTTLE First, make sure the dispensing valve is installed and tightened onto the water bottle.
any carbon dust that formed as a result of shipping. It will also remove any air bubbles present in the carbon. Failure to complete this step may result in water not flowing through the mineral dispenser. If carbon dust appears in your reservoir after your first cycle, discard (water is safe to use for plant watering). Your AquaVié™ Healthy Water System unit is now ready for use.
baffle, flat side down into the spout and secure with the nut. The hole on the flat side of the baffle should be facing down. It is important that you tighten the securing nut, with baffle properly in place, onto the boiling chamber before each use. Failure to properly secure the baffle and nut may result in leakage or early shut off of the AquaVié™ unit. O-Ring Flat Gasket Flat edge of baffle Securing Nut Spout 7.
11. Place a prepared mineral dispenser (see page 3) into the opening at the top of the water bottle. Do not install cap onto water bottle. The bottle must be left uncapped to allow water to enter it from the AquaVié™ unit. 12. Make sure that the dispensing valve is securely tightened onto the water bottle. 13. The base of the AquaVié™ chassis has raised edges to assist in positioning the water bottle properly. Place the water bottle on the base of the chassis.
CLEANING INSTRUCTIONS CAUTION: To prevent personal injury or electric shock, do not immerse the AquaVié™ Healthy Water System unit, its boiling chamber, cord or plug in water or other liquid. Do not use alkaline cleaning agents when cleaning. Use a soft cloth and mild detergent. BOILING CHAMBER Rinse the boiling chamber after every AquaVié™ Healthy Water System cycle is completed. IMPORTANT: Allow the unit to cool completely before removing and rinsing the boiling chamber.
TROUBLESHOOTING GUIDE Problem Start button does not light up. Possible Cause Solution Unit is not plugged in. Plug the unit into a rated voltage outlet. Boiling chamber is not fully inserted. Make sure the boiling chamber is placed properly. See #8 on page 5 Start button lights but fan does not start. The fan’s delayed start system has not yet activated the fan. Wait at least 30 minutes for the fan to start. AquaVié™ unit does not operate. Unit is not plugged in.
TROUBLESHOOTING GUIDE Problem Possible Cause Solution AquaVié™ water The mineral dispenser has an unusual taste. is contaminated. The water bottle is in need of cleaning. The boiling chamber has been over-filled. AquaVié™ unit is leaking. The boiling chamber is not properly installed. The o-ring is damaged or missing from the baffle. The flat gasket between the boiling chamber spout and baffle is missing or damaged. Replace the mineral dispenser. See page 3. Clean the water bottle. See page 3.