Owner`s manual
47
Cosmetic Care & Maintenance
SHOWER SUMP PUMP-TYPICAL
The typical shower sump pump shown above is used to
collect gray water waste from the sinks or the shower itself.
After the liquid reaches a designated height, the sump
pump energizes through a fl oat switch and exits waste to
a manifold then overboard. This system helps to protect
our water supply by not dumping used water overboard.
Periodically check the sump pump grate for debris such as
hair and soap build up. Check to make sure the automatic
fl oat operates freely at all times. Also, clean out the box
with a bleach/water solution as needed to kill bacteria.
You can back fl ush using the bleach/water procedure.
The sump pump box is located near the companionway
stairway.
SIRIUS MARINE WEATHER
If installed the Sirius weather system is a sealed unit.
DO NOT remove the receiver cover. Adjustments
require specialized service procedures and tools only
available to qualifi ed service technicians. There are no
user serviceable parts of adjustments.
Always turn your weather system off before carrying out
routine maintenance.
Peform the following periodically:
1. Examine the cables for signs of damage, such as
chafi ng, cuts, or nicks.
2. Check that the cable connectors are fi rmly attached
and dust caps are fi tted to any connection not in use.