Owner`s manual

40
Chapter 4
POSSIBLE PROBLEMS/SOLUTIONS
1. With generator main control panel ac-
tivated there is no voltage at the AC line
voltage meter. Check AC output breaker
on the generator. It may of tripped due to
an overload.
2. The generator stopped do to overheating. Check the
generator strainer for obstructions such as seaweed, plas-
tic, or shell sh. Be sure to turn off seacock before remov-
ing the strainer basket.
3. The generator will not start from the main ship’s panel
after being serviced. Make sure the generator mounted
switch is in the “run” position.
4. The generator will not crank over to start. Check the
port cranking battery by starting the port engine. If it
starts battery is up. Then check all generator battery con-
nections. Tighten any loose connections.