• CEILING FAN OWNER’S MANUAL • • AMANI • 1/07 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout.
GENERAL INSTALLATION & OPERATION INSTRUCTIONS IMPORTANT SAFEGUARDS: 1. To ensure the success of the installation, be sure to read the instructions and review the diagrams thoroughly before beginning. 2. To avoid possible electric shock, be sure electricity is turned off at the main power box before wiring. All electrical connections must be made in accordance with local codes, ordinances and/or the National Electric Code.
IMPORTANT SAFETY PRECAUTIONS Thank you for choosing a Regency Ceiling Fan. You have chosen the best! Your new ceiling fan has been designed to provide many years of service and enjoyment. Warnings: • Disconnect power by removing fuse or turning off circuit breaker before installing the fan and/or optional lighting. Support directly from building structure.
UNPACKING YOUR FAN 1. Unpack your fan and check the contents. Do not discard the carton. If warranty replacement or repair is ever necessary, the fan should be returned in original packing. Remove all parts and hardware. Do not lay motor housing on its side, or the decorative housing may shift, be bent or damaged. 2. Examine all parts. You should have the following: 16 6 1 B 2 A 8 7 3 C 4 D 9 10 5 11 12 13 15 14 1. 2. 3. 4. 5. 6. 7.
PREPARATION Parts identification on assembled fan Downrod Decorative Wire Supports Collar Cover Uplights (on top of fan motor housing) Blade Motor Housing Blade Arm Switch Housing Accent Cover Plate PREPARATION: Verify you have all parts before beginning the installation. Check foam insert closely for missing parts. Remove motor from packing. To avoid damage to finish, assemble motor on soft padded surface or use the original foam inset in motor box.
INSTALLING THE FAN PRE-MOTOR ASSEMBLY 1. Place the motor assembly on a stable flat surface with the wire lead end facing up. 2. With the motor sitting upright, place the glass support frame onto the support flange of the motor housing assembly. 3. Place the motor housing glass shade into the frame. 4. Remove the 4 screws located on the side of the motor housing. 5. Install the glass retainer bracket using the 4 screws removed. 6. Install uplight bulbs (4). ATTACH DOWNROD: 1.
INSTALLING THE FAN HANG THE FAN 1. Lift ball/downrod/fan into hanging bracket opening. NOTE: The tab opposite hanger bracket opening should fit in slot on ball. 2. Make wire connections, (refer to section titled “Electrical Connections”). 3. Slide canopy up and fasten to hanging bracket with 2 screws provided.
ELECTRICAL CONNECTIONS Four wires are connected to the fan (plus the ground wire). Black - the “hot” power to run fan. White - the “common” power to run fan and light, also referred to as “AC neutral”. Blue - the “hot” power for lower light. Gray - the “hot” power for upper light. Green - ground wire.
BLADE ATTACHMENT BLADE TO BLADE ARM ATTACHMENT 1. Place washer on screw. Insert this assembly through the blade and start the screw into the blade arm. Repeat this procedure without tightening the screw until all 3 screws have been started into the blade arm (Fig. 2). Blade 2. Tighten each screw, starting with center screw. Blade Arm BLADE ARM TO MOTOR ASSEMBLY 1. With the motor assembly hung in place, the blade arms with blades attached can be installed.
SWITCH HOUSING ASSEMBLY 1. With the blade arms attached to the fan, you can attach the switch housing. 2. Loosen two of the three screws located on the mounting hub and remove the third. 3. Feed the light wires through the switch housing. 4. Install the switch housing by aligning the holes in the switch housing to the mounting hub screws. Rotate the switch housing so the third screw hole comes into alignment and attach the third screw. Tighten all three screws once the third screw is installed. 5.
INSTALLATION OF LIGHT KIT (OPTION) 1. With the fan body installed to the ceiling, remove the switch housing cover from the packing. 2. The cover will have three mounting holes in it unlike the access cover which has a threaded pipe. 3. Install the cover to the light kit to be used by threading on the cover to the threaded pipe on the light kit assembly. Feed the wires through while installing the cover to the light kit. Note: Be sure to attach the locking nut to threaded pipe once the cover is attached.
COMPLETING THE INSTALLATION 1. Install 4 candelabra base bulbs (E12, 25 watt maximum) into sockets on top of fan body. 2. Screw decorative wire support into metal frame of fan body. 3. Hook decorative wire support into corresponding loop on bracket. 4. Slide bracket up downrod as far as it can go and tighten security screw.
REMOTE CONTROL GENERAL INFORMATION Multiple code choices are included with your fan’s remote control in case: • you have more than one remote control fan and want them to respond only to their own remote control • you have other radio controlled devices in your home that may interfere with the fan remote control (i.e. garage door opener) • you experience radio interference on a chosen frequency (code setting) SET-UP AND OPERATING INSTRUCTIONS Setting the code: This unit has 16 different code combinations.
OPERATION OPERATING BUTTONS ON THE TRANSMITTER HI – fan high speed MED – fan medium speed LOW – fan low speed FAN/OFF – fan speed off LIGHT – light brightness and off function for uplight FOR/REV – forward and reverse • The light functions are controlled by pressing the light button. Tap button quickly to turn light off or on. Push the button once and release to turn the light on to full brightness. Hold the button down to increase or decrease light brightness.
TROUBLESHOOTING - IN CASE OF DIFFICULTY IMPORTANT: To prevent damage or cause injury, be sure that fan is switched to off and blades have stopped moving completely before attempting to change direction of rotation. 1. If fan will not start: Check main and branch circuit breakers and/or fuses. Check line wire connections to fan and switch housing wiring. Make sure forward/reverse switch is set to one or the other position, not stuck in between. 2.
THANK YOU FOR PURCHASING A REGENCY CEILING FAN. Write to us at: Regency Ceiling Fans P.O. Box 730 Fenton, MO 63026 For additional troubleshooting tips, visit us on the Web at: www.regencyfan.