Regency HZO42 Outdoor Gas Fireplace Owners & Installation Manual MODELS: HZO42-NG HZO42-ULPG LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AS4565 / NZS 4558 and have been certified by the IAMPO Oceana for installation and operation as described in these Installation and Operating Instructions. Your unit should be serviced annually by an authorised service person. www.regency-fire.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The HZO42 Outdoor fireplace has been designed to provide you with all the warmth and charm of a fire at the flick of a switch. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency® Fireplace.
TABLE OF CONTENTS DATA BADGE Copy of Data Badge ......................................................4 DIMENSIONS Unit Dimensions ............................................................5 INSTALLATION Important Message ......................................................6 Before You Start ............................................................6 General Safety Information............................................6 Installation Checklist .....................................................
DATA BADGE This is a copy of the data badge that accompanies each HZO42 Outdoor Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. Regency Gas Fireplace Model Distributed by: Gas Type NG ULPG Model HZO42-NG HZO42-ULPG Gas Consumption 47mj. 47mj. Manifold Pressure 0.88 kPa 2.49 kPa Injector Size 1x#29 1x#47 3.45mm 1.
DIMENSIONS UNIT DIMENSIONS 37 - 13/16” (960mm) 41 - 11/16” (1059mm) 43 - 11/16” (1110mm) 16 -1/2” (491mm) 43-1/4” (1099mm) 15 - 1/4” (387mm) 4-7/16” (113mm) 25-3/16” (640mm) 32 - 7/16” (824mm) 12 (102mm) 20-3/4” (527mm) 5/8” (16mm) 10” (254mm) 13 - 7/16” (341mm) 5 Regency HZO42 (Aus) Gas Fireplace
INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The HZO42 Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes.
INSTALLATION LOCATING YOUR GAS FIREPLACE INSTALLATION CHECKLIST Installation in accordance with AS/NZS5601. 1) This appliance must only be used in a well ventilated area. 1) Locate appliance: 2) When selecting a location for your fireplace, ensure that the clearances are met.
INSTALLATION IMPORTANT INFORMATION FOR OUTDOOR FIREPLACE INSTALLATIONS • • Never insulate around the body of the unit Excessive heat retention in the firebox will lead to component failure and fireplace malfunction Excessive heat retention will also increase the risk of fire inside the chase Heat retention can cause “Oil-canning” and damage the fireplace due to overheating Do not build up a wall of any type in front or to the sides of the appliance, higher than the firebox opening.
INSTALLATION MINIMUM CLEARANCES TO COMBUSTIBLES The clearances listed below are Minimum distances unless otherwise stated: A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace be installed only in accordance with these instructions. WARNING Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to.
INSTALLATION FRAMING DIMENSIONS Framing Dimensions Description A B C D E F G H I J Header Height Side Stud Width Minimum framing depth Minimum Height to Combustibles Minimum framing width Corner Wall Depth Corner Facing Wall Width Gas Connection Opening Height Gas Connection Height Gas Connection Inset 32-11/16” (30mm) 42 - 3/16" (1072mm) 20" (508mm) 52 - 1/2" (1334mm) 60" (1524mm) 40 - 7/16" (1027mm) 54 - 3/16" (1376mm) 2" (51mm) 3-7/8 " (98mm) 3/4" (73mm) K Gas Connection Opening Width 3-7/8 " (98m
INSTALLATION MANTEL CLEARANCES 26”(660mm) 6 4 2 0 10 8 1" (25mm) Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. 14 12” (305mm) Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right.
INSTALLATION FINISHING IMPORTANT FINISHING DETAIL NOTE: Before placing unit into final position - it is important to know the total thickness / height of finished hearth. The base of the fireplace should be level or higher than the finished hearth height.
INSTALLATION HZO42-NG SYSTEM DATA Max. Supply Pressure 14" WC (3.49 kpa) Min. Supply Pressure 5" WC (1.25 kpa) Manifold Pressure 3.5" WC (0.88 kpa) Orifice Size #29 DMS Maximum Input 47 mj PILOT ADJUSTMENT Periodically check the pilot flames. Correct flame pattern has two strong blue flames: 1 flowing around the flame sensor and 1 flowing across the burner (it does not have to be touching the burner). Burner Flame Sensor HZO42-ULPG SYSTEM DATA Max. Supply Pressure 14" WC (3.49 kpa) Min.
INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION NAILING STRIPS The 6 Standoffs must be correctly positioned and attached before unit is slid into position. The nailing strips come attached to the unit. There is 1 plate on each side and 1 on the top that can be folded out as required. Secure the top and side nailing strips to the framing. STANDOFF ASSEMBLY The standoffs are shipped in a flat position and must be folded into shape and attached. 1) Remove the standoffs from the fireplace.
INSTALLATION WALL SWITCH INSTALLATION (INCLUDED WITH UNIT) 1) The unit comes with 10' of wire located on the left side of the unit. 2) Install supplied electrical box in desired location. 3) Route low voltage wire through electrical box. 4) Connect 2 wires to switch (use supplied dielectric grease on connections) 5) Install weather resistance cover plate to switch using 2 inner holes with screws provided.
INSTALLATION WIRING DIAGRAM This heater does not require a 240V A.C. supply for operation. (Do not cut the ground terminal off under any circumstances.) NOTE: 4 AA batteries must be installed in the battery pack to operate the burner switch. Proflame 880 SureFire™ Switch 0.886.001 880 Proflame Valve Standard Main On/Off Switch Standard Wall Switch or Optional Wall Switch Remove the protective coating from the following components before proceeding.
INSTALLATION INNER PANEL INSTALLATION Before installation, panels must be handled and cleaned as per instructions noted below: Stainless Steel Panels • Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. • To protect the finish during installation and handling - cotton gloves MUST be worn at all times while handling the panels (even when removing protective coating).
INSTALLATION GLASS CRYSTAL / GARDEN STONE INSTALLATION Evenly spread the Glass Crystals or optional Ceramic Spa Stones over the burner. Ensure the crystals (or stones) do not overlap too much as this will effect the flame pattern. IMPORTANT NOTE: Only the supplied approved Glass Crystals and Ceramic Spa are to be used with these fireplaces.
INSTALLATION PEBBLE INSTALLATION Unit Glass Crystals Pebbles HZ54E / HZ54EPV 6 lbs 2 packages (6 x bags pebbles) HZ42 / HZ42E/HZ40E 5 lbs 2 packages (6 x bags pebbles) HZ42ST / HZ42STE / HZ42STEPV 5 lbs 2 package (6 x bags pebbles) HZ30E 2 lbs 1 package (3 x bags pebbles) HZI390E/ HZI390EB 3 lbs 1 package (3 x bags pebbles) HZI234E 2 lbs 1 package (3 x bags pebbles) HZO42 / HZO42 (AUS) 3 lbs 1 package (3 x bags pebbles) P33S / P33SE 3 lbs 1 package (3 x bags pebbles) U32S / U32SE
INSTALLATION VOLCANIC STONE INSTALLATION Evenly spread the glass crystals and volcanic stones over the burner. Ensure the stones do not overlap too much as this will effect the flame pattern. IMPORTANT NOTE: Only the supplied approved Volcanic Stones are to be used with these fireplaces. Use of any other type of stones can alter the unit's performance, any damage caused by the use of any unapproved glass or stones will not be covered under warranty.
INSTALLATION OPTIONAL LOG SET INSTALLATION Installation of Reflective Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Install 3lbs of glass crystal on the burner (follow glass crystal instruction sheet) before installing logs.
INSTALLATION 4) Install log D on the burner as shown below. Orient log D across log E in the same way and in a similar position as depicted in Diagram 5- log D will rest up against the back panel. D E Diagram 5 5) Install log F on the right side of the burner as shown below. Orient log F in the same way and in a similar position as depicted in Diagram 6.
INSTALLATION HEAT DEFLECTOR INSTALLATION 1) Install the heat deflector to the top inside of the firebox with 4 screws as shown below.
INSTALLATION FACEPLATE INSTALLATION Remove the protective coating from the faceplate before installation - see handling instructions in panel install section. 1) 3) For installations where thicker finishing material is used - the optional trim piece may be installed to fill the gap. Install the trim in front of the bottom access panel as shown below. To install the faceplate - line up the tabs on the faceplate with the 'C' shaped openings on the left and right sides of the unit.
INSTALLATION GLASS WIND SHIELD INSTALLATION 1) To install the glass wind shield - slot it into the space between the burner tray cover and the bottom access panel. Burner Tray Cover Glass Wind Shield Bottom Access panel WEATHER COVER INSTALLATION / REMOVAL 1) The unit should be covered when not in use for extended periods of time. The soft fabric cover is made of weather resistant material - to protect the unit from the elements.
INSTALLATION ASSEMBLY INSTRUCTIONS FOR A STEEL STUD FRAMING KIT FOR HZO42 Follow these instructions to construct a steel stud frame for the Outdoor fireplace; Overall dimensions = 70-15/16" (1801mm) W x 20" (508mm) D x 47-5/16" (1201mm) H. **Non-combustible finishing board not supplied with kit. Board may be purchased at your local hardware/building supply store.
INSTALLATION 1) Place top/bottom (A) on the ground - flat side down. Bend the tabs up to a 90° angle. 3) Line up the screw holes of (A) with (B). Secure each (B) with 2 wafer screws (one on each side) as shown below. (A) (B) (A) Bend tabs inward to 90°angle. 4) With all 4 - (B) pieces secured to the bottom with 2 screws (1 on each side) (A) can be placed into position, as shown below. Ensure all tabs on the (A) are bent to 90° and oriented to each (B) as shown in step 2.
INSTALLATION 6) Manoeuvre remaining (B) pieces and position in each corner of the frame - flat side facing out - see 2 diagrams below. 9) Position remaining 2 - (C) pieces offset from center rib as shown below. (C) 10) Position (D) on top of (C) pieces - line up screw holes and secure (D) to (C) with 12 wafer screws. 7) LIne up screw holes on top / bottom (A) with each (B)- secure with 3 wafer screws each on top and bottom - 6 screws in total for each outer (B) (3 top- 3 bottom).
INSTALLATION 12) LIne up screw holes on (E) (header) and (B) (inner vertical support). Secure with 2 wafer screws on each side (4 total) as shown below. This will now be the front of the frame. 14) Line screw holes on 1 (F) (corner brace) with (B) + (A) and secure with 4 wafer screws. as shown below. (A) (B) (F) (E) 15) Repeat step 14 for opposite corner as shown below. 13) On the back side of the frame. Install both (F) pieces (corner brace) on opposite corners.
INSTALLATION REMOTE PROPANE / ULPG GAS ENCLOSURES INSTALLATION GUIDELINES If the unit is permanently connected to a gas piping system from a remote supply tank, installation must be in accordance with local codes or, in absence of local codes, with the AS/NZS5601 'gas installation code'.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. FIRST FIRE The first fire in your fireplace is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it .
OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS The lighting plate is located on the underside of the front access panel in the unit. FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1.
MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve and unplug the batteries before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged. 2) Clean appliance with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fireplace glass cleaner.
MAINTENANCE VALVE ASSEMBLY REPLACEMENT 1) Turn the unit off and allow it to cool down to room temperature. 9) Remove the front access panel by lifting up and out. 2) Turn off the gas supply to the unit. 3) Remove trim. 4) Remove the faceplate by lifting it up and off the unit. 10) Remove the burner tray by lifting up and out. 5) Remove the glass wind shield by lifting it up and out- place on a soft surface. 11) Remove left and right screws from the burner legs.
MAINTENANCE 12) Slide the burner to the right and lift up and out of the firebox. BATTERY REPLACEMENT 1) Remove the 2 screws securing the battery compartment. 13) Remove the 5 screws securing the Digital Fireplace Burner Control to the firebox. 2) Lift the battery compartment upwards. 14) Remove the DFBC from the unit - see page 37. 3) Install 4 - AA batteries and reverse steps. 15) Remove 6 screws an lift out valve tray. 16) Replace with new valve tray and reverse steps.
MAINTENANCE DIGITAL FIREPLACE BURNER CONTROL REMOVAL 1) To access to the Digital firebox burner control box - follow steps 1-11 from the Valve assembly replacement instructions on pages 35,36. 5) Disconnect the yellow ground wire with green diagonal stripe for pilot (CN2). See Diagram 4 below. 2) Disconnect the Black Pilot sensor wire with Red Spade connector from the 'ON' on DFBC (Digital fireplace burner control) box. See Diagram 1 below.
PARTS LIST Part # Description 1) 326-554 Faceplate Assembly 2) 326-072 3) 940-368/P 4) 326-525 Heat Deflector Wind Shield Burner Assembly NG/LPG/ULPG 5) 904-777 904-434 Orifice # 29 (NG) Orifice # 47 (LPG/ULPG) 6) 326-574/P 326-576/P Valve Assembly NG Valve Assembly Propane/ULPG 7) 326-007/P 8) 326-008 MAIN ASSEMBLY 326-028 326-036 326-036 Pilot Hood Top nailing strip Side nailing strip 948-223 326-073 911-976 Logo Plate Weather Cover Digital Fireplace Burner Control 918-976 Manual Front ac
PARTS LIST BURNER ASSEMBLY Part # 9) Description 326-525 326-525 Part # Description Burner Assembly NG Burner Assembly ULPG 904-660 904-431 Orifice #29 NG Orifice #47 LPG/ULPG 10) 911-024 911-025 Valve NG SIT 880 Valve LPG/ULPG SIT 880 326-930 Log Set 11) 326-008 Burner Tray Cover 12) 911-006 911-007 911-037 911-038 910-432 Pilot Assembly - NG Pilot Assembly - LPG/ULPG Flame Sensor Igniter Pilot Tube 9 12 10 11 38 Regency HZO42 (Aus) Gas Fireplace
PARTS LIST ACCESSORIES Part # Description 326-021 326-022 326-023 Reflective Stainless Steel Inner Panels Rear panel staniless Left Panel Stainless Right Panel Stainless 13) 14) 940-368/P Glass windshield 15) 326-554 Faceplate Brushed Stainless 946-676 946-695 Copper Glass Crystals Garden Stones 13 15 14 39 Regency HZO42 (Aus) Gas Fireplace
NOTES 40 Regency HZO42 (Aus) Gas Fireplace
NOTES 41 Regency HZO42 (Aus) Gas Fireplace
NOTES 42 Regency HZO42 (Aus) Gas Fireplace
WARRANTY Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited warranty to the original purchaser of a Regency® Product. This warranty is not transferable.
Register your Regency® warranty online www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.