www.regency-fire.com C33 Classic Freestanding Gas Stove Owners & Installation Manual Classic C33 model shown above features optional gold plated door and gold legs. MODELS: C33-NG3 Natural Gas C33-LP3 Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed ex- What to do if you smell gas: actly, a fire or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Stove by Fireplace Products International Ltd. The Regency® Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the flick of a switch. The models C33-NG3 and C33-LP3 have been approved by Warnock Hersey for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Serial No. Decal ............................................................4 Operating Instructions .................................................16 Lighting Procedure ......................................................16 Shutdown Procedure ...................................................16 Maintenance Instructions ............................................16 Copy of the Lighting Plate instructions .......................
SAFETY LABEL This is a copy of the label that accompanies each CLASSIC Freestanding Gas Stove - Natural Gas and Propane. We have printed a copy of the contents here for your review. The safety label is located on the back panel. NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.
INSTALLATION BEFORE YOU START IMPORTANT MESSAGE Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following: The CLASSIC Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation.
INSTALLATION This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label) after burning appliance for 15 minutes. 2) If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize. 3) Check for proper draft. CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
INSTALLATION Wiring 16) Pull power wire back and put strain relief grommet in place as per diagram 4. 11) Remove the dummy plug from the right side of the bottom shield or pedestal and install the supplied fan switch. 12) Attach hot wire from power cord to the thermodisc. 13) Slide the thermodisc under the bracket. 17) Reverse steps 3-1 to complete installation. Note: The #8 ground lug is a dedicated ground for mobile home use only. Only C34 unit is approved for mobile homes.
INSTALLATION LEG AND BOTTOM SHIELD ASSEMBLY OPTIONAL OUTSIDE AIR These instructions apply to the steel leg, painted cast leg and the gold plated cast leg. It will be easier to attach the legs to the stove if it is tipped on its back (preferably on a soft surface to prevent scratching). If needed, outside air for combustion can be brought in either through the bottom of the pedestal or through the rear plate of the pedestal. 1) Remove the 4 bolts in the underside of the base and discard.
INSTALLATION Installing into Existing Woodstove Flue System GAS PIPE PRESSURE TESTING SYSTEM DATA (For 0 to 2,000 feet altitude) 1) Clean existing chimney system. 2) Install stove pipe adapter 3) Install any reducers that may be needed to fit 6" flue pipe adapter. 4) Run 4" flex liner into existing chimney. 5) Slip liner through 6" flue pipe and hook up to flue collar with screws. Note: For ease of installation, use a slip section when installing with a vertical flue pipe.
INSTALLATION INSTALLATION OF THE DC SPARKER VALVE DESCRIPTION 4) Loop the wires through the heat shield. (APPLIES ONLY TO LP UNITS) 1) Attach the ground wire to the grounding stub. 5) Install the plastic bushing over the outside of the hole to protect the wires from the sharp edges.
INSTALLATION TEST FOR FLUE SPILLAGE LOG SET INSTALLATION This heater must be properly connected to a venting system. WARNING: Dangerous operating conditions may occur if these logs are not positioned in their approved locations. Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot and burner operation.
INSTALLATION SAFETY LATCH REMOTE CONTROL INSTALLATION WALL THERMOSTAT INSTALLATION Use the Regency® Remote Control Kit approved for this unit. Use of other systems may void your warranty. Regency® offers an optional programmable thermostat but any 250-750 millivolt rated nonanticipator type thermostat that is CSA, ULC or UL approved may be used. Secure door in the closed position using the door securing bracket and the screw provided.
INSTALLATION WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation. Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to instructions in this manual. NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS LIGHTING PROCEDURE MAINTENANCE INSTRUCTIONS 1) The FIRST FIRE in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on. When first operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufacturing.
OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261) WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
MAINTENANCE CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE. CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. NEVEROPERATETHEAPPLIANCE WITHOUT THE GLASS PROPERLY SECURED IN PLACE. GENERAL VENT MAINTENANCE Conduct an inspection of the venting system at least annually. Recommended areas to inspect are: 1) Check areas of the Venting System which are exposed to the elements for corrosion.
MAINTENANCE LOG REPLACEMENT The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, use only Regency® replacement logs. The position of these logs must be as shown in the diagram under Log Installation.
MAINTENANCE REMOVING VALVE ASSEMBLY 1) Shut off gas supply. 2) If optional fan is installed, disconnect power source to stove. 3) Remove access panel. a) Front panel on pedestal model. See diagram 1. b) Panel from bottom of leg shield. See diagram 2. Note: Access panel only has to be loosened to be taken out. 8) If optional fan is installed, remove thermodisc to bracket by removing three (3) phillips head M5 screws. 9) Remove front cover with Piezo Igniter by removing two (2) sheet metal screws.
PARTS LIST MAIN ASSEMBLY Part # Description 850-141 850-142 850-143 850-144 Small Door - Black Small Door - Gold Small Door - Nickel Accent Small Door - Gold Accent 850-151 850-152 850-153 850-154 Large Door - Black Large Door - Gold Large Door - Nickel Accent Large Door - Gold Accent 3) 4) 5) 6) 7) 9) 10) 12) 13) 14) 15) 16) 17) 19) 846-302 936-243 846-920 * 948-170/P 846-973 910-250 846-570 846-918 * * * 471-031 948-101 Small Glass Glass Gasket (7/8") Glass Retainer Clips (8/set) Screw 1/4 - 20 x
PARTS LIST BURNER & LOGS Part # Description 910-190 * 908-672 Piezo Ignitor & Nut Control Panel Control Panel Decal 68) 69) 70) 462-560/P 462-561/P 910-478 910-034 910-035 904-604 904-390 948-279 948-294 948-232 Valve Assembly - S.I.T. - NG Valve Assembly - S.I.T. - LP Valve S.I.T. - NG/LPG Pilot Assembly-3 flame-S.I.T. -NG Pilot Assembly-3 flame-S.I.T.
PARTS LIST BASE OPTIONS 100) 102) 103) 108) 109) 110) 121) 140) Part # Description 490-921 948-216 948-223 904-257 * 910-246 910-272 * * Complete Floor Shield Regency® Logo (Gold) Regency® Logo (Silver) Magnetic Catch (Large) 11" Pedestal Hinge Burner ON/OFF Switch (2-way) LT.
NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _____________________________________
NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ______________________________________
NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ______________________________________
WARRANTY Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product. This warranty is not transferable.
Regency® fireplace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency® Product. See the inside back cover for details. Register your Regency® online at http://www.regency-fire.