REP OP/CL#1:NO
Select this option if you want the system to send Normal and Exceptional Open and Close
Reports to Phone #1.
REP DOOR#1:YES
Select this option if you want door access information to be reported to Phone #1.
REP TEST #1:YES
Select this option if you want test signals to be reported to Phone #1. (Event memory reports if
selected will also report to TEST accounts.)
MUST REP#1:YES
If this option is selected, the system MUST report to Phone #1. If this option is not selected,
Phone #1 will only be used as a backup if an event cannot be reported to another number.
NOTE The MUST REPORT numbers must be the lower numbers (before the backups). Your choices
are: 1, 1&2, 1&2&3, 1&2&3&4.
FORMAT#1:SIA8
Select the digit shown in the table below next to the format that Account #1 will use. The com-
patible Regency receivers and/or line cards are shown in parentheses.
NOTE 1. SIA8 and SIA20 are the only formats that can report event memory and ID numbers higher
than 99. Also Door Restore and Access Denied Reports are only supported with SIA formats.
2. Do not select SIA20 unless the receiver has a 9004I card. The 9004 card can only accept
SIA8.
ATTEMPTS #1:1
Enter the number of attempts (1-15) that the communicator will try to report to this account
number before switching to the next number (typically one attempt).
LISTEN IN#1:0
Enter, in seconds, the length of time the central station can listen in to the site on this account
number (20 - 255 seconds; 0 if not used).
Select this option to allow the central station to listen in to the site on this account number.
NOTE The Listen-in feature is not recognized by UL.
Table 10: Reporting Formats
Selection Format and Compatible Receiver
0 SIA8 (9004, 9004l)
1 FSK1 (8520, 9002, 9032)
2 FSK2 (9002, 9032)
3 BFSK 1400 HZ (9002, 9032)
4 BFSK 2300 Hz (9002, 9032)
5 SIA20 (9004I)
6 SK4+2 (9002, 9032)