User guide

27
Regency Bellavista™ B36X Gas Fireplace
VENTING ARRANGEMENTS
ALLOWABLE VERTICAL TERMINATIONS
(MUST USE VENT REDUCER # 946-606 & RIGID PIPE ADAPTOR #770-994)
4" X 6 - 5/8" PIPE VENTING ARRANGEMENTS
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90
o
elbows, with
Rigid Pipe Venting Systems for Propane and Natural Gas. Two 45
o
elbows equal to one 90
o
elbow. Maximum of four 45
o
elbows allowed.
Note: The Regency Direct Flex Kits (946-515 and 946-516) cannot be used in conjunction with the vent reducer and rigid pipe adaptor.
Only rigid pipe may be used when 4" x 6-5/8" is ever used.
Vent must be supported at offsets.
Firestops are required at each oor level and whenever passing through a wall.
Maintain clearances to combustibles as listed in the "Clearances" section.
Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting
to 2" opening to 1" opening.
Note: Must use optional ue adapter when using Rigid Pipe (Part # 770-994).
INSTALLATION
Maximum: 35.5 ft. (10. m)8
Minimum
8’ (2.4m)
Min. 49”
(1.2m)
Max. 10’ (3m)(centerline to centerline)
Maximum: 19 ft. (5.8m)
0
2
4
6
40
8
10
12
14
16
18
20
22
24
26
28
30
Vertical Height (Feet)
32
34
36
38
6
8
Horizontal (Feet)
2
0
4 10
12
16 18
14
Restrictor 1” Open
Restrictor 2” Open
Maximum 12’ Centerline to Centerline