Regency Bellavista™ B36XT Gas Fireplace Gas Fireplace Owners & Installation Manual MODEL: B36XT Medium DV Gas Fireplace www.regency-fire.com WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: Do not try to light any appliance a fire or explosion may result causing property damage, Do not touch any electrical switch: personal injury or loss of life. do not use any phone in your FOR YOUR SAFETY building.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The Bellavista™ B36XT has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The Bellavista™ B36XT has been approved by Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency® product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88a-2007 / CSA 2.33a-2007 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91.
TABLE OF CONTENTS SAFETY LABEL Copy of Safety Decal .....................................................5 REQUIREMENTS MA Code - CO Detector.................................................6 DIMENSIONS Unit Dimensions ............................................................7 INSTALLATION Important Message ......................................................8 Before You Start ............................................................8 General Safety Information....................................
SAFETY LABEL This is a copy of the label that accompanies each Bellavista™ B36XT Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. COPY OF SAFETY DECAL Duplicate S/N - 353 DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE Listed: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION Serial No.
REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.
DIMENSIONS UNIT DIMENSIONS 33” (838mm) 35-1/4” (895mm) 30-3/8” (762mm) CL 41-5/16” (1049mm) 11-7/16” (291mm) 21”(533mm) 40-5/16” (1024mm) 1”(25.
INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The B36XT Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes.
INSTALLATION INSTALLATION CHECKLIST 1) Locate appliance a) Room location (Refer to "Locating Your Gas fireplace" section) b) Clearances to Combustibles (Refer to "Clearances" section) c) Mantle Clearances (Refer to "Combustible Mantel Clearances" section) d) Framing & Finishing Requirements (Refer to "Framing & Finishing" section) e) Venting Requirements (Refer to "Venting" section) This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label 31,000 Btu/h, after burning a
INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. WARNING Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to.
INSTALLATION MANTEL CLEARANCES Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
INSTALLATION MANTEL LEG CLEARANCES 3" Mantel leg Mantel leg 1-1/2" 12” Side Wall (Measured from side of Fireplace Opening) 3.5” 6.5" Allowable mantel leg projection. NON- COMBUSTIBLE REQUIREMENTS: 42" (1067mm) Non-combustible 42-1/4" Non-combustible (1073mm) Non-combustible Material Min. 7" (178mm) Non-combustible Header (steel stud) on edge 35-1/4" (895mm) 36" (914mm) Min. 3” (76mm) 40 - 5/8" (1032mm) Framing Min. 3” (76mm) See framing dimensions on next page.
INSTALLATION FRAMING Framing Dimensions Description B36XT M Framing Width 40-5/8"(1032mm) N Framing Height O (Rear Vent) Framing Depth - Rear Vent 42" (1067mm) 20-3/4" (527mm) O (Top Vent) Framing Depth - Top Vent 20-1/2" (521) P (Top Vent) Corner Facing Wall Width 48 - 5/8" (1235mm) P (Rear Vent) Corner Facing Wall Width 53" (1346mm) AstroCapXL 61-1/2" (1562mm) - other approved caps Q (Top Vent) Corner Facing Wall Width 68-3/4" (1746mm) Q (Rear Vent) Corner Facing Wall Width 75" (1
INSTALLATION FINISHING IMPORTANT FINISHING DETAIL NOTE: Important: Before placing unit into final position - it is important to know the total thickness / height of finished hearth (tile, carpet, etc.) The base of the fireplace should be level or higher than the finished hearth height. Finishing materials such as tile, river rock, etc, must not protrude beyond the front facing flanges the sides and top of the firebox opening.
INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION BEFORE YOU START The Top Facing Support, the Side Nailing Strips, the 2 Top Standoffs and the Flue Collar must be correctly positioned and attached before the fireplace is moved into position. TOP STANDOFF ASSEMBLY The top standoffs are shipped in a flat position and must be folded into shape and attached. 1) Remove the standoffs from the fireplace top. 2) Take each standoff and bend into the correct shape.
INSTALLATION CONVERSION TO TOP VENT Note: This conversion must be done prior to the unit being placed in position. The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented.
INSTALLATION 5) From the outside rear of the firebox, remove the intake collar assembly. Remove the 4 - 1/4" x 1/2" screws. See Diagram 5. Diagram 9 Exhaust Assembly Intake Collar Assembly 9) From the outside top of the firebox, install the intake collar assembly. Secure with 4 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over tighten. All 4 screws must be used.
INSTALLATION VENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATION NOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INSTALLED PRIOR TO OPTIONAL PANEL INSTALLATION. 1) Determine the venting configuration. 2) Remove top heat deflector and baffle plate (reverse of steps 5 & 6). 3) Go to venting arrangements section (in the manual) to determine if a vent restrictor setting is required. Note: The vent restrictor does not apply to rear vent applications.
INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance Requirements Canada1 USA2 A Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) B Clearance to window or door that may be opened 12"(30cm) 9" (23cm) C Clearance to permanently closed window * * D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) from the center line of the terminal (check with the local code) 24"(60cm) 24"(60cm) E C
INSTALLATION 4" X 6-5/8" RIGID PIPE CROSS REFERENCE CHART ONLY Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI.
INSTALLATION Description Simpson Selkirk Direct Vent Pro® Direct Temp™ American Metal Products® Metal-Fab™ Security ICC Excel Sure Seal Secure- Vent® Direct Amerivent Direct Attic Insulation Shield 12” 46DVA-IS N/A@ FPI N/A 4DAIS12 N/A SV4RSA N/A Attic Insulation Shield - Cold Climates 36” N/A N/A 4DAIS12 N/A N/A TM-4AS Basic Horizontal Termination Kit (A) Disc.
INSTALLATION 5" X 8" RIGID PIPE CROSS REFERENCE CHART ONLY Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI.
INSTALLATION Description Attic Insulation Shield 12” Simpson Selkirk Metal-Fab™ ICC Excel Direct Vent Pro® Direct Temp™ Sure Seal Direct 58DVA-IS N/A from FPI N/A N/A N/A Basic Horizontal Termination Kit (A) N/A 5DT-HKA N/A N/A Horizontal Termination Kit (B) 58DVA-KHA 5DT-HKB N/A N/A Vertical Termination Kit 58DVA-VHA 5DT-VKC N/A N/A High Wind Vertical Cap 58DVA-VCH N/A N/A TM-5VT High Wind Horizontal Cap N/A N/A N/A TM-5DHT Horizontal Square Termination Cap N/A 5DT-
INSTALLATION VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS FLEX VENT OR RIGID PIPE 5" X 8" The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of 3ft (0.9m).
INSTALLATION HORIZONTAL TERMINATIONS FLEX VENT 5" X 8" These venting systems, in combination with the B36XT Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations" section.
INSTALLATION HORIZONTAL TERMINATIONS RIGID PIPE 5" X 8" Vinyl Siding Standoff (Optional) Vinyl Siding Standoff (Optional) Horizontal Termination Cap Horizontal Termination Cap Wall Thimble Wall Thimble Pipe Length Pipe Length Rigid Pipe Adaptor o 90 Elbow Rigid Pipe Adaptor B A Horizontal Termination 26 A Top Vent - No Vertical Rise • When venting with a 90° elbow directly off the unit, must use 5" X 8" AstroCapXL™ Flex vent or approved Rigid Vent System • Max. 3 ft.
INSTALLATION HORIZONTAL TERMINATIONS ASTROCAP XL & RIGID REAR VENT KIT FOR CORNER INSTALLATIONS RIGID PIPE 5" X 8" Designed for a minimum vent configuration when using a rear vent application with a horizontal termination in a corner installation.
INSTALLATION VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS RIGID PIPE 4" X 6-5/8" (MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o two 45o elbows equal one 90o elbow).
INSTALLATION HORIZONTAL OR VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" (MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR) The minimum components required for a basic horizontal termination using 4" x 6-5/8" are: 1 1 1 1 1 1 Rigid Pipe Adaptor (770-994) Reducer (946-606) 90o Elbow Wall Thimble Length of pipe to suit wall thickness Horizontal Termination Cap Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap.
INSTALLATION HORIZONTAL TERMINATIONS TWO (2) 90O ELBOWS (RIGID PIPE 4" X 6 - 5/8") H1 V H One 90o elbow = Two 45o elbows. Option A) B) C) D) E) F) G) V 0' Min. 1' Min. 2' Min. 3' Min. 4' Min. 5' Min. 6' Min. H + H1 2' Max. 3' Max. 4' Max. 5' Max. 6' Max. 7' Max. 8' Max With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal. Please note minimum 1 foot between 90o elbows is required.
INSTALLATION VENTING ARRANGEMENTS FOR VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" (MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR) The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbows, with Rigid Pipe Venting Systems for Propane and Natural Gas. Two 45o elbows equal to one 90o elbow. Maximum of four 45o elbows allowed. Horizontal (Feet) 0 2 4 6 10 8 12 40 38 36 Maximum: 35.5 ft. (10.
INSTALLATION VERTICAL TERMINATIONS THREE (3) 90O ELBOWS (RIGID PIPE 4" X 6 - 5/8") V1 One 90o elbow = Two 45o elbows. Option A) B) C) D) E) F) G) H) V 0' Min. 1' Min. 2' Min. 3' Min. 4' Min. 5' Min. 6' Min. 7' Min. H + H1 2' Max. 2' Max. 3' Max. 4' Max. 5' Max. 6' Max. 7' Max. 8' Max. V + V1 2' Min. 3' Min. 4' Min. 6' Min. 7' Min. 8' Min. 9' Min. 10' Min. H1 H V With these options, max. total pipe length is 30 feet with min. of 10 feet total vertical and max. 8 feet total horizontal.
INSTALLATION VENTING ARRANGEMENTS WITH CO-LINEAR FLEX SYSTEM Masonry chimneys may take various contours which the flexible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending. THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. The Air Intake pipe must be attached to the inlet air collar of the termination cap.
INSTALLATION VERTICAL TERMINATIONS CO-LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL & MANUFACTURED HOMES The shaded area in the diagrams show the allowable vertical terminations.
INSTALLATION UNIT INSTALLATION WITH HORIZONTAL TERMINATION 5) Assemble the desired combination of pipe and elbows to the appliance adaptor and twist-lock for a solid connection. 4" X 6-5/8" OR 5" X 8" VENTING (Rigid Vent Systems) Note: For best results and optimum performance with each approved venting system, it is highly recommended to apply “Mill-Pac” sealant (supplied) to every inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty.
INSTALLATION Minimum Vent Clearances to Combustibles * Clearances noted below must be maintained; except when passing through a wall, ceiling or at the termination where the use of a firestop or wall thimble reduces clearance to 1-1/2" (38mm).
INSTALLATION UNIT INSTALLATION WITH VERTICAL TERMINATION 4) Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed. 4" X 6-5/8" VENTING (Rigid Vent Systems) (MUST USE REDUCER #946-606 AND RIGID PIPE ADAPTOR #770-994) 1) Maintain the 1-1/2" clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces.
INSTALLATION PILOT ADJUSTMENT Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile, 1 around the thermocouple and 1 flowing across the burner (it does not have to be touching the burner). Note: If you have an incorrect flame pattern, contact your FPI dealer for further instructions. B36XT -NG System Data Conversion Kit # 576-969 For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: #35 Max. Input Rating Min.
INSTALLATION CONVERSION KIT# 576-969 FROM NG TO LP for B36XT using SIT 820 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Each Kit contains one LP Conversion Kit # 576-969 6) Remove the pilot shield by removing 2 screws. Conversion Kit Contains: Qty.
INSTALLATION 15) Turn control knob to the “OFF” position. 20) Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o-ring visible (Fig. 5). 16) Remove the black protection cap by hand from the hi-low knob (Fig.1). 21) Re-assemble the black protection cap (Fig. 6). Red o-ring visible Fig. 1 Cap LPG Configuration Fig.5 17) Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig.
INSTALLATION DC SPARKER BATTERY REPLACEMENT DC Sparker Battery Replacement 1) Remove the battery cover from the DC Sparker - remove the AA battery. 2) Replace with a new 'AA' battery and reinstall battery cover.
INSTALLATION BRICK PANEL INSTALLATION Dangerous operating conditions may occur if the panels are broken. Handle with care. DO NOT FORCE INTO POSITION. 1) Unwrap the Brick Panels from the protective wrapping. 2) Ensure that the logs are not in the unit. Top Panel Back Panel Right Panel Left Panel 3) Remove the heat deflector (if installed) by removing the 2 screws securing the heat deflector from the top of the firebox. 5) Remove the hex head screw on the upper left side of the firebox wall.
INSTALLATION OPTIONAL STAINLESS STEEL / BLACK ENAMEL PANEL INSTALLATION Before installation, panels must be handled and cleaned as per instructions noted below: Stainless Steel Panels Black Enamel Panels • Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. • Black Enamel panels must be inspected for scratches and dimples prior to installation.
INSTALLATION 4) Remove 1 screw (see inset A), position right side panel in firebox position panel clip in place and secure with 1 screw (see inset B). Tighten the screw. 2) Install the back panel first - use care when clearing the burner assembly and rear log tray, so panel is not scratched. Location of hex head screw 4" A Diagram 3 3) Install the top panel next - slide the panel in over top of the back panel - orient the panel so the fold in the metal faces in (see inset A).
INSTALLATION LOG SET INSTALLATION Installation of Optional Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. 2) Spread vermiculite along the base of the firebox. Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
INSTALLATION E B A B 5) Place Log A on the front right side of the burner. Position the notch on the bottom right side of the log into the right side of the grate. 6) Position Log D with the flat side toward Log E. Fit Log D into right peg on Log E. Slide Log A back towards Log E until the flat surface on Log A rests up against the tabs on the burner and grate - this maintains a necessary gap between Logs A & E. Note: Use the notch on the bottom of Log A as a guide -see below.
INSTALLATION 8) Place the lava rocks on the front of the burner tray in the places shown in the photo. Separate platinum embers and place on the front of the burner tray in and around the lava rocks. Avoid stacking platinum embers. Platinum embers may be placed over burner ports. E D B C A Platinum Embers Lava Rocks 10) Test fire to ensure proper light off (make sure flame flows smoothly from one end of the burner to the other).
INSTALLATION Optional WALL THERMOSTAT A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use table below to determine the maximum wire length. Note: Preferable if the thermostat is installed on an interior wall. Regency® offers an optional programmable thermostat but any 250-750 millivolt rated nonanticipator type thermostat that is CSA, ULC or UL approved may be used. CAUTION Do not wire millivolt wall thermostat wires to 120V wire.
INSTALLATION OPTIONAL FAN INSTALLATION Important: 120 Volt AC power is needed for the fan switch and blower. The receptacle box will be installed on the left hand side of the unit and will need to be wired by a qualified electrician prior to fan assembly being installed. The neutral (wider) slot of the polarized receptacle should be at the top. Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances. 1) Shut the power off.
INSTALLATION AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a more yellow flame. CAUTION: Carbon will be produced if air shutter is tightly closed. Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty. Minimum Air Shutter Opening: Air shutter rod - located to the left of the valve assembly.
INSTALLATION #8 Ground Lug (for mobile home) Electrode Thermocouple Thermopile Nut Star washer Gas Pilot WIRING DIAGRAM FOR NG AND LP UNITS Optional Fan Fan Ground Neutral 120V AC 60 Hz Live Ground ON Green OFF Black Pilot Assembly Lockwasher Brown White OFF ON To Thermocouple IN PILO T H (To TH) T-Stat O I (To THTP) White Black DC Spark Box L Ground Red Minimum Convection Air Temp. Switch Rotary Speed Control Fan ground wire Burner ON OFF Red Gas In "S.I.
INSTALLATION 584 Proflame GT Series Feature Sheet 1 1 1 (X) Indicates Included Feature Note 1 ~ Proflame Flame Modulator for GTM & GTMF Remote Controls are sold seperately. Choice of NG or LP flame modulator (to match unit fuel type). See Regency Retail Price pages for complete details Note: Regency Proflame systems include a white and black wall cover & switch.
INSTALLATION OPTIONAL ACCENT LIGHT INSTALLATION B36XT/B36XTE Accent Light Kit # 576-959 1 Light Assembly -includes cable tie/ gasket. 1 910-997 Halogen Bulb 1 940-363 Amber glass 1 910-199 Adhesive wire clip 1 918-821 Instruction Sheet Important: 120 Volt AC power is required to operate the light. The receptacle box will be installed on the left hand side of the unit and will need to be wired by a qualified electrician prior to the light installation.
INSTALLATION 12) After the wiring has been connected, secure green ground wire to ground lug as shown below. Ground lug is located on the lower left corner inside the bottom of the unit. 15) Install the halogen bulb supplied with the kit. Important: Use caution - do not touch the bulb during installation. Use the plastic packaging as a protective covering while installing the bulb. 16) Install a gasket over top of the bulb.
INSTALLATION BULB REPLACEMENT 18) Reinstall the logs. 19) Reinstall glass door and bottom louver / full screen doors. 1) Follow steps 1- 4 from previous page. 20) Plug the light assembly into the receptacle located on the bottom left side of the unit. 2) Remove 2 screws to remove light diffuser plus gasket. 3) Replace the bulb - do not touch bulb with bare hands, use gloves or bulb packaging to protect bulb. Ground Wire Receptacle 21) Turn on electrical supply - test lights.
INSTALLATION FLUSH GLASS DOOR INSTALLATION 1) Line up slots on flush glass door with tabs in firebox. Hook slots on to tabs and lower door slowly (See Diagram 1). Tabs in Firebox Diagram 1 2) Lower the flush door, then hook the 2 adjustable tension latches - close the latches to secure the flush door(See Diagram 2). Adjustable Tension Latch location Diagram 2 Note: To remove Flush Glass door reverse Steps 1 and 2.
INSTALLATION OPTIONAL FINISHING TRIM INSTALLATION NOTE: Install the Finishing Trim prior to installing the Flush Louvers. Finishing Trim Top 1) Install the Finishing Trim sides as shown in the diagram; line up the holes in the 2) 3) 4) side trim with the holes in the firebox side. Secure with 2 screws per side. Loosen the 2 screws in the top inside edge of the firebox. Slide the Finishing Trim Top over the Side Trim pieces and fit the bottom bracket slots over the screws.
INSTALLATION FULL SCREEN ARCH DOOR AND FRAME INSTALLATION 1) Remove glass door (refer to glass door removal in the manual). 2) Install 4 Phillips screws (supplied with packaging) to the inside walls of the unit (see Diagram 1 for locations). Do not tighten the screws - leave them loose for the next step. 5) Reinstall glass door. b) Line up the tabs on top louver with the brackets on the unit. 6) Install bottom mesh door . c) Hook the tab on the top louver over the bracket to install.
OPERATING INSTRUCTIONS INSTALLATION OPERATING INSTRUCTIONS LIGHTING PROCEDURE 1) Read and understand these instructions before operating this appliance. IMPORTANT To ignite or reignite the pilot, you must first remove the glass door. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass in the glass door frame is properly positioned. Never operate the appliance with the glass removed.
OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261) WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged. 2) Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fireplace glass cleaner.
MAINTENANCE REMOVING VALVE 8) Disconnect the inlet gas line. (see Diagram 4) 1) Shut off the gas and electrical supply. 2) Remove the louvers 3) Open the flush door and remove the door. 4) Remove the logs. Diagram 8 5) Remove the burner/grate assembly by removing the 2 Phillips head screws. Diagram 4 9) Disconnect the wall switch wires from the valve. (see Diagram 5) INSTALLING VALVE 1) Place new valve tray into position 2) Reinstall the 8 hold down screws.
PARTS LIST MAIN ASSEMBLY Part # Part # Description 1) 2) 3) 4) 5) 6) 7) 8) 576-084F 576-099 556-524 556-095 556-097 556-513 556-088F 556-094 Top Insulation Plate Top Insulation Flue Collar Outer Assembly Flue Collar Gasket Exhaust Gasket Flue Collar Inner Assembly Top Relief Plate Relief Gasket - Door Top 18) 19) 9) 576-901 576-902 576-904 576-907 576-908 Brick Panel - Standard Brown Brick Panel - Standard Red Brick Panel - Castle Stone Stainless Steel Panels Black Enamel Panels 10) 11) 12) 13) 8
PARTS LIST MAIN ASSEMBLY 1 2 3 4 5 13 6 7 8 16 17 12 14 15 10 11 19 18 23 9 20 22 21 FAN SWITCH ASSEMBLY 64 Regency Bellavista™ B36XT Gas Fireplace
PARTS LIST BURNER ASSEMBLY Part # Description 1) 576-077 Rear Log Tray 3) 4) 576-525 576-057 B36XT Burner Assembly B36XT Grate Assembly 5) 904-644 904-645 910-568 Orifice # 35 NG Orifice # 51 LP Valve NG/LP SIT High/Low 820 6) 7) * Part # 9) 576-574/P 576-576/P 10) 910-038 910-039 910-386 910-341 Description Valve Assembly - NG Valve Assembly - LP Pilot Assembly - NG Pilot Assembly - LP Thermocouple Thermopile Valve Tray - B36XT 65 Regency Bellavista™ B36XT Gas Fireplace
NOTES 66 Regency Bellavista™ B36XT Gas Fireplace
WARRANTY Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product. This warranty is not transferable.
Register your Regency® warranty online www.regency-fire.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.