Instruction Manual

Regency Bellavista™ B41XTCE Gas Fireplace
29
INSTALLATION
V1
H1
H
V
H
H1
V
HORIZONTAL TERMINATIONS
TWO (2) 90
O
ELBOWS (RIGID PIPE 5" X 8")
HORIZONTAL TERMINATIONS
THREE (3) 90
O
ELBOWS (RIGID PIPE 5" X 8")
One 90
o
elbow = Two 45
o
elbows.
Option V H + H1
With these options,
maximum total pipe
length is 30 feet with
minimum of 6 feet total
vertical and maximum 8
feet total horizontal.
Please note minimum
1 foot between 90
o
elbows is required.
A) 0' Min. 2' Max.
B) 1' Min. 3' Max.
C) 2' Min. 4' Max.
D) 3' Min. 5' Max.
E) 4' Min. 6' Max.
F) 5' Min. 7' Max.
G) 6' Min. 8' Max.
No Vent Restrictor Installed
Lengths do not include elbow indicated.
Must use rigid pipe adaptor #770-994.
One 90
o
elbow = Two 45
o
elbows.
Option V
H
V + V1 H + H1
With these
options, maximum
total pipe length
is 30 feet with
minimum of 6 feet
total vertical and
maximum 8 feet
total horizontal.
Please note mini-
mum 1 foot be-
tween 90
o
elbows is
required.
A) 0' Min. 1' Max. 1' Min. 2' Max.
B) 1' Min. 2' Max. 3' Min. 3' Max.
C) 2' Min. 2' Max. 5' Min. 4' Max.
D) 3' Min. 2' Max. 7' Min. 5' Max.
E) 4' Min. 3' Max. 9' Min. 6' Max.
F) 5' Min. 4' Max. 10' Min. 7' Max.
G) 6' Min. 5' Max. 11' Min. 8' Max.
H) 7' Min. 6" Max. 12' Min. 9' Max.
No Vent Restrictor Installed
Lengths do not include elbow indicated.
Must use rigid pipe adaptor #770-994.