Regency Bellavista™ B41XT Gas Fireplace
INSTALLATION
The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system.
A vent guard should be used whenever the termination is lower than the speci ed minimum or as per local codes.
For horizontal terminations the Regency Direct Vent Flex System may be used for installations upto a maximum continuous vent length of 10ft (3.0m).
Note: Must use optional rigid pipe adaptor (Part # 770-994) when using Rigid Pipe vent systems.
Maintain clearance to combustibles.
Horizontal vent must be supported every 3 feet.
Firestops are required at each oor level and whenever passing through a wall.
2
0
12
6
4
8
10
2
0
6
4
8
Vertical Height (Feet)
Rigid or Flex
47-1/2" (1.2m)
Horizontal (Feet)
Max. 36”(0.9m)
Vertical Height (Feet)
28 - 1/2"(0.7m)
Horizontal (Feet)
Max. 36"(0.9m)
Vent Restrictor - Set 1
Factory Setting - No Restrictor Required
VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS
FLEX VENT OR RIGID PIPE 5" X 8"
REAR VENTING DEFLECTOR INSTALLATION
FOR REAR VENTED HORIZONTAL TERMINATIONS
Rear Venting De ector
The Rear Vent De ector comes with the unit. When the unit is shipped
the de ector is slightly tucked underneath the top nailing strips located
at the top of the rebox.
NOTE: The Rear Venting De ector must be installed before the unit is
put in place.
IMPORTANT
Must use Rear Venting De ector packaged with unit in
rear vent horizontal termination applications.
Rear Venting
Deflector
1) Secure the rear venting
de ector to the wall thimble
using 2 screws as shown.
Ensure to use the same screw
holes as the wall thimble.