INSTALLATION
MINIMUM FIREPLACE CLEARANCES TO COMBUSTIBLES
Diagram shows the minimum clearances to any combustible material. Installer must check that all installs maintain at least these clearances..

PP

PP

PP

PP

PP

PP

PP

PP

PP

PP

PP


PP
The minimum clearance from the side of the appliance to a combustible
side wall is 6" (229mm). The minimum clearance from the bottom edge
of the front trim above the window to a combustible mantel is 17- 7/8 "
(454 mm). The minimum height from bottom edge of the front trim above
the window to the ceiling is 37-7/8"(962 mm).
Note: A non-combustible mantel and framing may be installed
at a closer tolerance if the framing is made of metal studs
covered with a non-combustible board.
