U32E-5 FPI Direct Vent Gas Insert
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The FPI Gas Insert must be installed in
accordance with these instructions. Carefully
read all the instructions in this manual rst.
Consult the building authority having jurisdiction
to determine the need for a permit prior to starting
the installation.
NOTE: Failure to follow the instructions could
cause a malfunction of the heater which could
result in death, serious bodily injury, and/
or property damage. Failure to follow these
instructions may also void your re insurance
and/or warranty.
FOR YOUR SAFETY
This appliance requires air for proper combustion.
Always provide adequate combustion and
ventilation air. Follow instructions and
information in CAN/CGA B149 (in Canada) or
the National Fuel Gas Code ANSI Z223.1 (in the
USA), regarding requirements for combustion
and ventilation air.
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit
must be disconnected.
Gas Input Capacity:
Natural Gas 30,000 Btu/h
Propane 27,000 Btu/h
Min. Input
Natural Gas 19,500 Btu/h
Propane 22,000 Btu/h
Fuels: Approved for use with both natural gas,
and propane. Approved as is for use at 0' to
4,500' (0-1370m).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 110 CFM.
Log Set: Ceramic bre, 7 per set.
Vent System: 3" co-linear aluminum ex.
The ef ciency rating of the appliance is a
product thermal ef ciency rating determined
under continuous operating conditions and was
determined independent of any installed system.
GAS PRESSURE
TESTING
The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual
shut off valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than
1/2 psig. (3.45 kPa).
INSTALLATION INTO A
SOLID FUEL BURNING
FIREPLACE OR
FACTORY BUILT
FIREPLACE
The U32E-5 Gas Inserts have been tested and
approved to be vented into any masonry replace
or approved solid fuel burning factory built replace
that will allow the insert to physically t into the
rebox. Refer to "Minimum Fireplace Dimensions"
section for minimum replace clearances.
If the factory built replace* height is too low for
your Insert, you may remove the smoke baf e
plate, damper, refractory ( rebricks), glass doors,
screen rails, screen mesh and log grates from the
factory built replace as long as these items are
saved and are reinstalled in the event that the
Insert is removed.
Smoke shelves, shields and baf es may be
removed if attached by mechanical fasteners. If any
part is removed it must not weaken the structural
integrity of the factory built replace.
NOTE: Any alterations made to the listed solid fuel
burning factory built replace may void the listing
of the replace.
*Check with your local inspector before commencing
with this installation.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI Stand-
ards to make you aware of the following:
General Safety Information
1) The appliance installation must conform
with local codes or in the absence of local
codes, with CAN/CGA B149 (in Canada) or
the National Fuel Gas Code ANSI Z223.1 in
the U.S.A. This appliance should be installed
by a quali ed gas tter technician only.
2) Installation and repair should be done
by a quali ed service person.
3) The appliance should be inspected before
use and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint from
carpeting, bedding material, animal hair, etc.
It is imperative that control compartments,
burners and circulating air passageways of
the appliance be kept clean.
4) See general construction and assembly
instructions. This appliance may only be
installed in a vented, noncombustible
replace.
5) This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) Always connect this insert to a vent system
venting to the outside of the building
envelope. Never vent to another room or
inside a building. Make sure that the vent
is properly sized and is of adequate height
to provide the proper draft.
7) Inspect the venting system annually for
blockage and any signs of deterioration.
8) Any glass removed for servicing must be
replaced prior to operating the appliance.
9) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
replace.
10) Due to high temperatures, the appliance
should be located out of high traf c areas
and away from furniture and draperies.
Children and adults should be alerted to
the hazards of high surface temperatures,
especially the replace glass and gold
trims, and should stay away to avoid burns
or clothing ignition. Young children should
be carefully supervised when they are in
the same room as the appliance. Clothing
or other ammable material should not be
placed on or near the appliance.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
Installer must mechanically attach the supplied
label to the inside of the rebox of the replace
into which the gas replace insert is installed.
"WARNING: This fireplace has been
converted for use with a gas replace insert
only and cannot be used for burning wood or
solid fuels unless all original parts have been
replaced, and the replace re-approved by
the authority having jurisdiction."