Manual

26
E33 FPI Direct Vent Gas Insert
INSTALLATION
1) Align the left side Faceplate Trim Bracket
with the Firebox Flange and secure using
2 screws as shown in diagram 1. Repeat
for right side.
Faceplate
Trim Bracket
Firebox
Flange
IMPORTANT NOTE:
When using the Surround, the unit must be set
1" further into the replace than the standard
faceplate installation. See the "Minimum
Fireplace Opening Excalibur Option" section.
Diagram 1
2) Push the Blanking Plate down on top of the
Glass Door (refer to Diagram 2).
Blanking Plate
Top of
Glass
Door
EXCALIBUR
®
SURROUND
6) Place Bottom Frame near hinge. Flip hinge
over Bottom Frame and secure with 3 screws
each.
5) Install Spring Hinges to the Left and Right
Side of the bottom of the rebox using 2
screws per hinge.
Bottom
Frame
Hinge Location
7) Install the Left and Right Side Screen Doors
by placing over top of the hinges on the
faceplate. Hold the door at a 45 degree
angle to avoid scratching the faceplate.
8) Close screen doors.
Hinge
Screen Door
3) Hold the Faceplate Trim up against the
unit in order to make the following wire
connections.
3a) Pull the ON/OFF connector wires from the
rebox and connect them to the switch.
3b) Connect the fan switch wires with the wire
connectors from the fan speed control. Place
clips over wires and tuck into side trim.
4) Secure the Faceplate by sliding the slots in
the Faceplate into the anges on the left and
right side Faceplate Trim Brackets. Once the
Faceplate is in place secure using 2 screws
per side.
Faceplate
Slots
Faceplate
Trim Bracket
NOTE: If you are installing the Excalibur
®
,
the minimum replace dimensions are
as follows:
Width (at front): 34-1/2" (876mm)
Depth: 17-3/4" (451mm)
Height: 26" (660mm)
Diagram 2