MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Please read the section below carefully as the clearance depend on whether the airmate
or the rear heat deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner,
and from the rear heat shield to a back wall.
Residential Installation Clearances to Combustible Walls
Unit From Unit From Corner From Flue Center-Line
A B C D E F
Medium F2400M with Rear Deflector* 450mm 150mm 225mm 755mm 315mm 555mm
Australia
Rear firebox shield extension fitted, and full length half perforated decromesh flue surround or 900mm long
half round enamelled mild steel flue shield fitted.
New Zealand
Rear firebox shield extension fitted, and full length stainless steel shield with heat dispersal cap fitted to
flue shield top.
Flue systems tested:
Acorn Special Insulated
FLOMET Super Single
Shamic 1A
Masport (NZ)
Floor Protector:
6mm thick fibre cement sheet underneath heater extending 300mm in front and 200mm from the sides of the firebox
opening.
IMPORTANT
Use only the instructions and clearance dimensions on this page for
heaters to be installed in Australia and New Zealand.
The Masport F2400M has been tested by the AHHA Testing Laboratory
and conforms to AS/NZS 2918:200, Report No. ATL19-04.
AUSTRALIA & NEW ZEALAND ONLY
The Masport F2400M has been tested with the flue kits listed
below. A default flue kit as listed in AS/NZS 2918:2001 may also
be used.
These are the only flue kits certified for use with this heater for
installation in Australia and New Zealand.