MAINTENANCE
Annual Maintenance
Completely clean out entire unit Annually
Inspect air tube, Catalytic Combustor and bricks Replace any damaged parts.
Adjust door catch assembly If unable to obtain a tight seal on the door - replace door gasket seal.
Readjust door catch after new gasket installed.
Inspect condition and seal of:
Glass Gasket
Door Gasket Perform paper test - replace gasket if required
Paper Test Test the seal on the loading door with a paper bill.
Place a paper bill in the gasket area of the door on a cold stove.
Close the door.
Try to remove the paper by pulling.
The paper should not pull out easily, if it does, try adjusting the door latch, if that
doesn't solve the problem replace the door gasket.
Check and lubricate door hinge + latch Use only high temperature anti seize lube. (ie. never seize)
Check glass for cracks Replace if required.
Clean blower motor Disconnect power supply.
Remove and clean blower.
*DO NOT LUBRICATE*
Inspect and clean chimney Annual professional chimney cleaning recommended.