Installation manual

F5100 Regency Freestanding Woodstove
9
INSTALLATION
8
8
8
8
FLOOR PROTECTION
A combustible fl oor must be protected by non-combustible
material (like tile, concrete board, or certifi ed to UL-1618 or
as defi ned by local codes) extending beneath the heater and
a minimum of 8" (203mm) from each side and minimum 16"
(406mm) from the front face of the stove and minimum 6"
(or the rear clearance to combustibles whichever is smaller)
from the rear of the stove.
When installed with horizontal venting, non-combustible fl oor
protection must beneath the fl ue pipe and extend 2" (51mm)
beyond each side.
Minimum Overall Width (X) of Floor
Protector for all installations:
Stove F5100 45" (1143 mm)
NOTE: In Canada, fl oor protection must extend 18" (450mm) to the front
and 8" (203mm) to each side and back of the stove.
Minimum Overall Depth (Y) of Floor Protector
Unit Residential
Close Clearance
Mobile Home
Close Clearance
Alcove
F5100
YZ
Y
Z
Y
Z
USA
49-1/8" 8" 49-1/8" 8" 49-1/8" 8"
Canada
53-1/8" 8" 53-1/8" 8" 53-1/8" 8"
The rear clearance to combustibles is less than 6" (for corner installations the rear corners may
be angled to take advantage of the closer clearances.