Operating instructions

Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace 13
FLUEING ARRANGEMENT - HORIZONTAL TERMINATIONS
Regency Direct Vent System (Flex) Horizontal Terminations Only
These ueing systems, in combination with the PG121-1 / PG121LC-1 / PG121RC-1 / PG131-1 Direct Vent Gas Fireplace, have been tested and
listed as a direct ue heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Flue Terminal
Locations diagram.
Regency Direct Vent (Flex) System Termination Kit (Part# 946-513) includes all the parts needed to install the PG121-1 / PG121LC-1 /
PG121RC-1 / PG131-1 with a maximum run of 2 feet.
1) 6-7/8" dia. exible liner (2 ft. length)
2) 4" dia. exible liner (2 ft. length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" drill point, stainless steel (4)
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
3) Regency Direct Vent System (Flex) is only approved for horizontal terminations.
INSTALLATION