Operating instructions

Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
22
INSTALLATION
Conversion Kit# 360-968 from NG to LPG
1) Shut off the gas supply and unplug the
power cord.
2) Remove louvers and trim.
3) Carefully remove the glass, logs and lava
rock.
4) Remove the grate by lifting straight up.
Remove the side brick panels (if in-
stalled). The brick panel is very fragile
- handle with care.
5) Remove the burner assembly by removing
the 4 Phillips head screws and then slide
the burner assembly away from the orifi ce
and lift out.
6) Remove burner orifi ce with a 1/2" spanner
and discard. Use another spanner to hold
on to the elbow behind the orifi ce.
11) Check the areation (10mm open) for the
LPG burner and install the burner, grate
and logs.
12) Remove the front cover by undoing the 2
screws.
Front Cover
13) Stick the conversion label "This unit has
been converted to LPG" over top of the
serial number decal.
14) Replace the yellow "NG" label with the red
"LPG" label.
15) Carefully pull out the control box from un-
derneath the fi rebox.
Note: The control box is held in place with
velcro.
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Conversion Kit contains:
Qty. Part # Description
1 904-529 5/32" Allen Key
1 904-641 Burner Orifi ce #50
1 918-590 "Converted to LPG" label
1 908-528 Red "LPG" label
1 910-037 #30 ULPG Pilot Orifi ce
1 918-578 Instruction Sheet
Burner Orifi ce
8) Pull out the pilot hood by hand.
Pilot Hood
9) Remove the pilot
orifi ce with the
allen key.
Pilot Hood
Removed
Pilot
Orifi ce
10) Put in the new LPG orifi ce with the allen key.
Then put back the pilot hood.
7) Reinstall new burner orifi ce LPG stamped
#50 and tighten.