Owners & Installation Manual Freestanding Woodstoves Medium Freestanding Woodstove with optional Gold Legs. Medium Freestanding Step Stove with Pedestal Base. MODELS: Tested by: 908-288 F1100S F2100M F3100L S2100M S3100L Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St.
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning. SAFETY NOTE: If this woodstove is not properly installed, a house fire may result.
TABLE OF CONTENTS THE REGENCY FREESTANDING STOVE SAFETY LABEL Door Handle ...................................................................... 17 Glass Installation .............................................................. 17 Small Freestanding Stove F1100S ..................................... 4 Optional Accessories Medium Freestanding Stove F2100M ................................. 5 - Pedestal Ash Drawer Kit .......................................... 17 Large Freestanding Stove F3100L .......
SAFETY LABEL This is a copy of the label that accompanies each Regency Small Freestanding Woodstove (F1100S). It is located in the upper right corner of the back of the stove. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
SAFETY LABEL corner of the back of the stove. We have printed a copy of the contents here for your review. MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT MAXIMUM ALCOVE DEPTH 915 MM / 36 IN. MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18" THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.
SAFETY LABEL of the back of the stove. We have printed a copy of the contents here for your review. F BACK M FLOOR PROTECTION* K 405 mm / 16 in L 150 mm / 6 in M 150 mm / 6 in MADE IN CANADA CERTIFIED TO COMPLY WITH JULY 1990, PARTICULATE EMISSION STANDARDS. CAUTION HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS. WD 908-351 01/03 2003 FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 VENTURE ST.
SAFETY LABEL This is a copy of the label that accompanies each Regency Medium Freestanding Step Woodstove (S2100M). It is located in the upper right corner of the back of the stove. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
SAFETY LABEL This is a copy of the label that accompanies each Regency Large Freestanding Step Woodstove (S3100L). It is located in the upper right 8 corner of the back of the stove. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
INSTALLATION RESIDENTIAL INSTALLATION 1) Read all instructions before installing your Regency Stove. Install and use only in accordance with these installation and operating instructions. Be aware that local Codes and Regulations may override some items in this manual. Check with your local inspector. 2) Select a position for your Regency Stove. Consult the minimum clearance chart for your model and set the stove in place.
INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Please read the section below carefully as clearances depend on whether the airmate or the rear heat deflector is installed on the stove. Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall. Residential Installation āCā Vent (Single Wall) Unit From Unit From Corner From Flue Center-line A B C D E F with Airmate with Rear Deflector 13" 15" 11" 10.
INSTALLATION Minimum Alcove Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 84" Maximum depth of alcove - 36" Unit From From Flue Min. Min.Hearth Unit Center-line Width to Rear Wall G H I J K L Small F1100S with Airmate with Rear Deflector 11" 13" 7" 5" 23" 25" 13.5" 11.
INSTALLATION STOVE ASSEMBLY PRIOR TO INSTALLATION Rear Heat Deflector Assembly for F1100, F2100, and F3100 All units require either the pedestal or 4 legs attached to the base. The F1100, F2100, and F3100 stoves require either the Airmate or Rear Heat Deflector on top of the stove. Clearances to combustible materials vary depending on whether the airmate or rear heat deflector is installed, so be sure to check the clearance information on pages 10 and 11.
INSTALLATION Leg and Bottom Shield Assembly Bottom Shield Small Medium Large 850-121 850-221 850-321 Legs (set of 4) Steel - Painted Black 850-125 Cast - Painted Black 850-126 Cast - Gold Plated 850-127 The instructions below apply to the steel leg, painted cast leg and the gold plated cast leg. It will be easier to attach the legs to the stove if it is tipped on its back (preferably on a soft surface to prevent scratching). 1) Remove the 4 bolts in the underside of the base and discard.
INSTALLATION TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET (Measured from the top of the unit) # OF ELBOWS ELEVATION (FT) ABOVE SEA LEVEL 0 0-1000 1000-2000 2000-3000 3000-4000 4000-5000 5000-6000 6000-7000 7000-8000 8000-9000 9000-10000 12.0 12.5 13.0 13.5 14.0 14.5 15.0 15.5 16.0 16.5 2 x 15o 4 x 15o 2 x 30o 13.0 13.5 14.0 14.5 15.0 15.5 16.0 16.5 17.0 17.5 14.0 14.5 15.0 15.5 16.0 17.0 17.5 18.0 18.5 19.0 15.0 15.5 16.0 17.0 17.5 18.0 18.5 19.0 20.0 20.5 4 x 30o 2 x 45o 4 x 45o 18.0 19.0 19.
INSTALLATION LISTED COMPONENTS FOR MOBILE HOME INSTALLATION The Regency Small, Medium, Medium Step and Large Freestanding pedestal units are approved for installation in a Mobile Home if one of the following pipe systems is used. U.S. Installation* METALBESTOS SSII Qty. Part # Description 1 6DS-VK Connector Kit 1 6TMH Shield/Support 1 6TAF-6 Flashing 1 6T-36 Chimney Length 1 6T-18 Chimney Length 1 6T-CT Rain Cap PRO-JET 3103 Qty.
INSTALLATION 4) Install the two front air tubes into the holes on the side channels. The notch goes on the right hand side with the air holes facing forward toward the door opening. If the tube will not slide in easily, simply use a pair of vise grips or pliers and tap it into place with a hammer. A tighter fit will ensure the tube will not move when the unit is burning. manner as Step 1) above. Then reposition the left baffle brick flat on the air tubes.
INSTALLATION BRICK INSTALLATION DOOR HANDLE Firebrick is included to extend the life of your stove and radiate heat more evenly. Check to see that all firebricks are in their correct positions and have not become misaligned during shipping. Attach spring handle by rotating counter clockwise onto rod. Ensure that the rod fits into the entire length of the spring handle. See Diagram below. Pedestal Ash Drawer Kit (850-100) 1) Remove the bricks from the floor of the firebox.
INSTALLATION Blower/Fan (846-515) 1) Remove the two screws from the top of the fan housing. 2) Slide the fan up into the rear heat shield. 3) After aligning holes, secure the fan to the rear heat shield using the two screws removed earlier. Note: The connection cord should not be in contact with any hot surfaces. Read the operating instructions for the fan before using. See Page 19.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority, you are now ready to start a fire. Before establishing your first fire, it is important that you fully understand the operation of your draft control. DRAFT CONTROL Both the primary and air wash drafts are controlled by the control rod located on the left side of the unit (when facing the unit). To increase your draft - pull open, and to decrease - push closed.
OPERATING INSTRUCTIONS ASH DISPOSAL During constant use, ashes should be removed every few days. The Ash Drawer option features a convenient ash dump for easy removal of ash, see "Modular Options" on page 9. Bottom Shield (with Legs) Units: To remove the drawer, lift slightly and slide it out, and carry it away. 8) The stove consumes air while operating, provide adequate ventilation with an air duct or open a window while the stove is in use.
MAINTENANCE CREOSOTE LATCH ADJUSTMENT GLASS MAINTENANCE When wood is burned slowly, it produces tar and other organic vapours, which when combined with moisture, form creosote. The creosote vapours condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote can result in an extremely hot fire. The door latch may require adjustment as the door gasket material compresses after a few fires.
PARTS LIST F1100 & F3100 STOVE MAIN ASSEMBLY Part # Description 1) 846-913 846-915 846-910 846-916 Door Door Door Door 3) 846-302 846-304 936-243 846-920 * 948-170/P 948-172/P 846-973 820-375 * 820-376 * 846-570 846-918 948-101 948-102 846-515 Glass - Replacement - Small/Medium F1100 Glass - Replacement - Large F3100 7/8" Adhesive Tape Gasket Glass Retainer Clips (8/set) Screw - 1/4 - 20 x 3/8" Small Glass Retainer F1100 Large Glass Retainer F3100 Door Handle Assembly Ash Hole Cover Plate Bolt 1/4 -
PARTS LIST F2100 STOVE MAIN ASSEMBLY Part # 1) 3) 4) 5) 6) 7) 9) 12) 13) 14) 15) 16) 17) 19) 20) Description 846-913 846-915 Door Assy-Med Gold F2100 (no glass) Door Assy-Med Black F2100 (no glass) 846-302 936-243 846-920 * 948-170/P 846-973 820-375 * 820-376 * 846-570 846-918 948-101 948-102 Glass - Replacement - Medium F2100 7/8" Adhesive Tape Gasket Glass Retainer Clips (8/set) Screw - 1/4 - 20 x 3/8" Small Glass Retainer F2100 Door Handle Assembly Ash Hole Cover Plate Bolt 1/4 - 20 x 1/2 Hex Head
PARTS LIST S2100 & S3100 STEP STOVE MAIN ASSEMBLY Part # 1) 3) 4) 5) 6) 7) 8) 9) 16) 846-913 846-915 846-910 846-916 846-302 846-304 936-243 846-920 * 948-170/P 948-172/P 130-006 130-005 150-006 150-005 846-973 846-570 Description Door Assy- Medium Gold S2100 (no glass) Door Assy-Medium Black S2100 (no glass) Door Assy-Large Gold S3100 (no glass) Door Assy-Large Black S3100 (no glass) Glass - Replacement - Medium - S2100 Glass - Replacement - Large - S3100 7/8" Adhesive Tape Gasket Glass Retainer Clips
PARTS LIST PEDESTAL, BOTTOM SHIELD & LEG OPTIONS Part # 48) Description 49) 50) 850-115 850-215 850-315 904-257 * Pedestal - Small Pedestal - Medium Pedestal - Large Large Magnet Catch Blanking Plate - Pedestal 45) 46) 58) 59) 850-100 * * 942-110 820-249 Ashdrawer Kit - Pedestal Ashdrawer - Pedestal Ashdrawer Lid Assy Ash Plug Ash Plug Tool Handle 57) 850-121 850-221 850-321 * Bottom Shield - Small Bottom Shield - Medium Bottom Shield - Large Blanking Plate - Btm Shield 55) 58) 59) 850-101 * 942
PARTS LIST FIREBRICK Part # Description 70) 71) 72) 73) 74) 902-111 802-104 802-122 802-146 802-147 Brick Brick Brick Brick Brick - Regular Full Size: 1-1/4" x 4-1/2" x 9" Partial: 1-1/4" x 4" x 9" Partial: 1-1/4" x 2" x 4-1/2" Partial: 1-1/4" x 1-3/4" x 9" Partial: 1-1/4" x 4-1/2" x 3-1/2" 76) 77) 78) 79) 80) 802-152 802-145 802-149 802-153 802-154 Brick Brick Brick Brick Brick Partial: 1-1/4" x 2" x 9" Partial: 1-1/4" x 3-1/4" x 9" Partial: 1-1/4" x 4-1/2" x 3-1/4" Partial: 1-1/4" x 4-1/2" x 2-1/
WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
Regency fireplace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product. See the inside back cover for details. Register your Regency online at http://www.regency-fire.