OWNER'S MANUAL Owner's manual

Operating Instructions
opeRating youR peLLet Stove:
THE UNIT WILL NOT OPERATE WITH THE DOOR OR ASH BOX OPEN. Open the hopper lid only to re-
fuel or to adjust the controls. the unit will shut down if the hopper lid is left open for longer than
two minutes.
CAUTION: When operating during adverse weather, such as high winds or freezing rain, if the unit exhibits
dramatic changes in combustion stop using the unit immediately. Watch for blocked exhaust outlet.
PRE-BURN CHECK: The burn pot liner holes must be clear and the liner installed properly against the
ignitor tube and locked in place. Check the hopper for enough pellets to start the unit.
Figure 3: Thermostat Switch
in MANUAL position.
Figure 4: Thermostat Switch
in HIGH/LOW position.
Figure 5: Thermostat Switch
in AUTO/OFF position.
Note: To change fuel type, ensure the Thermostat Switch is set to Manual Mode.
Press the Off button and then press the Fuel Type button to cycle through the
available fuel types.
The unit has an automatic cleaning cycle; every thirty (30) minutes the agitator
will turn continuously for one (1) minute to help clean out the burn pot liner.
MANUAL MODE:
All control of circuit board function is adjusted at the circuit board.
INITIAL START-UP: Press the ON / OFF button. The stove will turn on. The Fuel Type Light will flash (the
Auger Feed Rate is pre-programmed during start-up). The Heat Level Indicator will show the Heat Level that
the stove will run at after start-up.
If this is the first time the unit has been started or the unit has run out of fuel, the auger may need to be
primed. If there is no fuel in the burn pot after two (2) minutes
the liner can be primed with a handful of
pellets
.
The agitator will not operate for the first ten (10) minute after the ON button has been pressed. After the ten
(10) minutes it will pulse at the same interval as the feed auger.
When the start-up sequence is complete the unit will ramp up
in two (2) minute intervals until it has reached
the designated heat setting.
Once a fire has been established, the convection blower will turn on after ten (10) minutes.
To OPERATE: Press the Heat Level buttons to change the desired Heat Level Output setting.
The speed of the convection blower is controlled by the setting of the heat level.
The Feed Trim button pressed in conjunction with the Heat Level adjustment buttons
can be used to adjust the
feed trim
. It can be increased by two (2) feed settings or it can be decreased by
two (2) feed settings.
HIGH/LOW MODE: (Requires a Thermostat or Timer)
INITIAL START-UP: See MANUAL MODE above.
OPERATION: When the thermostat calls for heat (contacts are closed) the
stove settings are adjustable as per Manual Mode. When the thermostat
contacts open, the HEAT LEVEL and Fans will drop down to the LOW setting until
the thermostat contacts close again. The stove will come back to the previous
HEAT LEVEL setting once the thermostat contacts close.
AUTO/OFF MODE: (Requires a Thermostat or Timer)
INITIAL START-UP: See MANUAL MODE above.
OPERATION: When the thermostat contacts close, the unit will light
automatically. Once up to temperature, the stove operates the same as in
MANUAL. When the thermostat contacts open, the stove’s HEAT LEVEL and Fans
Sticker Front Sticker Back
AUTO/OFF
HIGH/
LOW
MANUAL
Premium Grade Pellets
Regular Grade Pellets
Low Grade Pellets
1
2
3
4
5
HEAT
LEVEL
COMBUSTION
ON/OFF
FEED TRIM
FAN TRIM
FUEL TYPE
Sticker Front Sticker Back
AUTO/OFF
HIGH/
LOW
MANUAL
Premium Grade Pellets
Regular Grade Pellets
Low Grade Pellets
1
2
3
4
5
HEAT
LEVEL
COMBUSTION
ON/OFF
FEED TRIM
FAN TRIM
FUEL TYPE
Sticker Front Sticker Back
AUTO/OFF
HIGH/
LOW
MANUAL
Premium Grade Pellets
Regular Grade Pellets
Low Grade Pellets
1
2
3
4
5
HEAT
LEVEL
COMBUSTION
ON/OFF
FEED TRIM
FAN TRIM
FUEL TYPE
Hampton GC60 Cast Pellet Stove Owner’s Manual 9