Regency Gem54 Gas Fireplace Owners & Installation Manual MODELS: GEM54-NG GEM54-LPG GEM54-ULPG LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AS4558 / NZS 5262 and have been certified by the Australian Gas Association for installation and operation as described in these Installation and Operating Instructions. Your unit should be serviced annually by an authorised service person. www.regency-fire.com.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The Gem54 has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The model Gem54 has been approved by AGA for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
TABLE OF CONTENTS DATA BADGE Copy of data badge .......................................................4 DIMENSIONS Unit Dimensions ............................................................5 Faceplate & Door frame overlay Dimensions ................5 Conversion from NG to ULPG .....................................30 Aeration Adjustment ....................................................33 Wiring Diagram ...........................................................33 Reflective Panel Installation .......
SAFETY LABEL This is a copy of the badge that accompanies each Gem54™-NG Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency® units are constantly being improved. Check the badge on the unit and if there is a difference, the badge on the unit is the correct one. COPY OF DATA BADGE Regency Gas Fireplace Model Gas Type Model Distributed by: NG Gem54-NG LPG Gem54-LP ULPG Gem54-ULPG Gas Consumption 35.9 mj. 32.2mj. Manifold Pressure 0.88 kPa 2.
DIMENSIONS UNIT DIMENSIONS 52-5/8” (1337mm) 59” (1499mm) 19-3/4” (502mm) 35-1/4” (895mm) 22-3/8” (568mm) 5-11/16” (144mm) 46-3/8” (1178mm) 31-5/8” (803mm) 17-1/8” (435mm) 10-5/8” (270mm) 48-1/2” (1232mm) 1-1/2” (38mm) 20-1/2” (521mm) FACEPLATE & DOOR FRAME OVERLAY DIMENSIONS Regency Gemfire™ Gas Fireplace 5
INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The Gem54™ Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes and complies with a S5601 / AG601 clause 5.
INSTALLATION INSTALLATION CHECKLIST 1) Locate appliance a) Room location (Refer to "Locating Your Gas fireplace" section) b) Clearances to Combustibles (Refer to "Clearances" section) c) Mantle Clearances (Refer to "Mantel Clearances" section) d) Framing & Finishing Requirements (Refer to "Framing & Finishing" section) e) Venting Requirements (Refer to "Venting" section) This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label 41,500 Btu/h, after burning appliance for
INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Caution Requirements The top, back and sides of the fireplace are defined by standoffs.
INSTALLATION NON COMBUSTIBLE FACING BOARD 5-5/8” (143mm) 52-5/8” (1343mm) Non-combustible Facing Board 21-3/4” (554mm) Non-combustible Facing Board Non-combustible Facing Board If finishing the wall above the unit with materials such as tile, brick, marble, etc. non-combustible board available from the building supply store can be used. Timber Stud 20" (508mm) Calcium silicate board is a high - grade material with cement, quartz, natural and selected minerals as the main raw materials.
INSTALLATION (152mm) (102mm) (51mm) 2 (254mm) 4 (305mm) 6 (356mm) 14 12 10 8 Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board. 0 Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right.
INSTALLATION FRAMING & FINISHING 1) Frame in the enclosure for the unit with framing material. IMPORTANT: Header must be metal stud. All other framing may be of combustible type such as 2x4 (0.6m x 1.2m) / 2x6 (0.6m x 1.8m) framing materials. 5) When finishing around the faceplate, if material such as brick, stone, etc. extend past the faceplate depth - the minimum opening dimensions noted below must be adhered to, this is to assure removal of the faceplate.
INSTALLATION Framing Dimensions Description A B Framing Height Framing Width 46-5/8” (1184mm) 60” (1524mm) C* D E F G H I J K L Framing Depth* Minimum Height to Combustibles Corner Wall Length Corner Facing Wall Width Vent Centerline Height Non-combustible facing height Gas Connection Opening Height Gas Connection Height Gas Connection Inset Gas Connection Opening Width 51” (1295mm) 72" (1829mm) 101-7/8 (2586mm) 44” (1118mm) 20” (508mm) 1-1/2” (38mm) 4” (102mm) 7-1/4” (184mm) 3-1/4” (83mm) Gem54 22
INSTALLATION NAILING STRIPS UNIT ASSEMBLY PRIOR TO INSTALLATION The Top Standoff/ Nailing Strip, side nailing strips and standoffs must be correctly positioned and attached to the unit before sliding the unit into position. The nailing strips come attached to the unit. There is 1 plate on each side,1 on the top, and one on the bottom that can be folded out as required. The top and side nailing strips are secured to the framing.
INSTALLATION VENT RESTRICTOR POSITION Vent restriction is required for certain venting installations, see the diagrams in the "Venting Arrangements" section to determine if they are required for your installation. The Vent Restrictor plate is located on the inside top of the firebox. To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions; 1) Remove the glass door. 2) Remove the screws that hold the vent restrictor plate in place.
INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced flue terminals or the flue terminals of outdoor appliances according to AS5601-2004 (AGA gas installation code) or NZS 5262 (New Zealand) and local authorities having jurisdiction.
INSTALLATION VENTING ARRANGEMENTS HORIZONTAL TERMINATION (FLEX) Regency® Direct Vent System These venting systems, in combination with the Gem54, have been tested and listed as a direct vent system by AGA. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section. FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the Gem54 using a flexible vent.
INSTALLATION RIGID PIPE VENTING SYSTEMS BASIC HORIZONTAL & VERTICAL TERMINATIONS Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized finish.
INSTALLATION 5” X 8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.
INSTALLATION Description Attic Insulation Shield 12” Simpson Selkirk Metal-Fab™ ICC Excel Direct Vent Pro® Direct Temp™ Sure Seal Direct 58DVA-IS N/A from FPI N/A N/A N/A Basic Horizontal Termination Kit (A) N/A 5DT-HKA N/A N/A Horizontal Termination Kit (B) 58DVA-KHA 5DT-HKB N/A N/A Vertical Termination Kit 58DVA-VHA 5DT-VKC N/A N/A High Wind Vertical Cap 58DVA-VCH N/A N/A TM-5VT High Wind Horizontal Cap N/A N/A N/A TM-5DHT Horizontal Square Termination Cap N/A 5DT-
INSTALLATION VENTING ARRANGEMENTS ALLOWABLE HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o (two 45o elbows equal one 90o elbow). Note: Must use optional rigid pipe adapter (Part# 770-994) when using Simpson Duravent Venting Systems.
INSTALLATION VENTING ARRANGEMENTS ALLOWABLE HORIZONTAL TERMINATIONS FOR GEM54-LPG/ULPG The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o (two 45o elbows equal one 90o elbow). Note: Must use optional rigid pipe adapter (Part# 770-994) when using Rigid Pipe Venting Systems.
INSTALLATION Horizontal Venting with Two (2) 90o Elbows H1 o H o One 90 elbow = Two 45 elbows. Option A) V .6m Min. V H + H1 1.2m Max. B) .9m Max. 1.8m Max. C) 1.2m Max. 2.4m Max. D) 1.5m Max. 2.7m Max. E) 1.8m Max. 3m Max. With these options, maximum total pipe length is 9m with minimum of 1.8m total vertical and maximum 3m total horizontal. Please note minimum .3m between 90 o elbows is required. VENT RESTRICTOR SETTING: Vent restrictor factory set at Set 1, no adjustment required.
INSTALLATION Vertical Venting with Three (3) 90o Elbows One 90o elbow = Two 45o elbows. Option V H V+ V1 A) .6m Min. .6m Max. 1.2m Min. B) .9m Min. 1.2m Max. 1.8m Min C) 1.2m Min. 1.5m Max. 2.1m Min. D) 1.5m Min. 1.8m Max. 2.4m Min. E) 1.8m Min. 2.4m Max. 2.7m Min. With these options, max. total pipe length is 9m with min. of 2.7m total vertical and max. 2.4m total horizontal. Please note minimum .3m between 90o elbows is required.
INSTALLATION VENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS FOR GEM54-NG Horizontal (Feet) The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbows, with Rigid Pipe Venting Systems for Natural Gas. Two 45o elbows equal to one 90o elbow. Maximum of four 45o elbows allowed. 0 2 4 6 8 10 12 14 16 18 40 Maximum: 40 ft. (12.
INSTALLATION VENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS FOR GEM54-LPG/ULPG Horizontal (Feet) The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbows, with Rigid Pipe Venting Systems for Natural Gas. Two 45o elbows equal to one 90o elbow. Maximum of four 45o elbows allowed. 0 2 4 6 8 10 12 14 16 40 Maximum: 40 ft. (12.
INSTALLATION 7) Ensure that the pipe clearances to combustible materials are maintained (Diagram 3). Install the termination cap. UNIT INSTALLATION WITH HORIZONTAL TERMINATION Note: If installing termination on a vinyl siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.
INSTALLATION UNIT INSTALLATION WITH VERTICAL TERMINATION (Rigid Vent Systems) Note: A clearance of 2"(51mm) must be maintained; except when passing through a wall, ceiling, or at the termination where the use of a firestop or wall thimble reduces the required clearance to 1-1/2" (38mm). We recommend framing a 11"(279mm) x 11"(279mm) (inside dimensions) hole to give structural rigidity for mounting the termination.
INSTALLATION UNIT INSTALLATION (With Horizontal Termination Flex System) Note: A top clearance of 3"(76mm) and side & bottom clearance of 2"(51mm) must be maintained; except when passing through a wall, ceiling, or at the termination where the use of a firestop or wall thimble reduces the required clearance to 1-1/2" (38mm). We recommend framing a 11"(279mm) x 11"(279mm) (inside dimensions) hole to give structural rigidity for mounting the termination.
INSTALLATION Gem54-NG SYSTEM DATA Min. Supply Pressure 1.13 kpa Low Setting Man. Pressure 0.4kpa Max. Manifold Pressure 0.87 kpa Injector Size #32 DMS Minimum Input 26.2 mj Maxiumm Input 35.9 mj Gem54-LPG SYSTEM DATA Min. Supply Pressure 2.74 kpa Low Setting Man. Pressure 1.6 kpa Max. Manifold Pressure 2.49 kpa Injector Size #51 DMS Minimum Input 26.4 mj Maxiumm Input 32.2 mj Gem54-ULPG SYSTEM DATA Min. Supply Pressure 2.74 kpa Low Setting Man. Pressure 1.6 kpa Max.
INSTALLATION CONVERSION KIT # 476-967 FROM NG TO LPG CONVERSION KIT #476-968 FROM NG TO ULPG FOR GEM54™ USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 1) Each Kit contains one LPG Conversion Kit # 476-968 Each Kit contains one ULPG Conversion Kit # 476-967 LPG Conversion Kit Contains: Qty.
INSTALLATION 7) Loosen 6 screws that secure the burner extenders. on burner tray, located behind the burner on either side of the pilot assembly. 11) With burner removed - lift out burner tray. 8) Lift out the 2 burner tray extenders. 12) Pull off the pilot cap to expose the pilot orifice. (see below) Burner tray extenders Burner tray Pilot Orifice Burner tray extenders 9) After extenders have been removed. Remove the 2 screws that secure the burner tray, at the base of the firebox.
INSTALLATION 15) Turn control knob to the “OFF” position. 16) Remove the black protection cap by hand from the high-low knob (Fig.1). 20) Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten. 23) Attach the label "This unit has been converted to LPG (or ULPG)" near or on top of the serial # decal. 24) Replace yellow "NG" label with red "LPG" or ULPG label. 25) Adjust aeration settings according to the fuel type.
INSTALLATION AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a more yellow flame. Minimum Air Shutter Opening: NG LP ULPG CAUTION: Carbon will be produced if air shutter is not fully open. Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.
INSTALLATION OPTIONAL STAINLESS STEEL REFLECTIVE PANEL INSTALLATION Before you start: Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. To protect the finish during installation and handling - cotton gloves MUST be worn at all times while handling the panels (even when removing protective coating). Stainless panels will discolor a little during normal operation.
INSTALLATION GLASS CRYSTALS OR OPTIONAL CERAMIC STONES INSTALLATION ON BURNER Gem54 Glass Crystal/Optional Ceramic Spa Stone Quantity Glass Crystals only *Ceramic Spa Stones 2 bags 1 bag glass crystals + 70 ceramic spa stones * 1 bag of glass crystals must be used on burner when using ceramic spa stones. Evenly spread an appropriate amount of glass crystals (approx. 12mm) or optional ceramic stones over the burner.
INSTALLATION LOG SET INSTALLATION Installation of Reflective Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
INSTALLATION Diagram 5 Pin clips installed - dots indicate dimple locations. *Actual dimples/pin clips are black - not white as shown 4) Install the glass crystals (see glass crystal installation section in this manual). Diagram 6 5) Place platinum embers on glass crystals as shown in diagram 7. Diagram 7 6) If installing optional pebbles - install pebbles before log installation.
INSTALLATION 7) Place logs A + B on the burner, rest logs on the pin clips, as shown in diagram 9. Note: Logs should be oriented exactly as shown in diagram 9. A B A B Diagram 9 8) Place logs C + D on logs A + B, as shown in diagram 10. Note: Logs should be oriented exactly as shown in diagram 10. D D C C Diagram 10 9) Install the following: a) *Glass door b) *Faceplate and door frame *Refer to these sections in the HZ54 manual for detailed instructions.
INSTALLATION SCREEN & DOOR FRAME OVERLAY INSTALLATION Before you start: Stainless must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. To protect the finish during installation and handling - cotton gloves MUST be worn at all times while handling the panels (even when removing protective coating). Stainless will discolor a little during normal operation.
INSTALLATION FACEPLATE INSTALLATION Warning: Turn off the unit by way of the wall switch or remote. Allow unit to cool at least 10 min. - prior to removing the faceplate. 1) Secure the left side mounting bracket to the backside of the fascia as shown below. Use 3 screws supplied to secure the mounting bracket in place. Repeat for left side. 2) Install the fascia to the unit by hooking the left and right side mounting brackets into the mounting slots at the side of the firebox as shown below.
INSTALLATION IMPORTANT NOTE 3a)There are 2 magnets on each side of the top fascia that secure the bottom fascia in place. To ensure the gap between the door frame and the faceplate are equal from side to side you may need to slide the faceplate slightly to the left or right accordingly. Also if necessary, the faceplate may be adjusted up and down by loosening the top screw as shown in the diagram below and sliding the plate up or down as required.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS LIGHTING PROCEDURE 1) Read and understand these instructions before operating this appliance. NOTE: The Gas ON/OFF knob cannot be turned from "ON", "PILOT" or "OFF" unless it is partially depressed. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. Warning: Turn off the unit by way of the wall switch or remote. Allow unit to cool at least 10 min. - prior to removing faceplate. 3) Check to ensure there are no gas leaks.
OPERATING INSTRUCTIONS INSTALLATION COPY OF LIGHTING PLATE INSTRUCTIONS OFF a Regency Gemfire™ Gas Fireplace 43
MAINTENANCE FAN SERVICE PRIOR TO SERVICING THE FAN, ENSURE UNIT HAS COOLED TO ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS SUPPLY IT TURNED OFF. 4) Loosen 6 screws that secure the burner extenders. on burner tray, located behind the burner on either side of the pilot assembly. 5) Lift out the 2 burner tray extenders. 1) Remove the faceplate by lifting it up off the hinges on the sides of the firebox.
MAINTENANCE 9) From the front of the unit, remove the two screws that are securing the fan duct to the unit. Remove the two screws securing the duct to the fan assembly. Set fan duct off to right side closest to gas valve. 15) Carefully disconnect spade connectors. Remove Screws Disconnect ducting both sides. Remove Screws Remove Screws Spade connectors Top View 10) From the fan access outlet within the firebox, remove the screws on the left side of fan securing the flex and bracket.
MAINTENANCE WIRING No electrical power supply is required for the gas control to operate. However, a 240V A.C. power supply is needed for the fan/blower operation. Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. Star washer WARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
MAINTENANCE MAINTENANCE INSTRUCTIONS GENERAL VENT MAINTENANCE 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows: 2) Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner.
MAINTENANCE GLASS DOOR REMOVAL Warning: Turn off the unit by way of the wall switch or remote. Allow unit to cool at least 10 min. - prior to removing faceplate. 5) Remove the glass door. a) Remove the 3 screws shown below at the bottom of the glass door. 1) Turn the unit off and allow it to cool down to room temperature - prior to handling. b) Swing the door out 45o from the bottom and lift up and out. 2) Turn off the gas supply to the unit.
MAINTENANCE DC SPARK BOX BATTERY REPLACEMENT 1) Remove the faceplate by lifting it up off the hinges on the sides of the firebox. 2) Remove the door frame overlay by swinging out 45o from the bottom and lift up and out. DC SPARK BOX REPLACEMENT 1) Remove the faceplate by lifting it up off the hinges on the sides of the firebox. 5) Disconnect the 2 DC spark generator wires from the DC Spark box located just behind the bracket tab as shown.
MAINTENANCE VALVE TRAY REPLACEMENT Warning: Turn off the unit by way of the wall switch or remote. Allow unit to cool at least 10 min. - prior to removing faceplate. 1) Turn the unit off and allow it to cool down to room temperature prior to handling. 5) Remove the glass door. a) Remove the 3 screws shown below at the bottom of the glass door. b) Swing the door out 45o from the bottom and lift up and out. 2) Turn off the gas supply to the unit.
MAINTENANCE 7) Remove bottom cover by undoing 3 screws securing it to the firebox base, lift up and out. 10) Unplug the Ignitor wire from the DC Sparker. Ignitor Wire Aerial View of the inside of the unit shown. 11) Remove the valve tray by undoing 12 screws. 8) Disconnect the ON/OFF connector wires from the valve. ON/OFF Connector Wires 9) Disconnect the DC Sparker leads at the valve. 12) Slightly lift out valve tray. 13) Disconnect the inlet gas line.
PARTS LIST MAIN ASSEMBLY Part # Description 9) 476-101 Burner Extenders 1) 910-074 2) 476-032 910-073 910-078 910-363 910-366 Spark Generator Switch c/w Wire DC Spark Mounting Bracket Spark Generator Battery Holder Battery AA White Wall Switch White Switch Plate Wire 904-658 370-055 476-023 476-055 521-035 Inlet Gas Flex Line SS Flue Collar Gasket Plate Relief Gasket Valve Tray Gasket Inner Flue Collar Gasket 3) 476-100 Bottom Cover NG/LP 940-359/P 476-011 Flush Glass Flush Glass 4) 476-530 5) 47
PARTS LIST ACCESSORIES Part # Description 30) 476-907 Reflective Stainless Steel Panels 31) 476-944 476-947 Faceplate & Door Frame Overlay - Black Faceplate & Door Frame Overlay - Stainless Steel 946-671 946-672 Cobalt Blue Glass Crystals Natural River Pebbles 476-540 Door frame w/ Glass 32) 476-532 Screen Assembly 30 32 31 Regency Gemfire™ Gas Fireplace 53
NOTES 54 Regency Gemfire™ Gas Fireplace
WARRANTY Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency® is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product.
Register your Regency® warranty online www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products. • Help assure you get the most out of your warranty. • Eliminate confusion and frustration if warranty** service is required in the future.