www.regency-fire.com P48 Gas Fireplace Owners & Installation Manual MODELS: P48-NG Natural Gas P48-LP Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fire or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life. Do not touch any electrical switch: do not use any phone in your FOR YOUR SAFETY building.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY. The P48 has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The model P48 has been approved by Warnock Hersey for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
TABLE OF CONTENTS Page Safety Label Safety Label ............................................................... 4 Installation Important Message .................................................... 5 Before You Start ........................................................ 5 General Safety Information ......................................... 5 Installation Checklist .................................................. 5 Manufactured Mobile Home Additional Requirements ......................................
This is a copy of the label that accompanies each P48-NG and P48-LP Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS The P48-NG/P48-LP Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes.
INSTALLATION This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label 51,000 (NG) Btu/h, 48,000 (LP) Btu/h) after burning appliance for 15 minutes. 2) If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize. CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Clearance to Combustibles from: Back Side Floor 0" 0" 0" (0mm) (0mm) (0mm) Caution Requirements The top, back and sides of the fireplace are defined by standoffs.
INSTALLATION MANTELS Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from louver are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a noncombustible board. This drawing is to scale at 1:6 (one inch = 6 inches) Mantel can be installed anywhere in shaded area using the above scale for units with the Flush Front and with the optional Bay Front.
INSTALLATION FRAMING & FINISHING 1) Determine the total thickness of facing material (eg. drywall plus ceramic tiles) to allow the finished surface to be flush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick. 2) Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is 47-1/2" high x 48-1/2" wide x 26-1/4" deep (1207mm H x 1232mm W x 667mm D). See Diagram 1.
INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position. Top Standoff Assembly The top standoffs are shipped in a flat position and must be folded into shape and attached. 1) Remove the standoffs from the fireplace top. 2) Take each standoff and bend into the correct shape.
Regency P48 Zero Clearance Direct Vent Gas Fireplace V E V M V B Vent terminal . F V V A G B C V A V B B V A K B H j N V Area where terminal is not permited A V 18" L A Note: - A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. - Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
INSTALLATION VENTING Regency Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P48 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 11. Regency Direct Vent (Flex) System Termination Kit (Part# 946-615) includes all the parts needed to install the P48 with a maximum run of 4 feet.
INSTALLATION SIMPSON DURA-VENT VENTING Horizontal or Vertical Terminations The Simpson Dura-Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized finish. We recommend using the galvanized finish for installation with the P48.
INSTALLATION VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and REGENCY DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45o and one 90o elbow (two 45o elbows equal one 90o elbow). Note: Must use optional flue adapter (Part # 370-994) when using Simpson Dura-Vent pipe. (Refer to page 13.
INSTALLATION Horizontal Venting with Two (2) 90o Elbows Horizontal Venting with Three (3) 90o Elbows One 90o elbow = Two 45o elbows. One 90o elbow = Two 45o elbows. Option A) B) C) D) E) F) 1' 2' 3' 4' 5' 6' V Min. Min. Min. Min. Min. Min. H + H1 3' Max. 4' Max. 5' Max. 6' Max. 7' Max. 8' Max. With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal. Please note minimum 1 foot between 90o elbows is required.
INSTALLATION Horizontal Venting with Three (3) 90o Elbows One 90o elbow = Two 45o elbows. Option A) B) C) D) E) F) V 2' Min. 3' Min. 4' Min. 5' Min. 6' Min. 7' Min. H 1' Max. 2' Max. 3' Max. 4' Max. 5 Max. 6' Max. V + V1 3' Min. 4' Min. 6' Min. 8' Min. 10' Min. 12' Min. H + H1 4' Max. 5' Max. 6' Max. 7' Max. 8' Max. 9' Max. With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal. Please note min. 1 foot between 90o elbows is required.
INSTALLATION Vertical Venting with Three (3) 90o Elbows One 90o elbow = Two 45o elbows. Option A) B) C) D) E) H 1' Max. 2' Max. 3' Max. 4' Max. 5' Max. V 1' Min. 2' Min. 3' Min.' 4' Min. 5' Min. H + H1 3' Max. 4' Max. 5' Max. 6' Max. 7' Max. V + V1 3' Min. 5' Min. 7' Min. 9' Min. 11' Min. With these options, max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 7 feet total horizontal. Please note min. 1 foot between 90o elbows is required.
INSTALLATION VENTING ARRANGEMENTS - VERTICAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (Propane & Natural Gas) The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations , using two 90o elbows, with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas. • • • Vent must be supported at offsets. Firestops are required at each floor level and whenever passing through a wall. Maintain clearances to combustibles.
INSTALLATION The P48 is approved for a maximum 40 ft. straight vertical, with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas, as per diagram. The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas. Maximum two 45o elbows allowed.
INSTALLATION HORIZONTAL INSTALLATIONS Install the vent system according to the manufacturer's instructions included with the components. 1) Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably on the right side of the unit and the electrical (junction block is on the left side) on the left.
INSTALLATION VERTICAL TERMINATION 1) Maintain the 1-1/4"(32mm) clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation. Check pages 16-17 for the maximum vertical rise of the venting system and the maximum horizontal offset limitations. Diagram 1 2) Set the gas appliance in its desired location.
INSTALLATION INSTALLATION PROCEDURES for Regency Direct Vent System (Flex) 1) Locate the unit in the framing, rough in the gas (preferably on the right side of the unit) and the electrical (Junction block is on the left side) on the left. Locate the centerline of the termination and mark wall accordingly. Cut a 11"(279mm) hole in the wall (inside dimension).
INSTALLATION P48-NG System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: #27 Max. Input Rating 51,000 Btu/h Min. Input Rating 29,000 Btu/h Supply Pressure min.5.0" w.c. Manifold Pressure (High) 3.8"+/- 0.2"w.c. Log Set: Ceramic fibre, 8 per set. Vent System: Simpson Dura-Vent Direct Vent System, Regency Flex Kit P48-LP System Data For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.
INSTALLATION BRICK PANELS INSTALLATION 1) Unhook the 2 spring loaded hooks from the bottom of the flush door and lift the Flush Front off the unit. 5) Place the top bracket onto the front edge of the top panel (refer to Diagram 5). 2) Unwrap the brick pattern panels from the protective wrapping. Top Bracket Note: The logs must not be in the unit. a) Loosen the two screws from the bottom of the baffle plate. Install the bottom clips onto the plate (refer to Diagram 1).
INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
INSTALLATION 6) Embers should be placed in front of Log 02-85 and Log 02-86. 8) Line up the hole on the underside of Log 02-84 with the pin on Log 02-86 and position the notch on the bottom of the log into the last grate post. 02-88 02-84 02-86 02-85 02-86 02-83 Embers Last Grate Post Pin in Log CAUTION: DO NOT cover burner ports with embers. 7) Place Log 02-83 onto the pin in Log 02-88 and position the notch on the bottom of the log into the 4th grate post.
INSTALLATION 10) Place Log 02-90 onto the right side of the grate. Position the cut-out on the underside of the log onto the grate bar. 11) Place Log 02-87 on the middle left side of the burner. Position the bottom rear of the log against the rear tab on the left side of the grate. Rest the front edge of the log in the notches on Log 02-85. 02-87 02-90 Tab Cut-out on the underside of the log. 02-85 02-90 02-83 02-88 02-89 02-87 02-84 02-85 Position the cut-out onto the grate bar.
INSTALLATION STANDARD FLUSH DOOR The standard flush door comes with a black frame. To install the frame, simply hook the top door flange onto the top of the unit and swing the door towards the unit, diagram 1. FLUSH LOUVERS 1) Install the top louver by sliding the two bracket clips into the brackets located underneath the top of the firebox. 2) Install the bottom louver by folding the louver down and then sliding the Bottom Louver bracket down onto the 2 pins on the base of the unit (diagram 1).
INSTALLATION OPTIONAL BAY DOOR 4) Reconnect the 2 spring hooks securing the flush door. BAY LOUVERS The Bay louvers MUST be used with the Bay glass option. 5) Slide the valve extension knobs onto the valve knobs. 1) Install top louver by sliding the two bracket clips into the brackets located on top of the bay door. See below. The fitted louver leaves a small gap between faceplate bottom and louver top. The optional Bay door is an overlay on the flush front.
INSTALLATION OPTIONAL FINISHING TRIM NOTE: Remove both the Flush Louvers or Bay Louvers and the Flush Front or Bay Front prior to installing the Finishing Trim. DOUBLE SCREEN DOOR 1) Pull out the top louver. 1) Install the Finishing Trim sides as shown in the diagram, line up the holes in the side trim with the holes in the firebox side. 2) Secure with 2 screws per side. 3) Loosen the 3 screws in the top inside edge of the firebox.
INSTALLATION OPTION 1: REMOTE CONTROL OPTION 2: WALL SWITCH OPTION 3: WALL THERMOSTAT Can be used with Option 2 or 3 but not both. Can be used with Option 1 or 3 but not both. Can be used with Option 1 or 2 but not both. Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty. 1) Run the supplied 15' of wire through the back gas inlet opening. Be careful not to damage wire.
INSTALLATION WIRING DIAGRAM Electrode Thermocouple #8 Ground Lug (for mobile home) ** However DO NOT leave this connection live until the fan is installed.** Gas Pilot Nut Star washer NOTE: Even if the fan is not purchased with the unit, it is still a good idea to hardwire the terminal block in case the fan is installed at a later date. (Do not cut the ground terminal off under any circumstances.) Thermopile No electrical power supply is required for the gas control to operate.
INSTALLATION INSTALLING THE OPTIONAL FAN 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualified electrician. The neutral (wider) slot of the polarized receptacle should be at the top. 9) Attach the two control boxes to the bottom louver and tighten the 2 screws on the left side and 2 screws on the right side. Unit must be grounded at all times.
INSTALLATION CONVERSION KIT FROM NATURAL GAS TO PROPANE MODEL #370-969 FOR P48 USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit Contains: Qty.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed. 5) Verify that the venting and cap are unobstructed. 6) Ensure that the brick panels are installed.
OPERATING INSTRUCTIONS NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance.
MAINTENANCE MAINTENANCE INSTRUCTIONS 2) Remove the Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material. 7) Drop the thermocouple or thermopile down through the extrusion and pull it out of the unit. 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year.
MAINTENANCE DOOR GLASS Your Regency fireplace is supplied with high temperature 5mm-Ceramic glass. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials. CAUTION & WARNINGS: Bay Glass Replacement 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Remove the nuts holding the glass clips in place and remove. 3) Replace the glass. The glass must have gasketing around it.
MAINTENANCE REMOVING VALVE 7) Remove the right and left side deflectors by removing the 2 screws on each deflector. 1) Shut off the gas supply. 2) Remove the louvers (and bay door if it has been installed). 3) Open the flush door and remove the door. 4) Remove the logs and side brick panels, if installed. Lift entire valve tray assembly out. 5) Remove the grate by lifting up and out. 11) Disconnect the 2 TP wires and the 2 TH wires from the valve.
PARTS LIST P48 MAIN ASSEMBLY Part # 1) 3) 4) 6) 7) 8) 9) 10) 948-259 948-046 948-115 430-129 910-429 910-428 910-430 904-687 Description Door Handle Chain Spring Receptacle Box Mount Box - Receptacle Duplex Receptacle Cover - Receptacle Clamp Connector 20) 370-037 21) 370-038 Top Nailing Strip Side Nailing Strip 22) 370-015 Baffle Plate 23) 780-011 24) 780-013 Standoff - Top Standoff - Side/Back 27) 28) 29) 30) Outer Flue Collar Inner Flue Collar Assy Flue Mounting Plate Gasket for Flue Collar *
PARTS LIST 30 28 89 50 93 30 94 20 93 29 27 21 23 92 22 91 95 96 23 102 100 99 97 24 21 98 90 HEAT WAVE DUCT KIT DOORS & LOUVERS PLEASE REFER SEPARATE SECTION 10 6 101 7 8 4 9 55 57 3 1 35 24 42 54 106 56 49 38 48 43 47 46 105 52 51 53 Regency P48 Zero Clearance Direct Vent Gas Fireplace HEAT RELEASE DUCT KIT 41
PARTS LIST P48 BURNER & LOG ASSEMBLY Part # Description 370-574/P 370-576/P * Valve Assembly - Natural Gas Valve Assembly - Propane Gasket - Valve Access Plate 56) 57) 910-190 910-378 910-380 Piezo Ignitor & Nut Valve S.I.T. - Natural Gas Valve S.I.T. - Propane 66) 67) 68) 69) 910-038 910-039 * W840470 904-662 904-434 936-170 Pilot Assy - S.I.T. - 3 Flame NG Pilot Assy - S.I.T. - 3 Flame LP Pilot Holder Pilot Assembly Gasket #27 Orifice - N.G.
PARTS LIST P48 FLUSH DOOR & LOUVERS Part # Description 370-925 370-924 370-926 133) * 134) * Flush Flush Flush Flush Flush Louvers (Set) - Steel/Black Louvers (Set) - Black Louvers (Set) - Gold/Black Louver Assembly - Top Louver Assembly - Bottom 370-518/P 135) 940-335/P 138) * 139) 936-155 Flush Door Assembly Complete Glass (Flush) Flush Door Frame Glass Gasket (Tadpole) 140) 948-042 Spring Hinge 370-944 370-946 141) * 142) * 143) * Finishing Trim - Black Finishing Trim - Steel Trim Side Left Tri
PARTS LIST P48 BAY FRONT & LOUVERS Part # 106) 107) 108) 111) 112) 370-931 370-932 Bay Front Complete with Glass & Black Trim Bay Front Screen & Black Trim 940-337/P 936-243 940-336/P 902-362 902-363 370-905 370-906 Side Glass Glass Gasket Center Glass Brick Panel - Left Side Bay Brick Panel - Right Side Bay Bay Brick Panel Set - Standard Brown Bay Brick Panel Set - Standard Red 113) 370-086 370-936 370-934 115) 116) 117) 119) 120) Description 370-938 370-942 370-940 * * 904-196 370-093 400-189 12
NOTES _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ ____________
NOTES _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ ____________
WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable.
Regency fireplace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product. See the inside back cover for details. Register your Regency online at http://www.regency-fire.