P33-4 Zero Clearance Direct Vent Gas Fireplace Owners & Installation Manual www.regency-fire.com MODELS: P33-NG4 Natural Gas P33-LP4 Propane WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your FOR YOUR SAFETY building.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The P33-4 has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The P33-4 has been approved by Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency® product has been tested and listed by Warnock Hersey/Intertek as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2002/CSA 2.33-2002 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN/CGA-2.17-M91.
TABLE OF CONTENTS SAFETY LABEL Safety Label...................................................................5 REQUIREMENTS Important Message ......................................................7 Before You Start ............................................................7 General Safety Information............................................7 Requirements ................................................................7 Optional Bay Door .....................................................
SAFETY LABEL SAFETY LABEL This is a copy of the label that accompanies each P33-4 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open. NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.
INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The P33-NG4 or P33-LP4 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturer's instructions and all applicable codes.
INSTALLATION INSTALLATION CHECKLIST 1) Locate appliance a) Room location (Refer to "Locating Your Fireplace" Section) b) Clearances to Combustibles (Refer to "Clearances" Section) c) Mantle Clearances (Refer to "Combustible Mantels" Section) d) Framing & Finishing Requirements (Refer to "Framing & Finishing" Section) e) Venting Requirements (Refer to "Venting" Sections) 2) Assemble Top Facing Support and Side Nailing Strips (Refer to "Unit Assembly Prior to Installation" Section).
INSTALLATION UNIT DIMENSIONS WITH CONTEMPORARY FACEPLATE UNIT DIMENSIONS 23"(584mm) 29"(737mm) 31-1/2"(800mm) 33"(838mm) 28-1/2"(724mm) 33"(838mm) 12-3/4"(324mm) Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace 9
INSTALLATION CLEARANCES FOR BAY OR FLUSH FRONT The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.
INSTALLATION COMBUSTIBLE MANTELS Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board. This drawing is to scale at 1:6 (one inch = 6 inches). Mantel can be installed anywhere in shaded area or higher using the above scale.
INSTALLATION MANTEL LEG CLEARANCES WITH FLUSH OR BAY GLASS Combustible mantel leg clearances from side of unit as per diagram: Maximum 1-1/2" projection at 2" minimum clearance.
INSTALLATION FRAMING AND FINISHING 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the finished surface to be flush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick. Rigid Vent Minimum Clearances Rear Termination For Rigid Vent Top Header Install Side Nailing Strips, and Top Facing Support before unit is slipped into position. See "Unit Assembly Prior to Installation" Section 10" (254mm) dia.
INSTALLATION FRAMING DIMENSIONS WITH CONTEMPORARY FACEPLATE M I Top Header Wood, drywall or other facing. 10" (254mm) dia. Hole through wall Vent. H I G J NOTE: If this is an outside corner, the minimum distance between the vent and the outside corner is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Rigid Vent termination cap.
INSTALLATION FRAMING & FINISHING WITH CONTEMPORARY FACEPLATE 1) Determine the total thickness of facing material (e.g. drywall, wood plus ceramic tiles) to allow the finished surface to be flush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick. NOTE: Facing material may not protrude beyond unit, otherwise the tional accesories will not be able to be mounted to the unit.
INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly positioned and attached to the top before the unit is put into position. Top Standoff Assembly The top standoffs are shipped in a flat position and must be pulled up and bent into the correct shape. 1) Remove the standoffs from on top of the firebox by undoing the screws. 2) Take each standoff and bend into the correct shape.
INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS Minimum Clearance Requirements Canada1 USA2 A Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) B Clearance to window or door that may be opened 12"(30cm) 9" (23cm) C Clearance to permanently closed window * * D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) from the center line of the terminal (check with the local code) 18"(46cm) 18"(46cm) E Clea
INSTALLATION REGENCY® DIRECT VENT FLEX SYSTEM Horizontal Terminations Only This venting system, in combination with the P33-4 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey/ Intertek. The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" Section . Regency® Direct Vent Flex Termination Kit (Part # 946-513) includes all the parts needed to install the P33-4 with a maximum run of 2 feet.
INSTALLATION INSTALLATION PROCEDURES for Regency® Direct Vent System (Flex) *If this is an outside corner, the minimum distance between the vent and the outside corner is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Dura-Vent termination cap. See "F" in the diagram in "Exterior Vent Trmination Locations" Section. 1) Locate the unit in the framing, rough in the gas (preferably on the right side of the unit) and the electrical (Junction block is on the left side) on the left.
INSTALLATION RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations The minimum components required for a basic horizontal termination are: 1 1 1 1 1 AstroCap Horizontal Termination Cap 45o Elbow Rigid Pipe Adaptor Wall Thimble Length of pipe to suit wall thickness (see chart) For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding.
INSTALLATION 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. 4” X 6- 5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency.
INSTALLATION Description Simpson Selkirk Direct Vent Pro® Direct Temp™ American Metal Products® Metal-Fab™ Security ICC Excel Sure Seal Secure- Vent® Direct Amerivent Direct Attic Insulation Shield 12” 46DVA-IS N/A@ FPI N/A 4DAIS12 N/A SV4RSA N/A Attic Insulation Shield - Cold Climates 36” N/A N/A 4DAIS12 N/A N/A TM-4AS Basic Horizontal Termination Kit (A) Disc.
INSTALLATION RIGID PIPE VENTING ARRANGEMENTS Vertical Terminations (Propane & Natural Gas) The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using one 90o elbow, with rigid pipe vent systems for Propane and Natural Gas. • • • • Vent must be supported at offsets. Firestops are required at each floor level and whenever passing through a wall. Maintain clearances to combustibles. When using Contemporary Faceplate, unit must be raised 1".
INSTALLATION The P33-4 is approved for a maximum 40 ft. straight vertical, with rigid pipe vent systems for Propane and Natural Gas. The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas. Maximum two 45o elbows allowed. • Vent must be supported at offsets. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles.
INSTALLATION RIGID PIPE VENTING ARRANGEMENTS Horizontal Terminations REGENCY® DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45o and one 90o elbow (two 45o elbows equal one 90o elbow). Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems.
INSTALLATION Horizontal Venting with Three (3) 90o Elbows Horizontal Venting with Two (2) 90o Elbows One 90o elbow = Two 45o elbows. Option V H + H1 A) 1' Min. 3' Max. B) 2' Min. 4' Max. C) 3' Min. 5' Max. D) 4' Min. 6' Max. E) 5' Min. 7' Max. F) 6' Min. 8' Max. One 90o elbow = Two 45o elbows. With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal. Option H V H+H1+H2 A) 1' Max. 1' Min. 3' Max.
INSTALLATION Horizontal Venting with Three (3) 90o Elbows One 90o elbow = Two 45o elbows. Option V H V+V1 H+H1 A) 2' Min. 1' Max. 3' Min. 4' Max. B) 3' Min. 2' Max. 4' Min. 5' Max. C) 4' Min. 3' Max. 6' Min. 6' Max. D) 5' Min. 4' Max. 8' Min. 7' Max. E) 6' Min. 5' Max. 10' Min. 8' Max. F) 7' Min. 6' Max. 12' Min. 9' Max. With these options, maximum total pipe length is 30 feet with minimum of 12 feet total vertical and maximum 9 feet total horizontal.
INSTALLATION Vertical Venting with Three (3) 90o Elbows One 90o elbow = Two 45o elbows. Option A) B) C) D) E) H 1' Max. 2' Max. 3' Max. 4' Max. 5' Max. V 1' Min. 2' Min. 3' Min.' 4' Min. 5' Min. H + H1 3' Max. 4' Max. 5' Max. 6' Max. 7' Max. V + V1 3' Min. 5' Min. 7' Min. 9' Min. 11' Min. With these options, max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 7 feet total horizontal. Please note min. 1 foot between 90 o elbows is required.
INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM Masonry chimneys may take various contours which the flexible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending. THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. The Air Intake pipe must be attached to the inlet air collar of the termination cap.
INSTALLATION VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces 30' (9.1m) Max. 8' (2.4m) Min. 30” (762mm) 2’ (51mm) max. Vertical Height (feet) 30 Horizontal Distance (Feet) When using Contemporary Faceplate, unit must be raised 1". The shaded area in the diagrams show the allowable vertical terminations.
INSTALLATION UNIT INSTALLATION WITH HORIZONTAL TERMINATION Install the vent system according to the manufacturer's instructions included with the components. b) Horizontal runs of vent must be supported every three feet. Wall straps are available for this purpose. 1) Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit.
INSTALLATION 8) Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1-1/4 inches. Secure the connection between the vent pipe and the vent cap 3 sheet metal screws. 4) Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed.
INSTALLATION PILOT ADJUSTMENT Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile, 1 around the thermocouple and 1 flowing across the burner (it does not have to be touching the burner). Note: If you have an incorrect flame pattern, contact your FPI dealer for further instructions. P33-NG4 System Data With Flush or Bay Glass: For 0 to 2000 feet altitude Burner Inlet Orifice Sizes: #44 Max. Input Rating 22,500 Btu/h Min.
INSTALLATION CONVERSION KIT# 434-969 FROM NG TO LP For P33-4 Using SIT 820 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! NOTE: See page 1 for H25 / H27 conversion instructions and page 7 for E33S / U32S conversion instructions. d) Remove the 2 screws holding the Burner Assembly to the firebox base. Push the Burner Assembly to the left and lift out. Each Kit contains one LPG Conversion Kit and one DC Sparker Kit.
INSTALLATION 7) Turn control knob to the “OFF” position. 8) Remove the black protection cap by hand from the high-low knob (Fig.1). 12) Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten. 15) See Page 35 for DC Sparker installation. 16) Attach the label "This unit has been converted to LPG" near or on top of the serial # decal. 17) Replace yellow "NG" label with red "LPG" label. 18) Check for gas leaks. 19) Check inlet and outlet pressures.
INSTALLATION Installation of the DC Sparker 1) 11) Install the supplied battery into the DC Sparker Box by opening the battery compartment. Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit. Locate the Piezo Ignitor situated at the side of valve. Piezo Ignitor 2) 6) Remove the Piezo Ignitor by unscrewing the nut at the back of the mounting bracket. NOTE: The battery in the DC Sparker Box will need to be replaced annually.
INSTALLATION OPTIONAL BRICK PANELS 1) Undo the bottom 2 door latches and open and remove glass door. Remove logs. 2) Attach the 2 Rear Brick Retaining clips to the rear wall. Loosen the screws in the top and rear wall of the firebox and slide the retaining clips into position (tight against the firebox top) and then tighten the screws. LOG SET INSTALLATION D) 251 A) 250 Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced.
INSTALLATION 8) Pull off ember size pieces of rock wool and gently place them on the front of the burner tray in the places shown in the photo below. Do not compress the rock wool, leave it loose. 25 3 250 Separate platinum embers and place them on the front of the burner on and around the rock wool. 254 6) Place the bottom left front edge of Log 251 against the left edge of the burner tray and rest the log on the cutout on Log 253.
INSTALLATION DOUBLE SCREEN DOOR FLUSH LOUVERS 1) Install the top louver by sliding the two bracket clips into the brackets located underneath the top of the firebox. 2) Install the bottom louver by folding the louver down and then sliding the Bottom Louver bracket down onto the 2 pins on the base of the unit (Diagram1). Secure with 1 screw (Diagram 2). Diagram 1 1) Pull out the top louver. 2) Center the screen door and hook over the flush door.
INSTALLATION BAY LOUVERS 1) Remove flush louver top heat shield by removing the 4 screws. 4) Install bottom louver by sliding the two bracket clips into the brackets located underneath the bay door. Secure with 1 screw into each Bottom Louver Mounting Bracket as per diagram below. Use the bottom hole in the bracket. 5) Slide the valve extension knobs onto the valve knobs. Match the correct ext. knob with the valve knob.
INSTALLATION FULL SCREEN DOORS 1) Before beginning the installation, remove the Glass Door from the unit. Refer to the manual for instructions. 2) Slide the Bottom Faceplate Bracket into the bottom of the unit, secure it into the pins located on the inside of the fire box. Once the bracket is in place, tighten the screws into the hinges on the left and right sides.
INSTALLATION NOTE: Should the finished wall protrude beyond the face of the unit, you can accommodate up to 1/2" depth. Simply push in the Full Screen Door Frame until it aligns against the finished wall. Secure Top Flange of Full Screen Door Frame as described in step 4 b). 8) Re-install Glass Door. Refer to the manual for instructions. 9) Slide the Top Grill into the louver brackets located on the inside top of the firebox. Push in place.
INSTALLATION CONTEMPORARY FACEPLATE INSTALLATION PART 1 (DERATING TO LOWER BTU RATING) THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 1) Shut off the gas supply. Contemporary Faceplate Derating Kit Contains: Qty. Part # Description 2) a) Open the flush door and remove the door (see p.37 in the P33-4 manual). 1 904-434 Burner Orifice #47 (Natural Gas) 1 904-241 Burner Orifice #56 (Propane Gas) b) Remove the logs, embers, and brick panels (if used).
INSTALLATION CONTEMPORARY FACEPLATE INSTALLATION PART 2 CONTROL MOUNTING PLATE INSTALLATION (FOR P33-4 UNIT WITH FACEPLATE ONLY) 1) Remove top and bottom louvers. 2) Remove ON/OFF switch (for P33-4) from the bottom louver. 3) Attach ON/OFF switch to control mounting plate with one screw as shown below. Diagram 1 5) Slide the thermodisc/cover assembly into the bracket clip on the underside of the firebox. Check that no wire will touch the hot surfaces. Diagram 2.
INSTALLATION CONTEMPORARY FACEPLATE INSTALLATION PART 3 3) Loosen 4 phillips head screws located inside firebox, for screw locations see Diagram 4. Install mounting frame and retighten screws.
INSTALLATION 6) Hook the flange on the faceplate over the top of the flush door and gently lower the faceplate into place until it rests against the faceplate supports as shown in Diagrams 7 & 8.
INSTALLATION Optional REMOTE CONTROL Use the Regency® Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate. 1) Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location. Use Thermostat Wire Table.
INSTALLATION WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation. (Do not cut the ground terminal off under any circumstances.
INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
INSTALLATION INSTALLING THE OPTIONAL FAN 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualified electrician. The 12) Secure the fan wires and power cord by neutral (wider) slot of the polarized receptacle attaching one of the adhesive backed should be at the top. wire holder clips (Part #910-199) onto Unit must be grounded at all times.
OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS OFF a Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace 51
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. control knob. 4) When the pilot stays lit, turn the gas knob further counterclockwise to the "ON" position. 5) Use the wall switch, thermostat or remote control to turn on the unit. 6) Rotate the flame height regulator to adjust the flame height higher or lower.
MAINTENANCE NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance. Blower: Regency® gas appliances use high tech blowers to push heated air farther into the room.
MAINTENANCE THERMOPILE/ THERMOCOUPLE 1) Open the bottom louvers. 2) Loosen the thermocouple or thermopile with a 7/16" wrench. 3) Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Disconnect thermopile by loosening 2 screws marked TP on the valve. 4) Drop the thermocouple or thermopile down from the bracket and pull it out of the unit. Bay Glass Replacement Remove the flush door front. Remove the 4 glass clips from each corner. Slide in the new replacement glass.
MAINTENANCE REMOVING VALVE INSTALLING VALVE 1) Shut off the gas supply. 1) Attach the valve to the valve bracket with the 4 (m5x8 metric) screws provided. 2) Remove the louvers (and bay door if it is on). 2) Reconnect the "gas out" flare fitting with an 11/16" wrench. 3) Open the flush door and remove the door. 4) Remove the logs. 3) Reconnect the "gas out" flare nut with a 13/16" wrench.
PARTS LIST MAIN ASSEMBLY Part # 56 Description 1) 948-247 2) * Door Handle Thermodisc Bracket 7) 910-428 8) 910-429 9) 910-430 10) 904-687 13) 948-045 14) 948-115 Duplex Receptacle Box - Receptacle Cover - Receptacle Clamp Connector #12 Jack Chain Door Extension Spring 16) * 17) * 19) 430-129 Thermodisc Top Thermodisc Box Base Receptacle Box Mount 20) 430-031 22) 433-017 23) 433-011F 24) 511-044 790-091 26) * 27) * 28) * 30) * 31) * Top Nailing Strip Firebox Baffle Top Standoff Standoff - Side Sta
PARTS LIST HEAT WAVE DUCT KIT 89 93 94 93 95 92 91 30 96 31 28 30 27 102 100 20 99 97 23 98 90 23 26 22 10 19 14 8 7 37 104 2 9 13 1 36 38 35 34 16 49 17 33 63 43 ON-OFF SWITCH 47 ASSEMBLY BRICK PANEL SET 46 42 50 FAN SWITCH ASSEMBLY DOORS & LOUVERS PLEASE REFER SEPARATE SECTION Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace 57
PARTS LIST BURNER & LOG ASSEMBLY Part Description 53) 430-055 54) 910-421 55) 910-422 56) 910-190 Gasket - Valve Access Plate - NG/LP Pilot ON/OFF Extension Knob Flame HI/LOW Extension Knob Piezo Ignitor and Nut 433-574/P 433-576/P 57) 910-478 58) * 59) * 60) * 66) 910-038 910-039 904-568 904-163 936-170 67) * 68) W840470 79) 433-525 82) 433-024 83) * 85) 431-930 86) 430-097 87) 433-018 Valve Assy - Natural Gas Valve Assy - Propane S.I.T.
PARTS LIST FLUSH FRONT & LOUVERS Part # Description 117) 904-196 131) 430-947 Magnet - 1' round Flush Glass Trim (set) - Brushed Steel (Option) 430-918 430-922 430-923 133) * 430-162 134) * Flush Louvers (set) - Gold/Black (Option) Flush Louvers (set) - Black (Option) Flush Louvers (set) - Black/Steel (Option) Flush Louver Assy-Top Front Deflector Flush Louver Assy-Bottom 135) 137) 139) 140) 433-538 940-088/P 904-691 936-155 948-042 Flush Door Assembly Complete Glass (Flush) U-Clip Glass Gasket (Tad
PARTS LIST CONTEMPORARY FACEPLATE Part # 1) Description 434-516 434-516BL 434-516R 434-517 Faceplate Assembly Black Faceplate Assembly Painted Blue Faceplate Assembly Painted Red Faceplate Assembly Stainless Steel 2) 434-033 Mounting Plate 3) 434-514 909-924 904-925 Faceplate Support Bracket Assembly Bumper Rubber W/Machine Screw 8-32 x 3/8" Cap Assy Brushed Stainless 3/4" diameter.
NOTES Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace 61
NOTES 62 Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace
ireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspec before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original pu roduct. This warranty is not transferable.
Register your Regency® warranty online www.regency-fire.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.