Installation manual

4
Regency Horizon™ HZO42 Gas Fireplace
SAFETY LABEL
This is a copy of the label that accompanies each
HZO42 Outdoor Fireplace. We have printed a copy
of the contents here for your review.
NOTE: Regency
®
units are constantly being
improved. Check the label on the unit and if there is
a difference, the label on the unit is the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation and
repair must be done by a plumber or gas fi tter
licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connec-
tors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle
type valve.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
364
364
FPI Fireplace Products International Ltd.
6988 Venture St.
Delta, BC, Canada V4G 1H4
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Serial No./ No de serie
Listed:
Certified for/Certifi e pour:
Tested to:
OUTDOOR GAS FIREPLACE /
CANADA and U.S.A.
FOYER À GAZ EXTÉRIEUR
IAS 4-96 (US) / CGA CR97-003 (CAN)
4001172
é
CAN/CGA-2.17-M91 /
.
NOT FOR USE WITH SOLID FUELS. /
NE PAS UTILISER AVEC DES COMBUSTIBLES SOLIDE.
Made in Canada/ Fabrique au Canada
Duplicate S/N
ÉÉ
é
QUIP A L'UISINE POUR GAZ PROPANE
CONCU POUR ETRE POELE: Mod le HZO42
PROPANE GAS: Model HZO42-LP
Minimum supply pressure
Manifold pressure high
Orifice size
Maximum input
Altitude
Maximum supply pressure
NATURAL GAS: Model HZO42-NG
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Grandeur de l'injecteur
D bit maximum selon
l'altitude
Pression d'allimentation maximum
Calorifique
ééé
é
14” WC/C.E. (3.49 kPa)
5" WC/C.E. (1.25 kPa)
WC/C.E.
44,500 Btu/h (13.04 kW)
3.5" (0.87 kPa)
#29 DMS
0-4500 ft/pi (0-1372 m)
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Grandeur de l'injecteur
D bit maximum selon
l'altitude
Pression d'allimentation maximum
Calorifique
ééé
é
14" WC/C.E. (3.49 kPa)
11” WC/C.E. (2.74 kPa)
WC/C.E.
43,500 Btu/h (12.74 kW)
10" (2.49 kPa)
#47 DMS
0-4500 ft/pi (0-1372 m)
Minimum supply pressure
Manifold pressure high
Orifice size
Maximum input
Altitude
Maximum supply pressure
D
E
F
A
B
C
Side Walls
A 11” (279mm)
B 36” (914mm)
C 18”(457mm)
D 12” (305mm)
E 57" (1448mm)
F 36" (914mm)
Ceiling
Min. Mantel Height
Max. Mantel Depth
Alcove Width
Alcove Depth
The installation must conform with local codes or, in the absence of local codes, with The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the Canadian Electrical Code, CSA C22.1 or with the National Electrical Code, ANSI/NFPA 70.
This appliance is onlyfor use with the type of gas indicated onthe rating plate . See owner's manual for details.
L'installation doit être conforme aux codes locaux ou, en l'absence de codes locaux,avec CAN/CSA-B149.1, gaz naturel et du propane ou du Code d'installation au ANSI Z223.1/NFPA 54. L'appareil, une fois installé, doit être connecté électriquement à la terre conformément aux codes locaux ou, en
l'absence decodes locaux,avec le Code canadien de l'électricité, CSA C22.1 ou avec le NationalElectrical Code,ANSI / NFPA70.
Cet appareil est àutiliser uniquement avec le type de gaz indiqué surla plaque signalétique. Voir le manuel dupropriétaire pour les détails.
CAN/CSA-B149.1, Natural Gas and Propane Installation Code or ANSI Z223.1/NFPA 54.
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le HZO42é
FOR OUTDOOR USE ONLY / POUR USAGE EXTÉRIEUR SEULEMENT
918-888b
HZO42-LPHZO42-NG