Installation manual

14
U32SE-5 FPI Direct Vent Gas Insert
INSTALLATION
16) Unscrew the pilot orifi ce with the Allen
key and replace with the LPG pilot orifi ce
in the kit and replace pilot cap.
17) Remove burner orifi ce with a 1/2"
wrench and discard. Use another
wrench to hold on to the elbow behind
the orifi ce.
Burner Orifi ce
18) Reinstall new burner orifi ce LPG
stamped #54 or LPG Orifi ce #56 for use
with Faceplate (orifi ce supplied with
faceplate) and tighten.
For both U32SE & P33E-4 units:
19) Remove regulator and discard. Install
the Hi/Lo pressure regulator onto the
valve with 2 screws as shown below.
20) Attach the label “This unit has been
converted to LPG” near or on top of the
serial # decal.
21) Replace yellow “NG” label with red
“LPG” label.
22) Reverse step 3 - 1
23) Check for gas leaks.
24) Check inlet and outlet pressures.
15) Undo clip and remove pilot cap to
expose pilot orifi ce.
ClipPilot Cap
Warning for P33E unit
Must install LPG Orifi ce #54 for use
with Flush, Louver, or Bay Door.
Must install LPG Orifi ce #56 for use
with Faceplate.
Remove the 2 screws, push Burner
Assembly to the left and lift out.
For the P33E unit only:
14) Remove the 2 screws holding the Burner
Assembly to the fi rebox base. Push the
Burner Assembly to the left and lift out.
9) Pull off the pilot cap to expose the pilot
orifi ce.
10) Unscrew the pilot orifi ce with the
supplied allen key and replace it with the
LP pilot orifi ce and re-install the pilot cap
and the pilot shield.
11) Re-install base cover.
12) Re-install the burner.
NOTE: Before re-installing the burner,
ensure the LP areation setting is set
at 1/2" min. when using glass crystals
and 1/8" min. when using ceramic
stones.
13) Follow steps 19 - 26 on this page.
Pilot Cap
Installer Notice:
These instructions must be
left with the appliance.