Installation manual

32
U32SE-5 FPI Direct Vent Gas Insert
32
OPERATING INSTRUCTIONS
During the rst few res, a white lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the lm will bake on and
become very dif cult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
OPERATING
INSTRUCTIONS
Before operating this appliance, proceed through
the following check list.
1) Read and understand these Instructions before
operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass door is in place. Never
operate the appliance with the door glass
removed.
5) Verify that all venting and the cap is
unobstructed.
6) Verify log placement. If the pilot cannot be seen
when lighting the unit - the logs or the embers
have been incorrectly positioned.
7) The unit should never be turned off and on
again without a minimum of a 60 second wait.
8) When lighting the appliance, the inside of the
glass may fog up. This will burn off after a few
minutes of operation.
DO NOT BURN THE APPLIANCE WITH
THE GLASS ASSEMBLY REMOVED.
FIRST FIRE
The rst re in your insert is part of the paint curing
process. To ensure that the paint is properly cured,
it is recommended that you burn your replace
for at least four (4) hours the rst time you use
it with the fan on. When rst operated, the unit
will release an odour caused by the curing of the
paint, the burning off of any oils remaining from
manufacturing. Smoke detectors in the house may
go off at this time. Open a few windows to ventilate
the room for a couple of hours.
The glass panel may require cleaning
after the unit has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
Note: When the glass is cold and the appliance
is lit, it may cause condensation and fog
the glass. This condensation is normal
and will disappear in a few minutes as
the glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
1) Press and release on ON/OFF button once
on the remote control or ON/OFF switch.
2) After approximately 4 seconds the spark
ignition system will spark for 60 seconds to
light the main burner.
3) The unit will turn on.
Note: The rst try for ignition will last approxi-
mately 60 seconds. If there is no ame ignition
(recti cation) the board will stop sparking for
approximately 35 seconds. After wait time ,
the board will start second try for ignition by
sparking for approximately 60 seconds . If
there is still no positive ignition the board will
go into lock out.
The system will need to be reset as follows:
a) Turn the system off using ON/OFF switch or
press ON/OFF button - if using optional remote.
b) After approximately 2 seconds turn on ON/
OFF switch or press ON/OFF button if using
optional remote.
c) Repeat step 2.
SHUTDOWN
PROCEDURE
1) Turn the wall mounted switch or remote to the
"OFF" position.
2) Press "OFF" on the remote control.
3) Turn the gas control knob to the "OFF" position
to turn off the pilot.
LIGHTING
PROCEDURE
IMPORTANT
To ignite or reignite the pilot, you
must rst remove the glass door.