Installation manual

U32SE-5 FPI Direct Vent Gas Insert
39
MAINTENANCE
VALVE ASSEMBLY REPLACEMENT
1) Turn the unit off and allow it to cool down to room temperature.
2) Turn off the gas supply to the insert.
3) Open the bottom louver.
4) Remove the door frame by lifting out from the bottom and lift up off
the glass door.
5) Remove the glass door.
a) Remove the 2 hooks shown below at the bottom of the glass
door.
b) Swing the door out 45
o
from the bottom and lift up and
out.
6) Remove the burner by undoing the 2 screws shown. Carefully slide
the burner to the left. Then lift the burner up and out ensuring not to
spill glass crystals.
7) Carefully set aside the burner and glass crystals.
Door Frame
Glass Door
Burner
EV1
EV2
Ground
8) Remove the base cover by lifting up from the back and maneover
out.
Base Cover
9) Disconnect the EV1, EV2, and ground wires from the valve - as
shown below.