Zero Clearance Room Sealed Gas Fireplace Manual Owners & Installation LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AS4553-2000, NZS 5262 and have been certified by the Australian Gas Association for installation and operation as described in these Installation and Operating Instructions. Your unit should be serviced annually by an authorised service person.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY. The P121/P121LC/P121RC/ P131 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The model P121/P121LC/P121RC/P131 has been approved by the Australian Gas Association for both safety and efficiency.
TABLE OF CONTENTS Safety Label Safety Label ............................................................... 4 Installation Important Message .................................................... 5 Before You Start ........................................................ 5 General Safety Information ......................................... 5 Installation Checklist .................................................. 5 Specifications ............................................................
SAFETY LABEL This is a copy of the label that accompanies each REGENCY P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open. 4 NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS The Regency P121/P121LC/P121RC/P131-NG or P121/P121LC/P121RC/P131-LPG Room Sealed Gas Fireplace must be installed in accordance AG601 and NZS 5261 and with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation.
INSTALLATION SPECIFICATIONS P121 - See Thru Note: These units are non-load bearing.
INSTALLATION P121LC - Left Corner Unit Note: These units are non-load bearing.
INSTALLATION LOCATING YOUR GAS FIREPLACE 1) When selecting a location for your stove, ensure that the clearances are met as outlined on page 9. A) P121 - See Thru 2) Provide adequate clearances for servicing. 3) The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete). This may be the floor, or raised up on a platform to enhance its visual impact.
INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated (refer to diagrams on page 8): Clearance to Combustibles from: Back 0" (0mm) Side 0" (0mm) Floor 0" (0mm) WARNING: Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and flue system be installed only in accordance with these instructions.
INSTALLATION FRAMING AND FINISHING 1) For ease of installation, frame your fireplace after it is positioned and the flue system is installed. Remember to install the top standoffs. See page 11 for assembly. Use 2x4's and frame to local building codes. CAUTION: Verify your fireplace dimensions, framing methods and finished wall facing details before framing. Determine the total thickness of facing material - drywall plus ceramic tiles, slate, etc.
INSTALLATION FACING & FINISHING REQUIREMENTS This fireplace is supplied with a 3" metal extension trim above the fireplace. The extension trim may be replaced if the framing is faced with a noncombustible material placed flush with the front and side face of the unit and extending from the top of the unit. (ie. tile, slate, etc.) UNIT ASSEMBLY PRIOR TO INSTALLATION The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position.
INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced flue terminals or the flue terminals of outdoor appliances according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand) a b c d e f g h j k Minimum Clearance (mm) Below eaves, balconies or other projections: - Appliances up to 50 MJ/h input 300 - Appliances over 50 MJ/h input 500 From the ground or above a balcony 300 From a return wall or external corner 500 From a gas meter (M) 1000 From an ele
INSTALLATION FLUEING ARRANGEMENT - HORIZONTAL TERMINATIONS Regency Direct Vent System (Flex) Horizontal Terminations Only These flueing systems, in combination with the P121/P121LC/P121RC/P131 Direct Vent Gas Fireplace, have been tested and listed as a direct flue heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 12.
INSTALLATION SIMPSON DURA-VENT FLUEING Horizontal or Vertical Terminations The Simpson Dura-Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized finish. We recommend using the galvanized finish for installation with the P121/ P121LC/P121RC/P131.
INSTALLATION FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (LPG & NG) The diagram below shows examples of horizontal termination arrangements using one, two, or three 90o elbows (two 45o elbows equal one 90o elbow). Note: 1) A maximum of three 90o elbows are permitted. 2) Minimum distance between elbows is 1 ft. (305mm). Simpson Dura-Vent 4" inner diameter 6-5/8" outer diameter Maintain clearances to combustibles as listed on page 9.
INSTALLATION Horizontal Flueing with Two (2) 90o Elbows Option A) B) C) D) E) F) 1' 2' 3' 4' 5' 6' V (305mm) Minimum (610mm) Minimum (914mm) Minimum (1.22m) Minimum (1.5m) Minimum (1.86m) Minimum H + H1 2' (610mm) Maximum 5' (1.5m) Maximum 8' (2.4m) Maximum 11' (3.35m) Maximum 14' (4.27m) Maximum 15' (4.5m) Maximum With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 15 feet total horizontal.
INSTALLATION FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (LPG & NG) Flue must be supported at offsets Maintain clearances to combustibles as listed on page 9. Firestops are required at each floor level and whenever passing through a wall. Must use optional flue adapter when using Simpson Dura-Vent pipe (Part# 510-994). The P121/P121LC/P121RC/P131 is approved for a maximum 35 ft. (10.
INSTALLATION Vertical Flueing with Two (2) 90o Elbows Option A) B) C) D) E) F) 1' 2' 3' 4' 5' 6' V (305mm) Minimum (610mm) Minimum (914mm) Minimum (1.22m) Minimum (1.5m) Minimum (1.86m) Minimum Vertical Flueing with Two (2) 90o Elbows H 4' (1.22m) Maximum 6' (1.86m) Maximum 9' (2.7m) Maximum 12' (3.6m) Maximum 15' (4.5m) Maximum 17' (5.1m) Maximum Option A) B) C) D) With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal.
INSTALLATION Vertical Flueing with Three (3) 90o Elbows Option A) B) C) D) 2' 3' 4' 5' V + V1 (610mm) Minimum (914mm) Minimum (1.22m) Minimum (1.5m) Minimum H + H1 3' (914mm) Maximum 6' (1.86m) Maximum 9' (2.7m) Maximum 12' (3.6m) Maximum With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal. Please note minimum 1 foot between 90o elbows is required.
INSTALLATION VERTICAL TERMINATION Diagram 3 to ensure that the termination is not recessed into the siding. 7) Before connecting the horizontal run of flue pipe to the flue termination, slide the Wall Thimble (Part # 942) over the flue pipe. 8) Slide the appliance and flue assembly towards the wall carefully inserting the flue pipe into the flue cap assembly. It is important that the flue pipe extends into the flue cap sufficient distance so as to result in a minimum pipe overlap of 1-1/4 inches.
INSTALLATION roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the flue height may solve the problem. 7) Ensure flue is vertical and secure the base of the flashing to the roof with roofing rails, slide storm collar over the pipe section and seal with a mastic. 8) Install the vertical termination cap by twistlocking it.
INSTALLATION CONVERSION KIT FROM NG TO LPG MODEL #730-969 FOR P121/P121LC/P121RC/P131 USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A AUTHORIZED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit Contains: Qty. Part # 1 910-018 1 1 1 1 1 910-037 * 908-255 908-529 918-032 Description SIT Conversion Kit-50% Turndown LPG LPG Injector (Pilot Orifice) Burner Orifice #50 Decal "Converted to LPG" 5/32" Allen Key Instruction Sheet 1) Remove the louvers and trim kit.
INSTALLATION P121/P121LC/P121RC/P131-NG System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: #31 Pilot Orifice NG Max. Input Rating 42 mj. Min. Input Rating 22 mj. Important: Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open flame for leak testing. PILOT ADJUSTMENT Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.
INSTALLATION LOG INSTALLATION 1) Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position. Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. 2) Place Log 326 on the front right side of the burner. Ensure that the notches on the far right side of the log fit into the grate posts.
INSTALLATION Repeat step 3 on the opposite side of the burner. Repeat step 5 on the opposite side of the burner. 329 327 327 329 4) Embers should be placed in front of Log 326 and Log 327 and also down the middle between the logs as shown in the image below. 6) Place Log 328 on the middle right side of the burner. Ensure that the log fits over the 2nd grate post from the right. 328 Caution: Do NOT cover burner ports. 5) Place Log 329 on the middle left side of the burner.
INSTALLATION GLASS DOOR REMOVAL 1) Remove the 8 screws that secure the glass door. FINISHING TRIM LOUVERS & GRILLS 1) Slide the Side Finishing Trim up into the slot in the top flange of the fireplace. Push tight against the magnet at the base of the unit. 1) Attach the screws provided to the top left and right corners. NOTE: Do not tighten the screw entirely, ensure that some room is left to be able to hang the grill or louver over the screw. Slide Trim into slot.
INSTALLATION Option 1: REMOTE CONTROL Option 2: WALL SWITCH Option 3: WALL THERMOSTAT Can be used with Option 2 or 3 but not both. Can be used with Option 1 or 3 but not both. Can be used with Option 1 or 2 but not both. Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty. 1) Run the supplied 4.5m of wire through the back gas inlet opening. Be careful not to damage wire.
INSTALLATION WIRING DIAGRAM No electrical power supply is required for the gas control to operate. ON-OFF SWITCH (910-138) BLACK Lockwasher Star washer #8 Ground Lug FAN 2 FAN 1 TERMINAL BLOCK FROM POWER LIVE POWER NEUTRAL Pilot Assembly Ground Wire 1 WHITE GROUND Gas Pilot 910-610 BLACK 910-802 BLACK ~ Thermopile Electrode Thermocouple ~ (for mobile home) Nut Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. SHUTDOWN PROCEDURE 1) Turn OFF the flame switch. 2) Push in gas control knob slightly and turn to "OFF" position. 3) Check to ensure there are no gas leaks. 4) Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed.
OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN1-B149/ANSI Z 223.1 (Australia: AS5601-2004, New Zealand: NZS 5261) WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
MAINTENANCE 2) Remove the Cap, and shine a flashlight down the Flue. Remove any bird nests, or other foreign material. 3) Check for evidences of excessive condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.
MAINTENANCE 8) Remove the Side Base Brick Panels and finally the Long Base Brick Panels. Remove Left & Right Side Base Brick Panels 13) Undo the pilot tube from the valve with a 7/16" spanner. INSTALLING VALVE 14) Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) spanner. 1) Attach the valve to the valve bracket with the 6 (m5x8 metric) screws provided. 15) Remove the Piezo igniter wire and push button assembly. 2) Reconnect the "gas out" flare fitting with an 11/16" spanner.
PARTS LIST Part # 1) 2) 9) 10) 11) 17) 24) 360-528 360-538 360-529 360-539 360-046 360-047 430-001 360-086 * 32) 902-296 33) 902-297 34) 902-298 Description P121 (SEE THRU) MAIN ASSEMBLY Door Assy Front - Tempered Door Assy Front - Ceramic (Optional) Door Assy Side - Tempered Door Assy Side - Ceramic (Optional) Nailing Strip - Top - Front Nailing Strip - Top - Side Standoff - Top Gasket - Relief Door Relief Door Assembly Part # Description Part # Description 135) 360-069 Heat Shield - Side 18
PARTS LIST Part # Description P131 (PIER) MAIN ASSEMBLY Part # Description Part # Description Door Assy Front - Tempered Door Assy Front - Ceramic (Optional) 141) 360-031 Column Finishing Trim 181) * Extension Trim - Pier 146) 360-035 Finishing Trim Door Assy Side - Tempered Door Assy Side- Ceramic (Optional) 149) 360-122 150) 360-123 151) 904-258 Magnet Bracket - Corner Magnet Bracket - Front Magnet 204) 360-940 206) 910-172 224) 360-942 Dec. Grill Front - Black (set) Fan Axial 240V Dec.
PARTS LIST Part # 1) 2) P121RC (RIGHT CORNER) MAIN ASSEMBLY Description 360-528 360-538 Door Assy Front - Tempered Door Assy Front - Ceramic (Optional) 360-529 360-539 Door Assy Side - Tempered Door Assy Side - Ceramic (Optional) 9) 360-046 10) 360-047 11) 430-001 780-013 17) 360-086 24) * Nailing Strip - Top - Front Nailing Strip - Top - Side Standoff - Top Standoff - Rear Gasket - Relief Door Relief Door Assembly 32) 902-296 33) 902-297 34) 902-298 Brick Panel - Base - Side Brick Panel - Base
PARTS LIST Part # 1) 2) P121LC (LEFT CORNER) MAIN ASSEMBLY Description 360-528 360-538 Door Assy Front - Tempered Door Assy Front - Ceramic (Optional) 360-529 360-539 Door Assy Side - Tempered Door Assy Side - Ceramic (Optional) 9) 360-046 10) 360-047 11) 430-001 Nailing Strip - Top - Front Nailing Strip - Top - Side Standoff - Top 17) 360-086 24) * Gasket - Relief Door Relief Door Assembly 32) 33) 34) 35) Brick Panel - Base - Side Brick Panel - Base - Front Brick Panel - Side Brick Panel - Fr
PARTS LIST P121/P121LC/P121RC/P131 BURNER ASSEMBLY & LOG SET 41) 42) 43) 44) Part # Description 360-930 904-326 904-327 904-328 904-329 Log Set Front Right Log Front Left Log Middle Left Log Middle Right Log 360-574/P 56) 360-378/P Valve Assembly Valve S.I.T.
NOTES _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ ____________
WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.