www.regency-fire.com ULTIMATE U38 Freestanding Gas Stove MODELS: U38-NG1 Natural Gas Owners & Installation Manual U38-LP1 Propane FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your buildFOR YOUR SAFETY ing. Do not store or use gasoline or other flammable vapors and Immediately call your gas supplier liquids in the vicinity of this or any other appliance. from a neighbour's phone.
WARNING HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Gas Stove by FIREPLACE PRODUCTS INTERNATIONAL LTD. The Regency® Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the flick of a switch. The models U38-NG1, and U38-LP1 of this series has been approved by Warnock Hersey for both safety and efficiency.
TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Copy of Safety Label .....................................................4 Operating Instructions ................................................21 Lighting Instructions.....................................................21 Shutdown Instructions .................................................21 First Fire ......................................................................21 Automatic Convection Fan Operation..........................
SAFETY LABEL This is a copy of the label that accompanies each ULTIMATE Freestanding Gas Stove. We have printed a copy of the contents here for your review. The safety label is located on the inside of the drop down pedestal door. NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.
INSTALLATION BEFORE YOU START Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following: INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC.
INSTALLATION 6) Test Gas Pressure. Refer to the "Gas Pipe Pressure Testing" section. 7) Install standard and optional features. Refer to the following sections where applicable. a. Log Set Installation b. Front Door Installation c. Louver Installation d. Wall Thermostat e.
INSTALLATION DRAFT HOOD VENTING This heater has a draft hood built in. It must not be altered, obstructed, or blocked in any way, and the unit must be installed so that the draft hood is in the same atmospheric pressure zone as the combustion air inlet to the burner. This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system. This heater is a vented appliance and must be connected to a chimney/flue in accordance with the installation codes.
INSTALLATION GAS CONNECTION The gas line can be rigid pipe, or to make installation easier, use a listed flexible connector if allowed by local codes. Copper may also be used if approved by local codes. The gas connection at the valve is 3/8" NPT. For minimum and maximum supply pressure see the System Data Table. System Data U38-1 with 40,000 BTU U38-NG1: For 0 to 2000 feet altitude U38-LP1: For 0 to 4500 feet alttitude Burner Inlet Orifice Sizes: Natural Gas Burner #31 Propane #50 Max.
INSTALLATION CONVERSION KIT# 731-969 FOR NG TO LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 3) Remove burner. See diagram below. 10) Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it. Each Kit contains one LPG Conversion Kit and one DC Sparker Kit. LPG Conversion Kit Contains: Qty.
INSTALLATION WARNING! Do not over tighten the screw. Recommended to grip the wrench by the short side. 17) Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit. 2) Remove the front control panel by unscrewing the 6 screws. 14) Verify that if the conversion is from NG to LPG, the screw must be reassembled with the red o-ring visible (Fig. 5).
INSTALLATION 6) Secure with screw. 11) Attach the Piezo Ignition Wire to the back of the DC Sparker box. 15) Attach the green ground wire. green ground wire 7) Reversing step 2 and secure the control panel back onto the stove pedestal with the screws. 12) The ground wire and DC Sparker ignition go through the hole on the heat shield. 16) Install the supplied battery into the DC Sparker Box by opening the battery compartment. NOTE: The battery in the DC Sparker Box will need to be replaced annually.
INSTALLATION CONVERSION TO LOWER BTU RATING THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION! Move Rear Log Pins forward to front holes. Natural Gas Conversion Kit 730-920 Contains: Qty. Part # Description 1 904-240 Burner Orifice #37 (NG) 1 918-034 Decal "Converted to 30,000 Btu" 1 918-033 Instruction Sheet Propane Conversion Kit 730-922 Contains: Qty.
INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. 2) Sprinkle the embers on the left and right sides of the firebox base.
INSTALLATION 5) Sprinkle some lava rock just in front of B) 02-56 on the burner holes. 8) Place Front Right Log E)02-45 on the two pins as shown. B)02-56 E)02-45 Lava Rock 6) Place Front Left Log C)02-44 onto the 2 front pins as shown. 9) Place the lava rock in the area between the left and right logs, leaving a space in the middle for log (F) 02-47. C)02-44 7) Place the Left Top Log D)02-46 on the pin on Log B)02-56 and on top of the cutout on Log A)02-65.
INSTALLATION 11) Place the notch in Center Log F)02-47 over Log E)02-45 and across the cutout on Log A)0265. G)02-48 E)02-45 F)02-47 A)02-65 Side View E)02-45 Bracket Notch Cutout 12) Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray. The bottom right edge of Log G)02-48 must sit snugly against the bracket 13) Test fire to ensure proper light off (make sure flame flows smoothly from one end of burner to the other.
INSTALLATION FRONT DOOR INSTALLATION (packaged separately) 1) Open the two side panels. LOUVER INSTALLATION 1) Attach the top & bottom louvers to the side stove panel using 2 screws per side. The smoke should be drawn into the draft hood. If the smoke is not drawn into the draft hood, turn the unit off and check for the cause of lack of draft. . 2) Slide the door onto the two hinge pins making sure the two pieces are flush together. See diagram 1. 3) Close the door.
INSTALLATION FINAL CHECK OPTIONAL WALL THERMOSTAT OPTIONAL REMOTE CONTROL A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve. Use table below to determine the maximum wire length: Use the Regency® Remote Control Kit approved for this unit. Use of other systems may void your warranty. Note: Preferable if the thermostat is installed on an interior wall.
INSTALLATION WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation. Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the three pieces of door glass are properly positioned. Never operate the appliance with any of the glass removed or with the door open.
OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS do not follow these instructions exactly, a fire or explosion may result causing property damage, mation consult a qualified installer, service agency or gas supplier. a pilot which must be lighted by hand, following the instructions below exactly. NG smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than on the floor.
OPERATING INSTRUCTIONS PILOT ADJUSTMENT AERATION ADJUSTMENT Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile and 1 around the thermocouple, and 1 flowing across the rear of the burner (it does not have to be touching the burner). The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.
MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always shut the valve off before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean brush as the logs are fragile and easily damaged. 2) Clean glass (never when unit is hot), appliance, louvers, and door with a damp cloth. Never use an abrasive cleaner.
MAINTENANCE Installing Glass 1) Install both center and side glass onto extrusions as per diagram. 2) Place glass assembly into door frame. 7) Put gasket glue on the retainers, but do not put glue on the screws. Replace the door gasket, the two ends butt tight together on the bottom edge of the door. To Remove U38-1 Fan: 8) Replace door on the stove and check the seal. 2) Remove all logs and the rear log support, then remove the 10 screws holding the access panel in place, see Diagram 1.
MAINTENANCE REMOVING VALVE If your valve requires maintenance or replacement, follow these instructions: NOTE: 9) Carefully lift the burner tray assembly out. Always shut off the gas supply before removing the valve. 1) Open front pedestal door and unhook chain. You may want to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn't scratch the paint. See diagram below. 5) Carefully remove the logs and lava rock.
PARTS LIST U38-1 MAIN ASSEMBLY Part # Description 9) 10) 560-920 560-921 560-922 560-055 730-034 Top/Bottom Gold Louver Assy Top/Bottom Brush Nickel Assy Top/Bottom Black Louver Assy Fan Access Door Gasket for Fan Access Door 11) 12) 730-517/P 910-331/P 910-794 Fan Assembly Fan Motor (120 Volt) Power Cord (120 Volt) 15) 16) 17) 18) * 730-039 904-257 560-025 Pedestal Assembly Pedestal Door Pedestal Door Magnet Pedestal Back 19) 20) 21) 23) 730-530 730-525 560-031 904-258 Short Side Panel Door A
PARTS LIST U38-1 BURNER & LOG ASSEMBLY Part # 51) 52) 53) 54) 55) 56) 57) 58) Description 910-241 910-190 904-586 910-373 910-372 908-646 650-220 910-330 Burner ON/OFF Switch (3-way) Piezo Ignitor & Nut Knob - Fan Control Switch Knob - Pilot Valve Extension Flame Adjusting Knob Control Panel Decal Control Panel Plate Fan Speed Control (120 V) 750-524/P 750-526/P 910-478 904-240 904-690 904-390 904-641 Valve Assembly - Natural Gas Valve Assembly - Propane Valve S.I.T.
PARTS LIST U38-1 DOOR ASSEMBLIES 101) 105) 106) 107) 108) 111) 112) 208) Part # Description 730-921 730-924 730-926 730-932 730-928 650-920 * 940-323/P 936-243 940-322/P * 750-015 940-325/P Brush Nickel Mitred Door - Complete Gold Mitred Door - Complete Black Mitred Door - Complete Gold Wrap Door - Complete Gold Panel Door - Complete Door Gasket Kit Ceramic Paper Side Glass Glass Gasket Centre Glass Door Frame Fibre Paper Door Glass Extrusion Wrap Glass *Not available as a replacement part.
NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _____________________________________
WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable.
Regency® fireplace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency® Product. See the inside back cover for details. Register your Regency® online at http://www.regency-fire.