P121 / P121LC / P121RC / P131 Zero Clearance Direct Vent Gas Fireplace STYLE See Thru Left Corner Right Corner Pier MODEL P121-NG1 Natural Gas P121LC-NG1 Natural Gas P121RC-NG1 Natural Gas P131-NG1 Natural Gas WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY. The P121/ P121LC/P121RC/P131 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The model P121/P121LC/P121RC/P131 has been approved by Warnock Hersey for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
TABLE OF CONTENTS Safety Label Safety Label ............................................................... 4 Installation Manufactured Mobile Home Requirements ................. 2 Important Message .................................................... 5 Before You Start ........................................................ 5 General Safety Information ......................................... 5 Installation Checklist .................................................. 5 Specifications ....................
SAFETY LABEL This is a copy of the label that accompanies each P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open. Copy of Safety Decal for P121/P121LC/P121RC/P131 NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS The Panorama P121/P121LC/P121RC/P131NG1 or P121/P121LC/P121RC/P131-LP1 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation.
INSTALLATION SPECIFICATIONS P121-1 See Thru Note: These units are non-load bearing.
INSTALLATION P121LC-1 Left Corner Unit Note: These units are non-load bearing.
INSTALLATION LOCATING YOUR GAS FIREPLACE 1) When selecting a location for your stove, ensure that the clearances are met as outlined on page 9. A) P121-1 See Thru 2) Provide adequate clearances for servicing. 3) The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete). This may be the floor, or raised up on a platform to enhance its visual impact.
INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated (refer to diagrams on page 8): Clearance to Combustibles from: Back 0" (0mm) Side 0" (0mm) Floor 0" (0mm) WARNING: Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions.
INSTALLATION FRAMING AND FINISHING 1) For ease of installation, frame your fireplace after it is positioned and the vent system is installed. Remember to install the top standoffs. See page 11 for assembly. Use 2x4's and frame to local building codes. CAUTION: Verify your fireplace dimensions, framing methods and finished wall facing details before framing. Determine the total thickness of facing material - drywall plus ceramic tiles, slate, etc.
INSTALLATION FACING & FINISHING REQUIREMENTS This fireplace is supplied with a 3" metal extension trim above the fireplace. The extension trim may be replaced if the framing is faced with a noncombustible material placed flush with the front and side face of the unit and extending from the top of the unit. (ie. tile, slate, etc.) UNIT ASSEMBLY PRIOR TO INSTALLATION The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position.
V E V M V B Vent terminal . F V V A G B C V A V B B V A K B H j N V Area where terminal is not permited A V 18" L A Note: - A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. - Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. - If the vent termination is accessible, a certified guard shall be installed.
INSTALLATION VENTING ARRANGEMENT - HORIZONTAL TERMINATIONS Regency Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P121-1/P121LC-1/P121RC-1/P131-1 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 12.
INSTALLATION SIMPSON DURA-VENT VENTING Horizontal or Vertical Terminations The Simpson Dura-Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized finish. We recommend using the galvanized finish for installation with the P1211/P121LC-1/P121RC-1/P131-1.
INSTALLATION VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (Propane & Natural Gas) The diagram below shows examples of horizontal termination arrangements using one, two, or three 90o elbows (two 45o elbows equal one 90o elbow). Note: 1) A maximum of three 90o elbows are permitted. 2) Minimum distance between elbows is 1 ft. (305mm). • • • • • Simpson Dura-Vent 4" inner diameter 6-5/8" outer diameter Maintain clearances to combustibles as listed on page 9.
INSTALLATION Horizontal Venting with Two (2) 90o Elbows Option A) B) C) D) E) F) 1' 2' 3' 4' 5' 6' V (305mm) Minimum (610mm) Minimum (914mm) Minimum (1.22m) Minimum (1.5m) Minimum (1.86m) Minimum H + H1 2' (610mm) Maximum 5' (1.5m) Maximum 8' (2.4m) Maximum 11' (3.35m) Maximum 14' (4.27m) Maximum 15' (4.5m) Maximum With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 15 feet total horizontal.
INSTALLATION VENTING ARRANGEMENTS - VERTICAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (Propane & Natural Gas) • • • • Vent must be supported at offsets Maintain clearances to combustibles as listed on page 9. Firestops are required at each floor level and whenever passing through a wall. Must use optional flue adapter when using Simpson Dura-Vent pipe (Part# 510-994). The P121-1/P121LC-1/P121RC-1/P131-1 is approved for a maximum 35 ft. (10.
INSTALLATION Vertical Venting with Two (2) 90o Elbows Option A) B) C) D) E) F) 1' 2' 3' 4' 5' 6' V (305mm) Minimum (610mm) Minimum (914mm) Minimum (1.22m) Minimum (1.5m) Minimum (1.86m) Minimum Vertical Venting with Two (2) 90o Elbows Option A) B) C) D) H 4' (1.22m) Maximum 6' (1.86m) Maximum 9' (2.7m) Maximum 12' (3.6m) Maximum 15' (4.5m) Maximum 17' (5.1m) Maximum With the above options, maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal.
INSTALLATION Vertical Venting with Three (3) 90o Elbows Option A) B) C) D) 2' 3' 4' 5' V + V1 (610mm) Minimum (914mm) Minimum (1.22m) Minimum (1.5m) Minimum H + H1 3' (914mm) Maximum 6' (1.86m) Maximum 9' (2.7m) Maximum 12' (3.6m) Maximum With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal. Please note minimum 1 foot between 90o elbows is required.
INSTALLATION VERTICAL TERMINATION 4) Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed. 1) Maintain the 1-1/4" clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation. Check pages 17-19 for the maximum vertical rise of the venting system and the maximum horizontal offset limitations.
INSTALLATION roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem. 7) Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails, slide storm collar over the pipe section and seal with a mastic. 8) Install the vertical termination cap by twistlocking it.
INSTALLATION CONVERSION KIT FROM NATURAL GAS TO PROPANE MODEL #730-969 FOR P121-1/P121LC-1/P121RC-1/P131-1 USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit Contains: Qty.
INSTALLATION P121/P121LC/P121RC/P131-NG1 System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: #31 Max. Input Rating 40,000 Btu/h Min. Input Rating 20,500 Btu/h For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1. The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point. When using copper or flex connectors use only approved fittings.
INSTALLATION 1) Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position. LOG INSTALLATION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. 2) Place Log 02-79 on the front right side of the burner. Ensure that the notches on the far right side of the log fit into the grate posts.
INSTALLATION Repeat step 3 on the opposite side of the burner. Repeat step 5 on the opposite side of the burner. 02-82 02-80 02-80 02-82 4) Embers should be placed in front of Log 02-79 and Log 02-80 and also down the middle between the logs as shown in the image below. 6) Place Log 02-81 on the middle right side of the burner. Ensure that the log fits over the 2nd grate post from the right. 02-81 Caution: Do NOT cover burner ports. 5) Place Log 02-82 on the middle left side of the burner.
INSTALLATION GLASS DOOR REMOVAL 1) Remove the 8 screws that secure the glass door. FINISHING TRIM LOUVERS & GRILLS 1) Slide the Side Finishing Trim up into the slot in the top flange of the fireplace. Push tight against the magnet at the base of the unit. 1) Attach the screws provided to the top left and right corners. NOTE: Do not tighten the screw entirely, ensure that some room is left to be able to hang the grill or louver over the screw. Slide Trim into slot.
INSTALLATION Option 1: REMOTE CONTROL Option 2: WALL SWITCH Option 3: WALL THERMOSTAT Can be used with Option 2 or 3 but not both. Can be used with Option 1 or 3 but not both. Can be used with Option 1 or 2 but not both. Use the Regency Remote Control Kit approved 1) Run the supplied 15' of wire through the for this unit. Use of other systems may void your back gas inlet opening. Be careful not to warranty. damage wire.
INSTALLATION WIRING DIAGRAM No electrical power supply is required for the gas control to operate. 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. A terminal block is provided on the left hand side of the unit. A Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. 28 three wire power cord can also be used and plugged into a suitable receptacle. (Do not cut the ground terminal off under any circumstances.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 6) Rotate the flame height regulator to adjust the flame height higher or lower. CAUTION: Carbon will be produced if air shutter is closed too much. SHUTDOWN PROCEDURE Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.
OPERATING INSTRUCTIONS Pilot Flame: While the pilot flame is on it can make a very slight "whisper" sound. Gas Control Valve: As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve. Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.
MAINTENANCE 2) Remove the Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material. 3) Check for evidences of excessive condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.
MAINTENANCE 8) Remove the Side Base Brick Panels and finally the Long Base Brick Panels. Remove Left & Right Side Base Brick Panels 13) Undo the pilot tube from the valve with a 7/16" wrench. INSTALLING VALVE 14) Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench. 1) Attach the valve to the valve bracket with the 6 (m5x8 metric) screws provided. 15) Remove the Piezo igniter wire and push button assembly. 2) Reconnect the "gas out" flare fitting with an 11/16" wrench.
MAINTENANCE FAN REPLACEMENT 1) Shut off power. 6) Replace fan. 2) Remove top louvers. 7) Repeat for opposite side/corner. 3) Unplug power wires. 8) Reverse steps 1 - 5 for installation. 4) Remove 4 screws securing fan to mounting bracket. 9) To remove the thermodisc, located at the back center of the unit, slide the thermodisc/cover assembly away from the bracket clip on the under side of the firebox. Reverse for installation. Ensure that no wires will touch hot surfaces.
PARTS LIST P121-1 (SEE THRU) MAIN ASSEMBLY Part # 1) 2) 9) 10) 11) 17) 24) 360-528 360-538 Description Door Assy Front - Tempered Door Assy Front - Ceramic (Optional) 360-529 360-539 Door Assy Side - Tempered Door Assy Side - Ceramic (Optional) 360-046 360-047 430-001 360-086 * Nailing Strip - Top - Front Nailing Strip - Top - Side Standoff - Top Gasket - Relief Door Relief Door Assembly 32) 902-296 33) 902-297 34) 902-298 Brick Panel - Base - Front Brick Panel - Base - Side Brick Panel - Side 98
PARTS LIST P131-1 (PIER) MAIN ASSEMBLY Part # Description Part # Description Part # Description Door Assy Front - Tempered Door Assy Front - Ceramic (Optional) 141) 360-031 Column Finishing Trim 181) * Extension Trim - Pier 146) 360-035 Finishing Trim Door Assy Side - Tempered Door Assy Side- Ceramic (Optional) 149) 360-122 150) 360-123 151) 904-258 Magnet Bracket - Corner Magnet Bracket - Front Magnet 204) 360-940 206) 910-171 224) 360-942 Dec. Grill Front - Black (set) Fan Axial 115V Dec.
PARTS LIST P121RC-1 (RIGHT CORNER) MAIN ASSEMBLY Part # 1) 2) 360-528 360-538 360-529 360-539 Description Door Assy Front - Tempered Door Assy Front - Ceramic (Optional) Door Assy Side - Tempered Door Assy Side - Ceramic (Optional) 9) 360-046 10) 360-047 11) 430-001 780-013 17) 360-086 24) * Nailing Strip - Top - Front Nailing Strip - Top - Side Standoff - Top Standoff - Rear Gasket - Relief Door Relief Door Assembly 32) 902-296 33) 902-297 34) 902-298 Brick Panel - Base - Side Brick Panel - Base -
PARTS LIST P121LC-1 (LEFT CORNER) MAIN ASSEMBLY Part # Description 1) 360-528 360-538 Door Assy Front - Tempered Door Assy Front - Ceramic (Optional) 2) 360-529 360-539 Door Assy Side - Tempered Door Assy Side - Ceramic (Optional) 9) 360-046 10) 360-047 11) 430-001 Nailing Strip - Top - Front Nailing Strip - Top - Side Standoff - Top 17) 360-086 24) * Gasket - Relief Door Relief Door Assembly 32) 33) 34) 35) Brick Panel - Base - Side Brick Panel - Base - Front Brick Panel - Side Brick Panel - F
PARTS LIST P121/P121LC/P121RC/P131-1 BURNER ASSEMBLY & LOG SET 41) 42) 43) 44) Part # Description 360-930 904-326 904-327 904-328 904-329 Log Set Front Right Log Front Left Log Middle Left Log Middle Right Log 360-574/P 56) 360-378/P Valve Assembly Valve S.I.T.
WARRANTY Regency Fireplace Products, are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
Regency fireplace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product. See the inside back cover for details. Register your Regency online at http://www.regency-fire.