3. PROTECTION SYSTEM
This amplifier uses a very complex protection system. If an error occurs, the amplifier
switches to standby or off mode and prints an error code to the display.
In this way, the protection system is able to avoid a series of potential damages to the
amplifier, but there is no reason to operate carelessly.
3.1. Errors in Power On mode:
Code Legend
17 average plate voltage too high
18 IG2 too high
19 plate current too high
20 grid RF too high
21 problem with output relay contact
22 screen current too high
23 HV < 350V for more than 120 ms
24 HV > 3300V or HV < 1500V
25 low air for > 90 s
3.2. Errors in Standby mode:
Code Legend
33 plate current > 25mA
34 high voltage > 3300V or high voltage < 1500V
35 temperature > 115°C
36 problem with output relay contact
37 G1 screen current
38 low air for > 90 s
39 problem in low voltage supply
40 drive power > 0.44W
41 average plate voltage > 480V
42 G2 screen current > 5mA