3 PROTECTION SYSTEM 16
ALPIN100 Manual © Copyright 2010 by Reimesch Kommunikationssysteme GmbH
3.3. Errors in Operate mode:
Code Legend
49 plate current > 1.2 A
50 problem in low voltage supply
51 low air for > 90 s
52 HV > 3300V or HV < 1500V
3.4. Errors in TX/RX mode:
Code Legend
64 problem with
output relay contact
66 output relay contact switch 5ms problem
67 output relay contact switch 5ms problem
68 Grid RF and PANT are not ok
3.5. Warnings in Operate mode:
Besides those errors there are some warnings in the Operate mode. The amplifier shows a
flashing warning message and/or will switch to Standby mode.
Message Legend Action
REFLECTED PWR Reflected power > 350W Standby mode
DRIVE TOO HIGH
Drive power > 90W for less than 5 s
Drive power > 90W for more than 5s
Drive power > 120W
Warning
Standby mode
Standby mode
SCREEN CURRENT Screen current > 80mA for more than 1s Standby mode
PLATE CURRENT
Plate current > 700mA
Plate current > 800mA for more than 2s
Warning
Standby mode
OVERHEATING
Temperature > 97°C ( 207° F)
Temperature > 115°C ( 239° F)
Warning
Standby mode
ARC FAULT Recognized arc Standby mode
GRID CURRENT Grid current too high Standby mode