User Manual
25
Note: Due to variaons in program material, it is impossible to produce a perfectly reliable standby circuit.
Bass rich music or eects will consistently trigger our standby circuit whilst content that is low in volume and
possesses lile or no bass cannot be relied upon to trip the standby funcon.
Alternavely, the user has the opon to leave the unit in the normal operaon mode at all mes by selecng
the ALWAYS ON posion of the power mode switch. Leaving a REL on, produces the best sonic performance
and the most reliable operaon. In this mode, the unit will not enter standby regardless of whether or not
there is acvity at the input. Using this seng ensures that the 212/SX is ready to react instantaneously to
bass transients, whether in music or lms.
The REL 212/SX is shipped in the ALWAYS ON mode.
During inial setup, use the REL this way. Aer inial setup, if you wish to employ the standby mode, simply
move the power mode switch into the up posion to STANDBY.
Model Power Draw at Standby Power Draw at Idle
212/SX > 0.5 Was 40 Was