Datasheet
0410 | 183
4
This issue replaces all previous issues. Availability, errors and specifications subject to change without notice.
Sockets
MRC series
S3-B
Socket for 11-pin standard relay according to IEC 67-I-18b
29.75
68
38
8 7 6 5
22212432
10 2
A2 31 1 A1
0 1 1 2
12
4
9
34 14
311
7 5
1
RELECO S3-B
ø
8.2
ø
5.3
24
6
8
M3
19
1.3
32°44’
32°44’
1
2
3
4
5
6
7
8
9
10
11
ø
7
)
24
(
(
22
)
56
(
21
)
8
42
10
)
12
(
)
32
(
(
A2
)
(
A1
)
)
11
(
1
11
(
31
)
(
14
)
3
(
34
)
9
(
14
)
)
A1
(
)
11
(
)
31
(
)
A2
(
)
34
(
9
(
32
)
(
24
)
(
21
)
(
22
)
)
12
(
10
11
1
2
3 4
5
6
7
8
29.75
68
38
8 7 6 5
22212432
10 2
A2 31 1 A1
0 1 1 2
12
4
9
34 14
311
7 5
1
RELECO S3-B
ø
8.2
ø
5.3
24
6
8
M3
S2-B
Type S3-B
3-pole, 1 connection level
Coding ring optional
Integrated retaining clip and labelling space
Rated current 10 A
Specifications
Rated load 10 A / 250 V
Insulation Test voltage V rms / 1 min
All terminals/DIN rail 2,5 kV
– Terminal/terminal 2,5 kV
Cross-section of connecting wire
– Single-wire 4 mm
2
or 2 x 2,5 mm
2
– Multi-wire 22 - 14 AWG
Max. screw torque 1,2 Nm
Screw dimensions M3, Pozi, slot
Integrated retaining clip/plastic for relay series C3
Labelling space detachable
Connection label 1… 11; DIN/EN
Mounting DIN rail T35 or mounting plate
Ambient temperature -40 (no ice).…60 ºC /-40 ... 80 °C
Associated, plug-in 11-pin MRC relays C3-A, C3-G, C3-T, C3-X, C3-M, C3-R,
Suitable for holding the Releco coding ring C3-E, C3-N, C3-S
For coding the relay and the socket.
Accessories
Coding ring, blue set: S3-BC
Packaging unit: 5 pcs
Retaining spring, steel S3-C, S3-CT (with Timecube)
Dimensions [mm]
Connection diagram
Lloyd´s
Technical approvals, conformities
EN 60947-1, EN 61810-1
05_Sockets_4_1.indd 183 17.03.10 13:40