User Manual
MAINTENANCE OF THE BOILER
To maintain your steam cleaner in good condition and to ensure consistent performance, we rec-
ommend that you clean the boiler once or twice a year depending on the hardness of the water.
CLEANING INSTRUCTIONS
ATTENTION: Before draining the boiler, please make sure that the machine is depressurized and
cool. Ensure that it is also disconnected from the power source.
1. Take off the drainage cap at the bottom of the machine using a coin.
2. Completely unscrew the boiler brass drainage nut from the boiler, using a 20 mm hexago-
nal key (19).
3. To clean the boiler, we recommend using a descaling powder that can be purchased from
www.reliablecorporation.com
4. Add the descaling powder with a mixture of warm water through the bottom of the boiler.
5. Let the mixture of warm water and powder sit for 24 hours.
6. Rinse thoroughly to ensure that all of the descaling powder has been removed
7. After cleaning, twist close the drainage nut and replace the cap.
NOTE: if you see that the water that is coming out from the boiler is full of dirt/limestone, we
suggest that you repeat this operation more frequently, perhaps three to four times per year.
TECHNICAL DESCRIPTION
120V ~ Power 1750W
Cold water tank capacity 3,1L
Boiler capacity 1,6L
Working pressure 6 bar
Continuous steam system (CSS) Yes
Steam Regulations 3
Safety valve Yes
Hot water injection Yes
Limestone Magnetic Filter Yes
Certiļ¬cations cETLus