Instructions / Assembly

10
Specifications and Parts List
Model # /
Configuration
15114A
30114A
20A
6
-
Cir
30A
6
-
Cir
50A
6
-
Cir
30A
8
-
Cir
50A
8
-
Cir
30A
10
-
Cir
50A
10
-
Cir
Max. Watts 1875 3750 5000 7500 12500 7500 12500 7500 12500
Max. single-pole circuits 4 6 8 10
Max. double-pole and
multi-wire circuits
0 1 4 5
# of handle ties provided
n/a
1
2
Max. combined loads
Amps @ 125 VAC
15 30 40 60 100 60 100 60 100
Max. combined loads
Amps @ 250VAC
n/a 20 30 50 30 50 30 50
Max. load/circuit from
generator
15 amps 4-15 amps & 2-20 amps
6-15 amps & 2-
20 amps
6-15 amps & 4-
20 amps
Max. load/circuit from
load center
20 amps
Power inlet, NEMA*
configuration - Cord
Connected Models
5-15 L5-30 L14-20
L14-30
CS6365
L14-30
CS6365
L14-30
CS6365
Minimum cord gauge
14
10
12
10 6 10 6 10 6
No. of conductors (wires)
3-wire 4-wire
Conduit length
18"
Conduit, trade-size
diameter
1/2" 3/4" 1"
Optional Power Inlet
Catalog #
PB15 PB31 PB20 PB30 PB50 PB30 PB50 PB30 PB50
Shipping w
eight
9 lbs.
10 lbs.
13 lbs.
Dimensions (H x W x D) 7 1/2" x 7" x 4 1/2" 13 1/4"x 7"x 4"
*National Electrical Manufacturer's Association Note: If your model is not listed here, please
refer to the supplemental installation instructions
packaged with that unit.
Transfer Switch Parts List
3
Description
Part#
Circuit breaker, 15A 6291
Circuit breaker, 20A 6292
Wattmeter, 30A (3750 watts)
Current Transformer (3750 6294
Switch, 30A SPDT
Power inlet, 20A
Power inlet, 30A 6702
Handle tie
Power Inlet Filler Panel 6271