Instructions / Assembly

INSTRUCTIONS FOR THE RELIANCE Panel/Link
®
- TT Series
Generator-ready Main Breaker Panel (Horizontal On/Off)
THE RELIANCE PANEL/LINK
®
TRANSFER PANEL IS NOT FOR “DO-IT-YOURSELF”
INSTALLATION. It must be installed by a qualified electrician thoroughly familiar with all
applicable electrical and building codes.
This Reliance Panel/Link
®
Transfer Panel is the combination of a main load center and a transfer
mechanism for providing an alternate input from a supplemental power source, such as a
generator. In the event of a power outage, it is designed to provide a safe and simple method of
powering some or all of the branch circuits in the panel from a portable generator. The unique
factory-installed mechanical interlock between the circuit breakers feeding the panel bus prevents
feedback by prohibiting the Main breaker and the Generator breaker from being in the “ON”
position at the same time.
Generally, a small portable generator will most likely lack sufficient capacity to power a large
number of circuits at the same time. The Reliance Panel/Link Transfer Panel allows you to power
selectively any number or combination of branch circuits by manually alternating between those
circuits that are to be energized, up to the capacity of the generator.
KEY COMPONENTS OF THE PANEL/LINK
®
TRANSFER PANEL
MAIN (UTILITY) CIRCUIT BREAKER. This is the large, centered circuit breaker that controls the
supply of power from the utility line to the branch circuits along the panel bus. It will generally be
“ON” when utility power is present.
GENERATOR CIRCUIT BREAKER. This is the double-pole circuit breaker located nearest to the
Main breaker. This controls the supply of power from the alternate source, such as a generator. It
will remain “OFF” when the Main circuit breaker is “ON”.
BRANCH CIRCUIT BREAKERS. The remaining circuit breakers in the panel (furnished by the
installer) are the branch circuit breakers, and control the supply of power from the panel bus to the
individual branch circuits. These will generally be in the “ON” position when the Main circuit breaker
is “ON” and utility power is present, and selectively “ON” or “OFF” when generator power is present.
BREAKER INTERLOCK MECHANISM. This is the mechanical linkage located between the Main
circuit breaker and the Generator circuit breaker. It prevents both of these breakers from being in
the “ON” position simultaneously, and is the safety feature that prevents feedback between the utility
source and the generator.
INSTALLATION
DANGER! HAZARDOUS VOLTAGE. DISCONNECT ALL ELECTRICAL SUPPLY SOURCES
BEFORE INSTALLATION AND WHEN SERVICING CONNECTED EQUIPMENT OR
CIRCUITS.
This panel is installed in a manner similar to a main load center, and in accordance with all
applicable electrical codes. See the accompanying installation instructions and the wiring diagram
on the inside cover of the panel.