Lithium Battery SDS Safety Data Sheet
relionbattery.com
+
1.803.547.7288
844.385.9840
9868 Harrisburg Road
Fort Mill, SC 29707, US
© 2017 Relion Battery, LLC. All rights reserved. Relion Battery is not liable for damages that may result from any information provided in or omitted from this publication, under any circumstances. Relion Battery reserves the right to make adjustments to this publication at any time, without notice or obligation.
Safety Data Sheet 10.24.17
SECTION COMPOSITION/INFORMATION
ON INGREDIENTS
Chemical Characterization: Mixture
Chemical
Composition
CAS No. EC# Weight (%)
Ferrous Phosphate Litium 15365-14-7 476-700-9 38.09
Carbon Black 133-86-4 215-609-9 0.62
Rubber, styrene-
butadiene, fume
61789-96-6 612-382-1 0.34
Polyvinylidene
fluoride resin
24937-79-9 607-458-6 1.04
Graphite 7782-42-5 231-955-3 20.10
Phosphate (1-),
hexafluoro-, lithium
21324-40-3 244-334-7 1.10
Copper 744-50-8 231-159-6 9.22
Aluminium 7429-9-5 231-072-3 4.00
SECTION FIRST AID MEASURES
Description of First Aid Measures
General Information: No special measures required.
After Eye Contact
Flush eyes with plenty of water for several minutes while holding
eyelids open. Get medical attention if irritation persists.
After Skin Contact
Remove contaminated clothing and shoes. Immediately wash with
water and soap, rinse thoroughly. Wash clothing and shoes before
reuse. If irritation occurs, get medical attention.
After Inhalation
Remove victim to non exposed area. Administer artificial respiration
if breathing is diicult. Seek medical attention.
After Swallowing
Do not induce vomiting. Get medical attention.
Personal protective equipment for first-aid responders: No data
available
Most important symptoms/eects, acute and delayed: No data
available
Indication of immediate medical attention and special
treatment needs: No data available
SECTION ACCIDENTAL RELEASE MEASURES
Personal Precautions: Wear protective equipment. Keep
unprotected persons away. Ensure adequate ventilation.
Protective Equipment: No data available.
Emergency Procedures: Remove ignition sources, evacuate area.
Sweep up using a method that does not generate dust. Collect as
much of the spilled material as possible, place the spilled material
into a suitable container for disposal. Keep spilled material out of
sewers, ditches and bodies of water.
Environmental Precautions: Do not allow material to be released
into the environment without proper governmental permits.
Methods and Materials for Containment and Cleaning Up:
All waste must refer to the United Nations, the national and local
regulations for disposal.
See Section 7 for information on safe handling.
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
SECTION FIRE FIGHTING MEASURES
Suitable extinguishing media:
Use extinguishing agent suitable for local conditions and the
surrounding environment, such as dry powder, CO2.
Unsuitable extinguishing media: No data available.
Specific Hazards Arising from the Chemical:
Special hazards arising from the substance or mixture
Battery may burst and release hazardous decomposition products
when exposed to a fire situation. Lithium ion batteries contain
flammable electrolytes that may vent, ignite and spark when
subjected to high temperature (>150°C (302°F), when damaged or
abused (e.g.) mechanical damage or electrical overcharging); may
burn rapidly with flare-burning eect; may ignite other batteries in
close proximity.
Specific protective actions for fire-fighters:
Protective equipment: wear self-contained respirator. Wear fully
protective impervious suit.